HuFriedyGroup | Step by Step Guide | GB

HuFriedyGroup Infection Prevention Guidelines

Do you know if your office is following the proper infection prevention protocol? Instrument processing is a key part of any office infection control program and must be performed properly to help ensure patient safety.

Instrument Processing Area

The dental practice should have a designated central processing area divided physically, or at least spatially, into separate areas for: 1. Receiving, Cleaning & Decontamination 2. Preparation & Packaging 3. Sterilization 4. Storage

Sterilization

Sterile Cassette Storage

Automated Handpiece Cleaner (optional)

Waste Management For regular, sharps and biomedical waste

Instrument Washer

Rinsing

Cleaning Recessed or Countertop Ultrasonic

Wrapping Drawers

Drying Drawers (optional)

Operatory Prep Area

Cleaning, Rinsing, Drying (optional)

Soiled

Sterile

Instrument Processing Guidelines • Work practice controls should be used to minimise handling of loose, contaminated instruments during transportation to the central processing area.

• Dental team members should be trained to use work practices that prevent contamination of clean areas. For example: Sterilised and clean supplies should be stored away from a contaminated area.

IMS™ Infinity Series™ Cassette

For example: Instruments should be transported in a closed container.

1. Receiving, Cleaning & Decontamination

• Cleaning and disinfection should precede the sterilisation process. It should involve removal of debris as well as organic and inorganic contamination. • If visible debris is not removed, it will interfere with microbial inactivation and can compromise the disinfection or sterilisation process. • Puncture/chemical-resistant utility gloves (such as HuFriedyGroup Lilac™ Utility Gloves ) should be worn when handling contaminated instruments and when performing instrument cleaning and decontamination procedures. > Use automated cleaning equipment (e.g., ultrasonic cleaner or washer-disinfector) to increase productivity and decrease worker exposure to blood and body fluids. • Appropriate PPE (mask, protective eyewear and protective clothing) should be worn when splashing or spraying is anticipated during cleaning. • Visibly clean instruments might not be enough to ensure quality of your cleaning protocol. In order to know if your instruments have passed the first step, HuFriedyGroup recommends to use Cleaning Monitors , designed to monitor the efficacy of the cleaning process when using washer- disinfectors and ultrasonic cleaners.

2. Preparation & Packaging

All instruments must be completely dry before packaging. • After cleaning, critical & semi-critical instruments should be inspected for remaining debris. Hinged instruments, such as pliers, bone rongeur forceps, scissors and needle holders should always be lubricated. HuFriedyGroup offers the following for all of your lubrication and maintenance needs: > Shine reNEW Instrument Wipes: Remove stain, rust, corrosion and restore the luster to stainless steel and tungsten carbide instruments, as well as stainless steel cassettes. Shine reNEW eliminates the need for abrasive scrubs and is quick and simple to use. > ILS (Instrument Lubricant Spray) : Used to help keep hinged instruments moving freely. Applied before sterilisation and does not dry out during sterilisation. • Before sterilisation, instruments and other patient-care items should be assembled into sets (cassettes) or trays, and wrapped, packaged, or placed into a container system for sterilisation. Packages should be labeled with the date.

3. Sterilisation

Surface Disinfectant Cleaning and Disinfection are key to maintaining a safe and healthy practice environment, and disinfecting clinical surfaces is frequently performed with staff turning over rooms after each and every patient, as well as the decontamination area after each decontamination cycle. HuFriedyGroup Bactryl™ Wipes and Spray will make it easy for dental practices since it is safe on all hard, non-porous healthcare surfaces, including glass, plastics, stainless steel and vinyl. Wear gloves and other PPE to prevent occupational exposure to infectious agents and hazardous chemicals during surface disinfecting. 4. Storage • Store sterile items in covered or closed cabinets. Never store sterile items above a steriliser. • Examine all sterilised packs before opening for use to ensure the barrier wrap has not been compromised during storage. > Reclean, repack and re-sterilise any instrument package that has been compromised. • Place packages correctly and loosely into the steriliser so the sterilant can properly reach all contents. • A Bowie-Dick Test Pack is designed to detect the presence of residual air in pre-vacuum steam sterilizers operating at 134°C for 3.5 minutes. Daily, place the test pack on the bottom shelf, over the drain closest to the door, in an otherwise empty chamber. • Biological monitoring, also known as spore testing, determine whether microorganisms are destroyed from the steam sterilization process. It should be performed weekly. • Mechanical and chemical monitors should be used according to the manufacturer’s instructions to ensure the effectiveness of the sterilisation process. > Each load should be monitored with mechanical and chemical indicators. • A chemical indicator should be placed on the inside of each instrument package to be sterilised. > If the internal indicator is not visible from the outside , another chemical indicator should be added to the outside of package.

Free Call: 00800 48 37 43 39 | Free Fax: 00800 48 37 43 40 E-Mail: info@hu-friedy.eu | Website: HuFriedyGroup.eu HuFriedyGroupEurope

Hu-Friedy Mfg. Co. LLC. • European Headquarters • Lyoner Str. 9 • 60528 Frankfurt am Main, Germany • HuFriedyGroup.eu All company and product names are trademarks of Hu-Friedy Mfg. Co. LLC, its affiliates or related companies, unless otherwise noted. ©202 4 Hu-Friedy Mfg. Co., LLC All rights reserved. IMS-235GB/ 0224

HuFriedyGroup Infection Prevention Products

Cleaning and Care Products Ultrasonic Cleaning Solutions Enzymax Liquid Packets (40 per box)

IMS-1222 IMS-1226 IMS-1226P IMS-1229

Enzymax Liquid Gallon Bottle Enzymax Liquid Gallon Pump Enzymax Spray Gel, 24 fl. oz

Cleaning Monitors Washer-Disinfector Cleaning Monitor, 50 pcs

IMS-1200W IMS-1200U IMS-1200H

Ultrasonic Cleaning Monitor, 50 pcs Cleaning Monitor Holder, 1 each

Stain and Rust Remover Shine reNEW Instrument Wipes (20 wipe container)

IMS-1455

Instrument Lubricant Spray Instrument Lubricant Spray, 8 oz

ILS

Lilac Utility Gloves Small, Size 7

40-060 40-062 40-064 40-066

Medium, Size 8 Large, Size 9

Extra Large, Size 10

Surface Disinfectant Bactryl™ Spray (1000 ml - 4 units)

500046 500047

Bactryl™ Wipes (Tub with 110 wipes - 6 units)

Sterilisation Products Bagette Pouches 57 x 102 mm, rubber dam clamps or burs, 200 pcs 70 x 229 mm, 1 handpiece or 1-3 hand instruments, 200 pcs 89 x 229 mm, loose instrument pouch. Fits 3-6 hand instruments, 200 pcs 133 x 254 mm, 1 handpiece or multiple instruments, 200 pcs 190 x 330 mm, for Exam 5-instrument cassettes, 100 pcs 254 x 356 mm, for Small 8-10 instrument cassettes, 100 pcs 305 x 432 mm, for Large 16-20 instrument cassettes, 100 pcs 330 x 508 mm, oral Surgery Cassette; IMOSX Large Custom Cassette, 100 pcs Autoclave Wraps 600 x 600 mm, for DIN and Container Cassettes, 500 sheets 600 x 600 mm, for DIN and Container Cassettes, 100 sheets 375 x 375 mm, for 1/4 DIN Cassettes, 1000 sheets 375 x 375 mm, for 1/4 DIN Cassettes, 100 sheets 500 x 500 mm for 1/2 DIN Cassettes, 500 sheets 500 x 500 mm, for 1/2 DIN Cassettes, 100 sheets Bonded Double Wrap 508 x 508 mm, for 1/2 DIN Cassettes, 480 sheets 380 x 380 mm, for 1/4 DIN Cassettes, 480 sheets 610 x 610 mm, for DIN and Container Cassettes, 240 sheets DIN Container 1 Container Cassette - dimensions: 312 x 190 x 50 mm 1 Container Cassette - dimensions: 312 x 190 x 65 mm 2 Container Cassette - dimensions: 312 x 190 x 100 mm 3 Container Cassette - dimensions: 312 x 190 x 135 mm Chemical Indicators Type 1 IMS™ Steam Sterilization Indicators, 250 pcs/pack Type 5 IMS™ Steam Sterilization Integrators, 100 pcs/pack Type 5 STEAMPlus™ Integrators, 100 pcs/pack Type 5 STEAMPlus™ Integrators, 250 pcs/pack Type 5 STEAMPlus™ Integrators, 1000 pcs/pack EU AirView™ II Bowie-Dick Test Pack, 127 x 95 x 16 mm, 30 pcs/pack IMS™ Monitor Tape (18 x 55 mm) Ortho IMS-1243 Restorative IMS-1247 Surgery IMS-1248 Amalgam IMS-1251 C&B IMS-1252 Cement IMS-1253 Composite IMS-1254 Endo IMS-1255 Exam IMS-1256 Extraction IMS-1257 Perio IMS-1258 Prophy Pedo Grey Orange Purple Yellow Red Green Blue Black Lead Free Blank

IMS-1346

IMS-1347

IMS-1236

IMS-1348

IMS-1237

IMS-1238

IMS-1239

IMS-1345

IMS-1210M

IMS-1210MH

IMS-1211M IMS-1211MH

IMS-1212

IMS-1212MH

IMS-2220 IMS-2215 IMS-2224

IMDINCO0M IMDINCO1M IMDINCO2M IMDINCO3M

IMS-1240 IMS-1241

SSI-100 SSI-250

SSI-1000 MBD030E

IMS-1259 IMS-1260 IMS-1262 IMS-1263 IMS-1264 IMS-1265 IMS-1266 IMS-1267 IMS-1268 IMS-1269 IMS-1461 IMS-1270 IMS-1270H

Tape Dispenser, holds up to 9 rolls Mini Tape Dispenser, holds up to 4 rolls

Biological Indicator ConFirm™ 10 Steam Biological Indicators, 25 pcs/pack

C10BI25

ConFirm™ 10 Digital Incubator

C10SK

Standard Incubator

NDB-060-E

ConFirm™ Record Keeper Booklet

CRK02

Implementing an infection prevention and instrument processing protocol that follows the European and National Guidelines helps your practice provide a safer and more comfortable environment for your staff and patients. Enhance instrument integrity by the use of the HuFriedyGroup Instrument Management System (IMS). The IMS Solution allows clinicians to move instruments from cleaning to chairside in Cassettes, without manual handling instruments.

IMS INSTRUMENT MANAGEMENT SYSTEM

To know more about our product portfolio, download our Infection Prevention Catalogue!

Free Call: 00800 48 37 43 39 | Free Fax: 00800 48 37 43 40 E-Mail: info@hu-friedy.eu | Website: HuFriedyGroup.eu HuFriedyGroupEurope

Hu-Friedy Mfg. Co. LLC. • European Headquarters • Lyoner Str. 9 • 60528 Frankfurt am Main, Germany • HuFriedyGroup.eu All company and product names are trademarks of Hu-Friedy Mfg. Co. LLC, its affiliates or related companies, unless otherwise noted. ©202 4 Hu-Friedy Mfg. Co., LLC All rights reserved. IMS-235GB/ 0224

Page 1 Page 2

www.hufriedygroup.eu