Dometic DEUX Marine Condenser
MODEL 1
DEUX48
DEUX60
DEUX72
Capacity 2 (BTU/h)
48,000
60,000
72,000
Voltage (V)
230 240 230 460 380 230 240 230 380 460 230 220 230 380 460
Cycle 3 /Phase (Hz/Ph)
60/1 50/1 60/3 60/3 50/3 60/1 50/1 60/3 50/3 60/3 60/1 50/1 60/3 50/3 60/3
Full Load (FLA) Cool (A)
10.9 12.10 8.2 5.3 3.8 13.0 14.4 10.2 5.6 5.29 16.6 21.5 11.2 7.1 5.94
Full Load (FLA) Heat (A)
16.2 18.0 10.90 6.6 5.0 20.2 21.4 12.7 7.6 6.6 24.0 29.1 14.8 8.8 7.40
Locked Rotor (LRA) (A)
105 102.5 95 60 45 150 130 120 70 60 145 130 120 87 70
Max. Circuit Breaker (A)
70 70 45 30 20 80 80 55 30 30 100 100 60 40 30
Min. Circuit Ampacity (A)
43 42 28
17
13
48 48 33
19
17
57 57 34 24
19
R410A
R410A
R410A
Refrigerant Type
Seawater Inlet Connection (in/mm)
0.625/16
0.625/16
0.625/16
cupronickel tube
cupronickel tube
cupronickel tube
Seawater Connection Type
Refrigerant Line Connection Discharge (in) Refrigerant Line Connection Suction (in)
3/8
3/8
3/8
3/4
3/4
3/4
Net Weight 4 (lbs/kg)
115 / 52
147 / 67
147 / 67
Gross Weight 4 (lbs/kg)
150 / 68
176 / 80
183 / 83 187 / 84 183 / 83 180 / 82 181 / 82
Max Height 5 (in/mm)
18.5 / 470
20 / 508
20 / 508
Width 5 (in/mm)
16 / 407
16 / 407
16 / 407
Depth Without Elec. Box 5 (in/mm)
16 / 407
16 / 407
16 / 407
Depth With Elec. Box 5 (in/mm)
18.8 / 478
18.8 / 478
18.8 / 478
Height Electrical Box (in/mm)
13.25 / 337
13.25 / 337
13.25 / 337
Width Electrical Box (in/mm)
7.75 / 197
7.75 / 197
7.75 / 197
Depth Electrical Box (in/mm)
3.75 / 96
3.75 / 96
3.75 / 96
1. For dual frequency units 6K through 16K, to complete the model numbers for a specific voltage/cycle/phase, add a ‘-410’, then ‘1171’ for 115 V/50–60 Hz/1-Phase, or -2371’ for 230 V/50–60 Hz/1-Phase (e.g. ‘DEG12-410 2371’). For ranges 24K through 72K, add a ‘-410’, ‘-2251’ for 220–240 V/50 Hz/1-Phase, or ‘-2361’ for 230 V/60 Hz/1-Phase (e.g. ‘DEU24-410 2361’). 2. BTU and electrical data are based on a 45 °F/7.2 °C evaporator and 100 °F/37.8 °C condenser in cool mode, and a 45 °F/7.2 °C evaporator and 130 °F/54.4 °C condenser in heat mode. 3. For ranges 24K through 72K, 60 Hz units must not operate at 50 Hz and 50 Hz units must not operate at 60Hz unless data plate says otherwise. 4. All weights ± 10%. 5. All dimensions ± 0.30 in/8 mm.
MOBILE LIVING MADE EASY — 19