5kVA & 6kVA Models: Distribution Model

Utility Input Connection

Output Load Connections

NEMA L14-30P 10.5ft (3.2m) cord

NEMA L6-30R, NEMA L14-30R, (4) 5-20R (T-Slot)

PD5-001

2.7

COMMUNICATION OPTIONS

A.

Liebert IntelliSlot ® Communication 1.

The UPS shall include one Liebert IntelliSlot communication port to allow the operator to field-install an optional Liebert IntelliSlot communication card. A Liebert IntelliSlot card may be installed during any state of UPS operation (On, Standby or Off states). Available Liebert IntelliSlot options are described below. 2. Liebert Intellislot RDU101 Communications Card: The optional Liebert Intellislot RDU101 card shall deliver SNMP and web access to the UPS via 10/100 Mb/s ethernet port. This card shall enable remote or local field upgrades of the SNMP firmware, and managed device firmware and configuration updates. This card shall support environmental monitoring via Liebert SN Sensors. 3. Liebert IntelliSlot Relay Interface Card (IS-RELAY): The optional Liebert IntelliSlot Relay Interface Card shall provide contact closure for remote monitoring of alarm conditions in the UPS, delivering signals for On Battery, On Bypass, Low Battery, Summary Alarm, UPS Fault and On UPS. The contacts shall be rated for 24VAC or 24VDC at 1A. Connections shall be to a terminal block connector with cable provided by the end user. B. Terminal Block Connections: The UPS shall contain on the rear panel a terminal block to provide low voltage signals for On Battery, Low Battery, Any Mode Shutdown and Battery Mode Shutdown. 1. Any-mode Shutdown: The purpose of Any-Mode Shutdown shall be to shut down the UPS output by turning Off the rectifier, inverter and bypass so that there is no power to the loads. 2. Any-Mode Shutdown can be operated locally and remotely, as described as follows: a. Local Any-mode Shutdown can be entered from the battery mode shutdown device on the back of the unit. b. Remote Any-mode Shutdown can be initiated by a battery mode shutdown button mounted at a remote location. 3. Remote Power Off shall be performed either by NO or NC contact of Any-mode Shutdown, depending on the settings in the configuration program. 4. A current-limited source (+12VDC, 50mA) shall be available from the UPS. 5. The connection to the UPS for remote connection shall be via terminal block connector.

263353-14

Made with FlippingBook Online newsletter maker