SmartJack V4.0 Installation
Proximity Sensor Wiring Locate the Proximity Sensor located on the motor drive gear next to the gearbox. Wire directly to the Control Box. See wiring requirements below. Proximity Sensor Connections Proximity (Color) Control Box Brown 24H Blue 24N Black 350
Proximity Switch
Wire Requirements Use 14-18 AWG wire or other suitable formats following local codes. Use wire sizes and formats to accommodate the length of wire run from the motor/gear assembly to the Control Box.
Home Limit Proximity Sensor Wiring Wire the Home Limit Switch previously installed on the door section and wall to the Control Box
Home Limit Switch Connections Home Switch (Color) Control Box Brown 24H Blue 24N Black 330
-Warning- NEVER run Proximity Sensor, Home Limit Switch, Photoeyes or any other low voltage wires in the same conduit as high voltage wiring (motor/brake). It will cause signal interference.
Control Station Wiring For wiring 3 button wall stations, keyswitches and other controls *4-wire setup ONLY applicable with one remote pushbutton station. **5-wire setup preferred to allow for more than one remote pushbutton station to run stop buttons in series from station to station
3- Button Stations ( * 4-wire Configuration)
3- Button Stations ( ** 5-wire Configuration) Open/Close Common 24H Close 240 Open 220 Stop Common 260 Stop 261 Remove Jumper on 260 and 261
Common
260 240 220
Close Open Stop
261 Remove Jumper on 260 and 261
Use 14-18 AWG wire
9
800-233-1487
Fax: (218) 751-6551
Carwashdoors.com
Made with FlippingBook - Online catalogs