Community College of Allegheny County Pittsburgh, Pennsylvania
2022 Library Roofing Project
SECTION 07540 THERMOPLASTIC MEMBRANE ROOFING
PART 1 - GENERAL
1.01
RELATED DOCUMENTS
A. Drawings and contract documents, including Section 01010 SUMMARY OF WORK, apply to this section.
1.02
SUMMARY
A. This section includes the materials and application procedures for a Fully Adhered Ketone Ethylene Ester Fleeceback (KEE FB) Single-Ply Thermoplastic Roofing System.
1.03
RELATED SECTIONS INCLUDE THE FOLLOWING:
A.
Section 01010 Summary of Work
B.
Section 01025 Measurement and Payment
C.
Section 01700 Contract Closeout
D.
Section 02060 Demolition
E.
Section 13280 Asbestos Abatement
1.04
DEFINITIONS
A. Tremply KEE Roof Membrane is a thermoplastic single ply roof membrane that is comprised of an elastomeric TremPly Ketone Ethylene Ester (KEE). Tremply KEE Roof Membrane is 60 mil thickness; smooth and fleeceback versions and meets LEED requirements.
B.
Roofing Terminology: 1.
Refer to ASTM D 1079 and glossary of NRCA's "The NRCA Roofing and Waterproofing Manual" for definition of terms related to roofing work in this Section.
1.05
PERFORMANCE REQUIREMENTS
A.
General: 1.
Install a watertight, single ply thermoplastic roofing system with compatible components that will not permit the passage of liquid water and will withstand wind loads, thermally induced movement, and exposure to weather.
07540-1 THERMOPLASTIC MEMBRANE ROOFING
February 2022
Made with FlippingBook - Online Brochure Maker