FMM User Manual

ENGLISH

7.2.1 TRAVEL LIMITS Verify that power to your system in ON.

8.0

ACCESSORIES

8.1

STANDARD ACCESSORIES

• Use the jog switch to manually position the crosshead to a location that is approximately at the center position of the column. • Position the Upper crosshead travel limit to approximately 3 inches above the crosshead’s center column position. Make sure the crosshead travel limit is tightened. • Position the Lower crosshead travel limit to approximately 3 inches below the crosshead’s center column position. Make sure the crosshead travel limit is tightened. • Use the UP jog key to slowly move the crosshead upward until it comes into contact with the Upper limit. The crosshead should stop automatically. If it does not, contact your Starrett Service Representative immediately. • Use the DOWN jog key to slowly move the crosshead downward until it comes into contact with the Lower limit. The crosshead should stop automatically. If it does not, contact your Starrett Service Representative immediately. 7.2.2 EMERGENCY STOP SWITCH Verify that the Emergency Stop Switch is in the ON position. • Press the jog switch. The crosshead should not move since the Emergency Stop is in the down (ON) position. • Press and release the Emergency Stop Switch so that the switch is UP and in the OFF position. • Press the jog switch. The crosshead should move freely. 7.2.3 FUSE REPLACEMENT The FMM test frame uses two 2A Slo-Blo fuses (5 x 20mm). The fuse compartment is located in the Power Entry Module. WARNING Electrical Hazard. Make sure to shut all power to your FMM force measurement system to OFF. Dangerous voltage may cause personal injury. • Turn the power switch on the back panel of the FMM frame to the OFF position. • Disconnect the power cord from the power source. • Replace the fuse with the same type and size as the original. • Remove the protective cap that covers the fuse compartment. • Grasp and remove the fuse holder. • Remove the fuse. • Install a new fuse into the holder. The replacement fuse needs to be the factory-specified type and rating as original. An incorrect fuse may damage the electrical circuits inside your machine. • Re-insert the fuse holder. • Place the protect cap back onto the fuse compartment. • Reconnect the power cable. • Turn power to the systemONby placing the power switch in the ONposition.

ORDER NO.

DESCRIPTION

Base Clevis Kit, M6 thread, for FMM-110, FMM-110X, FMM-330 and FMM-330X

SPK-CLEVIS-S

SPK-CLEVIS-L Base Clevis Kit, M12 thread, for FMM-550 and FMM-550X MLX-RINGS-S Included in Base Clevis Kits (above), locking ring, M24 MLX-PIN-S Included in Base Clevis Kits (above), grip pin L1-SPANNER Included in Base Clevis Kits (above), spanner wrench L1-BASE-M Base Adapter Plate, Metric, M4, M6, M10 and M12 holes SPK-FG-BLOCK Force Gage Mounting Block, for Starrett DFG and DFC

8.2

OPTIONAL ACCESSORIES

ORDER NO. DESCRIPTION SPK-BLC BLOCK BLC Mounting Block, for Starrett BLC Load Cells L1-USB Cable, USB Mini D-sub A to B L1-RS232 Cable, RS-232, 6 ft. (2m) length L1-CONTROL Cable, Control when using DFC Force Controller L1-BASE-US

Base Adapter Plate, Imperial, #10-32, 5/16-18, 1/4-28, 1/2-20 holes

L1-FMMCLIP

Anti-skid Mounting Clips

FORCE GAGE MOUNTING ADAPTERS MLX-FG-CHAT Mounting Plate, for using Chatillon® Force Gages MLX-FG-MARK Mounting Plate, for using Mark-10® Force Gages MLX-FG-MECM Mounting Plate, for using Mecmesin® Force Gages MLX-FG-IMAD Mounting Plate, for using Imada® Force Gages MLX-FG-SHIM Mounting Plate, for using Shimpo® Force Gages

24 PKG08813-UMFMM

Made with FlippingBook - professional solution for displaying marketing and sales documents online