Community College of Allegheny County OCS Security Camera System Pittsburgh, PA
2) Attenuation test results for horizontal links shall be less than 2.0 dB. Attenuation test results shall be less than those calculated according to equation in TIA-568-C.1.
C. Data for each measurement shall be documented. Data for submittals shall be printed in a summary report that is formatted similar to Table 10.1 in BICSI TDMM, or transferred from the instrument to the computer, saved as text files, and printed and submitted. D. Remove and replace cabling where test results indicate that it does not comply with specified requirements. E. End-to-end cabling will be considered defective if it does not pass tests and inspections. F. Prepare test and inspection reports.
END OF SECTION 271523