240405-Climate Catalogue-Digital

Dometic DEUX Marine Condenser

MODEL 1

DEUX48

DEUX60

DEUX72

Capacity 2 (BTU/h)

48,000

60,000

72,000

Voltage (V)

230 240 230 460 380 230 240 230 380 460 230 220 230 380 460

Cycle 3 /Phase (Hz/Ph)

60/1 50/1 60/3 60/3 50/3 60/1 50/1 60/3 50/3 60/3 60/1 50/1 60/3 50/3 60/3

Full Load (FLA) Cool (A)

10.9 12.10 8.2 5.3 3.8 13.0 14.4 10.2 5.6 5.29 16.6 21.5 11.2 7.1 5.94

Full Load (FLA) Heat (A)

16.2 18.0 10.90 6.6 5.0 20.2 21.4 12.7 7.6 6.6 24.0 29.1 14.8 8.8 7.40

Locked Rotor (LRA) (A)

105 102.5 95 60 45 150 130 120 70 60 145 130 120 87 70

Max. Circuit Breaker (A)

70 70 45 30 20 80 80 55 30 30 100 100 60 40 30

Min. Circuit Ampacity (A)

43 42 28

17

13

48 48 33

19

17

57 57 34 24

19

R410A

R410A

R410A

Refrigerant Type

Seawater Inlet Connection (in/mm)

0.625/16

0.625/16

0.625/16

cupronickel tube

cupronickel tube

cupronickel tube

Seawater Connection Type

Refrigerant Line Connection Discharge (in) Refrigerant Line Connection Suction (in)

3/8

3/8

3/8

3/4

3/4

3/4

Net Weight 4 (lbs/kg)

115 / 52

147 / 67

147 / 67

Gross Weight 4 (lbs/kg)

150 / 68

176 / 80

183 / 83 187 / 84 183 / 83 180 / 82 181 / 82

Max Height 5 (in/mm)

18.5 / 470

20 / 508

20 / 508

Width 5 (in/mm)

16 / 407

16 / 407

16 / 407

Depth Without Elec. Box 5 (in/mm)

16 / 407

16 / 407

16 / 407

Depth With Elec. Box 5 (in/mm)

18.8 / 478

18.8 / 478

18.8 / 478

Height Electrical Box (in/mm)

13.25 / 337

13.25 / 337

13.25 / 337

Width Electrical Box (in/mm)

7.75 / 197

7.75 / 197

7.75 / 197

Depth Electrical Box (in/mm)

3.75 / 96

3.75 / 96

3.75 / 96

1. For dual frequency units 6K through 16K, to complete the model numbers for a specific voltage/cycle/phase, add a ‘-410’, then ‘1171’ for 115 V/50–60 Hz/1-Phase, or -2371’ for 230 V/50–60 Hz/1-Phase (e.g. ‘DEG12-410 2371’). For ranges 24K through 72K, add a ‘-410’, ‘-2251’ for 220–240 V/50 Hz/1-Phase, or ‘-2361’ for 230 V/60 Hz/1-Phase (e.g. ‘DEU24-410 2361’). 2. BTU and electrical data are based on a 45 °F/7.2 °C evaporator and 100 °F/37.8 °C condenser in cool mode, and a 45 °F/7.2 °C evaporator and 130 °F/54.4 °C condenser in heat mode. 3. For ranges 24K through 72K, 60 Hz units must not operate at 50 Hz and 50 Hz units must not operate at 60Hz unless data plate says otherwise. 4. All weights ± 10%. 5. All dimensions ± 0.30 in/8 mm.

MOBILE LIVING MADE EASY — 19

Made with FlippingBook Ebook Creator