Fit Product Guide 2025 - Drawer & Door Systems

Technical Information

Space Needed to Open the Door

T= 16 18 20 22 24 25 26 27 28

K=3

A=

0.0 0.0 0.0 0.0 0.0 0.10 0.40 0.75 1.20

K=4

A=

0.0 0.0 0.0 0.0 0.0 0.15 0.45 0.85 1.35

K=5

A=

0.0 0.0 0.0 0.0 0.0 0.20 0.50 0.95 120° 1.70 0.0 0.0 0.0 0.0 0.0 0.25 0.60 1.10 120° 1.95 0.0 0.0 0.0 0.0 0.0 0.30 0.70 1.30 110° 2.30

K=6

A=

K=7

A=

K=8

A=

0.0 0.0 0.0 0.0 0.0 0.35 0.85 120° 1.70 0.0 0.0 0.0 0.0 0.15 0.55 1.20 110° 2.15

110° 2.80 92° 3.90

K=9

A=

The above values are calculated on the assumption that the doors have square edges. They are reduced if the doors have radiussed edges.

Projection of the Door

“C” Value For spaces with removable components. Opening with lateral door protrusion equal to 5.5 mm with a hinge with straight arm, H=0 mounting plate and K=3 mm.

155° opening K from 3 to 8mm 13.5mm deep cup

K=4

1.5

6mm negative projection at 90° (with mounting plate)

209