240405-Climate Catalogue-Digital

CLIMATE BOAT / MARINE AIR CONDITIONERS

Dometic DEGX Marine Condenser

MODEL 1

DEGX6

DEGX8

DEGX10

DEGX12

DEGX16

Capacity 2 (BTU/h)

6,000

8,000

10,000

12,000

16,000

Voltage (V)

115

230

115

230

115

230

115

230

115

230

Cycle 3 /Phase (Hz/Ph)

60/1

50–60/1

60/1

50–60/1

60/1

60/1

50–60/1

60/1

50–60/1

50–60/1

Full Load (FLA) Cool (A)

3.6

1.6

4.2

2.2

5.2

2.6

6.6

3.2

8.7

4.7

Full Load (FLA) Heat (A)

4.8

2.2

5.6

3.0

7.0

3.5

9.1

4.4

11.8

6.2

Locked Rotor (LRA) (A)

25.5

10.0

28.0

15.0

42

21

50.5

26.7

61

26.9

Max. Circuit Breaker (A)

15

5

20

10

25

15

30

15

40

20

Min. Circuit Ampacity (A)

10

5

12

6

16

8

19

10

24

13

R410A

R410A

R410A

R410A

R410A

Refrigerant Type

Seawater Inlet Connection (in/mm)

0.625 / 16

0.625 / 16

0.625 / 16

0.625 / 16

0.625 / 16

cupronickel tube

cupronickel tube

cupronickel tube

cupronickel tube

cupronickel tube

Seawater Connection Type

Refrigerant Line Connection Discharge (in) Refrigerant Line Connection Suction (in)

1/4

1/4

1/4

1/4

1/4

3/8

3/8

3/8

3/8

1/2

Net Weight 4 (lbs/kg)

43/20

43/20

45/20

47/21

49/22

50/23

Gross Weight 4 (lbs/kg)

50/23

50/23

52/24

51/23

54/24

56/26

57/26

Max Height 5 (in/mm)

12 / 305

12 / 305

13 / 331

13 / 331

14.1 / 359

Width 5 (in/mm)

13.3 / 338

13.3 / 338

13.3 / 338

13.3 / 338

13.3 / 338

Depth Without Elec. Box (in/mm)

13.3 / 338

13.3 / 338

13.3 / 338

13.3 / 338

13.3 / 338

Depth With Elec. Box (in/mm)

15.1 / 384

15.1 / 384

15.1 / 384

15.1 / 384

15.1 / 384

Height-Electrical Box (in/mm)

8.75 / 223

8.75 / 223

8.75 / 223

8.75 / 223

8.75 / 223

Width-Electrical Box (in/mm)

6.5 / 166

6.5 / 166

6.5 / 166

6.5 / 166

6.5 / 166

Depth-Electrical Box (in/mm)

2.63 / 67

2.63 / 67

2.63 / 67

2.63 / 67

2.63 / 67

1. For dual frequency units 6K through 16K, to complete the model numbers for a specific voltage/cycle/phase, add a ‘-410’, then ‘1171’ for 115 V/50–60 Hz/1-Phase, or -2371’ for 230 V/50–60 Hz/1-Phase (e.g. ‘DEG12-410 2371’). For ranges 24K through 72K, add a ‘-410’, ‘-2251’ for 220–240 V/50 Hz/1-Phase, or ‘-2361’ for 230 V/60 Hz/1-Phase (e.g. ‘DEU24-410 2361’). 2. BTU and electrical data are based on a 45 °F/7.2 °C evaporator and 100 °F/37.8 °C condenser in cool mode, and a 45 °F/7.2 °C evaporator and 130 °F/54.4 °C condenser in heat mode. 3. For ranges 24K through 72K, 60 Hz units must not operate at 50 Hz and 50 Hz units must not operate at 60 Hz unless data plate says otherwise. 4. All weights ± 10%. 5 All dimensions ± 0.30 in/8 mm.

Dimensions DEGX6–16

18 — DOMETIC.COM

Made with FlippingBook Ebook Creator