CURB COUNTERFLASHING
MEMBRANE COATED METAL
1" CANT OPTIONAL
TREATED WOOD NAILER
SPECIFIED MEMBRANE STRIP
MECHANICALLY ATTACH 4" O.C. STAGGERED 1"
HEAT WELDED LAPS
SPECIFIED MEMBRANE
SPECIFIED ADHESIVE
ROOF DECK
INSULATION (WHERE SPECIFIED)
SPECIFIED FASTENER AND PLATE
NOTES: 1) SPACING AND FASTENING OF NAILERS SHALL CONFORM TO FACTORY MUTUAL LOSS PREVENTION DATA SHEET I-49.
SCALE:
SHEET TITLE:
NTS
CURB FLASHING USING MEMBRANE COATED METAL
DRAWING No.:
26