Fit Product Guide 2025 - Drawer & Door Systems

Technical Information

Space Needed to Open the Door

T= 16 17 18 19 20 21 22 23 24 25 26 K=3 A= 0.5 0.7 0.9 1.2 1.5 1.8 2.4 3.7 5.1 6.5 7.8 K=4 A= 0.5 0.7 0.9 1.2 1.5 1.8 2.1 2.7 4.1 5.5 6.8 K=5 A= 0.5 0.7 0.9 1.2 1.5 1.8 2.1 2.6 3.1 4.1 5.4 K=6 A= 0.5 0.7 0.9 1.2 1.5 1.8 2.1 2.5 3.0 3.5 4.4

T= 16 17 18 19 20 21 22 23 24 25 26 K=3 L= 0.0 0.0 0.0 0.0 0.2 0.5 0.8 1.1 1.4 1.7 1.9 K=4 L= 0.0 0.0 0.3 0.6 0.9 1.2 1.4 1.7 2.0 2.3 2.6 K=5 L= 1.1 1.3 1.6 1.8 2.1 2.3 2.6 2.9 3.1 3.4 3.6 K=6 L= 2.0 2.3 2.5 2.8 3.1 3.3 3.6 3.8 4.1 4.3 4.6

The above values are calculated on the assumption that the doors have square edges. They are reduced if the doors have radiussed edges.

Projection of the Door Projection of the door from the cabinet side at the max. opening. The figures are based on a straight arm hinge, H=0 mm thickness of mounting plate and K value = 3 mm.

“C” Value With this formula you can obtain the max. thickness of the moulded door that can be opened without touching adjacent carcass sides, doors or walls, whilst bearing in mind the above L-K-T values.

C = 20 + K + A