SPECIFICATIONS FOR TURBO TITANIUM SERIES SELF-CONTAINED A/C
Model 1
DTGX6
DTGX8
DTGX10
DTGX12
DTGX16
Capacity (BTU/h)
6000
8000
10000
12000
16000
Voltage (VAC)
115
230
230
115
230
230
115
230
230
115
230
230
115
230
230
Cycle (Hz)
60/1
60/1
50/1
60/1
60/1
50/1
60/1
60/1
50/1
60/1
60/1
50/1
60/1
60/1
50/1
/Phase (Ph) Full Load Amps (FLA) Cool (A) Full Load Amps (FLA) Heat (A) Full Load Amps (FLA)
4.4
2.0
1.9
5.5
2.9
3.2
6.3
3.2
3.1
7.7
3.8
4.4
10.3
5.5
4.7
5.8
2.6
2.4
6.9
3.7
3.8
8.1
4.1
3.9
10.2
5.0
5.2
13.4
7.0
6.0
0.8
0.4
0.4
1.3
0.7
0.8
1.1
0.6
0.5
1.1
0.6
0.5
1.6
0.8
0.6
Blower (A) Locked Rotor Amps (LRA) Max. Circuit Breaker (A) Min. Circuit
25.5
10.0
10.9
28
15.0
16.8
41.5
21.0
24.4
50.5
26.7
28.4
61.0
26.9
29.4
8
21
12
12
29
15
15
35
19
18
44
23
21
18
9
10
5
4
12
7
7
17
9
8
20
11
10
25
13
12
Ampacity (A) Refrigerant Type Max Height (in/cm)
410A
410A
410A
410A
410A
11.4/29.0
11.6/29.5
12.2/31.0
12.2/31.0
13.3/33.8
17.8/45.2
17.8/45.2
20.4/51.8
20.4/51.8
21.5/54.6
Max Width
10.7/27.2
10.7/27.2
12.4/31.5
12.4/31.5
13.3/33.8
Max Depth
Min. Duct Size Dia. (in/cm)
4/10.16
5/12.7
6/15.2
6/15.2
7/17.8
32/206
48/310
60/387
70/452
80/516
Min. Supply Air Grille (sq in/cm) Min. Return Air Grille (sq in/cm) Net Weight (lbs/kg)
64/413
80/516
100/645
130/839
160/1032
58.0/26.3
38.0/17.2
38.0/17.2
41.0/18.6
43.0/19.5
53.0/24.0
52.0/23.6
53.0/24.0
53.0/24.0
57.0/25.9
Gross Weight (lbs/kg)
44.0/20.0
44.0/20.0
48.0/21.8
50.0/22.7
62.0/28.1
61.0/27.7
62.0/28.1
62.0/28.1
66.0/29.9
67.0/30.4
1) BTU and electrical data are based on a 45 degreeF/7.2degreeC evaporator and 100 degree F/37.8 degree C condenser in cool mode, and a 45 F/7.2 C evaporator and 130 degree F/54.4 degree C condenser in heat. 2) Electric box is remote mounted up to 34” (86cm) away from compressor. E-box dimensions are 2.7” (6.9cm) x 6.5” (16.5cm) x 8.8” (22.4cm).
dometic.com
8 — DOMETIC.COM
Made with FlippingBook Ebook Creator