240405-Climate Catalogue-Digital

CLIMATE BOAT / MARINE AIR CONDITIONERS

Dometic DCU Self-contained High-capacity Compact A/C

Engineered to harness and maximize the impressive performance of environmentally safe R410A refrigerant. These units offer direct expansion operation in a compact, low-profile unit with a seawater-cooled condenser and choice of controls. Compact design • High-velocity fully insulated blowers are rotatable • Patented design increases cooling capacity and dehumidification • Condenser coil’s cupronickel-encased copper coil provides maximum heat transfer and high resistance to corrosion • Evaporator coil employs an enhanced fin design and rifled copper tubing to provide maximum capacity

18,000 – 27,000 BTU/h

115 V/60 Hz/1-PH 230 V/60 Hz/1-PH 220–240 V/50 Hz/1-PH 380 V/50 Hz/3-PH

MODEL 1

DCU18

DCU27

Capacity 2 (BTU/h)

18,000

27,000

Voltage (V)

115

230

220

230

220

Cycle 3 (Hz) /Phase (Ph)

60/1

60/1

50/1

60/1

50/1

Full Load Amps (FLA) Cool (A)

11.1

6.4

5.7

8

7.6

Full Load Amps (FLA) Heat (A)

15.1

8.3

7

11.2

11

Full Load Amps (FLA) Blower (A)

1.93

1.15

1.15

1.64

1.64

Locked Rotor Amps (LRA) (A)

66

32

26

58.3

60

Max. Circuit Breaker (A)

45

20

20

45

40

Min. Circuit Ampacity (A)

27

13

13

27

24

410A

410A

Refrigerant Type

Height-Coil 4 (in/mm)

14 / 356

18 / 458

Height-Blower 4 (in/mm)

15.5 / 394

19.25 / 489

Height-Compressor 4 (in/mm)

n / a

n / a

Width 4 (in/mm)

21 / 534

24.75 / 629

Depth (in/mm)

12 / 305

15.25 / 388

Min. Supply Duct Size (in/mm)

7 / 178

8 / 204

1

1

Quantity-Duct Connections

Min. Supply Air Grille Size (in 2 /cm 2 )

100 / 646

140 / 904

Min. Return Air Grille Size (in 2 /cm 2 )

200 / 1291

240 / 1549

Seawater Inlet Connection (in/mm)

0.625 / 16

0.625 / 16

Net Weight 5 (lbs/kg)

64 / 29.1

69.45 / 31.6

70 / 31.8

120 / 54.5

Gross Weight 5 (lbs/kg)

73 / 33.2

81 / 36.8

82 / 37.2

130 / 59

1. To complete the model numbers for a specific voltage/cycle/phase, add a ‘-1161’ for 115V/60Hz/1-Phase, or ‘-2361’ for 230V/60Hz/1-Phase, followed by ‘-410A’ (e.g. ‘DCU27-2361-410A’). 2. TU and electrical data are based on a 45°F/7.2°C evaporator and 100°F/37.8°C condenser in cool mode, and a 45°F/7.2°C evaporator and 130°F/54.4°C condenser in heat mode. 3. 60Hz units must not operate at 50 Hz and 50 Hz units must not operate at 60Hz unless data plate states otherwise 4. All dimensions ± 0.30 in/8 mm. 5. All weights ± 10%.