ASSEMBLY INSTRUCTION - RJF™
Important note: - Can be assembled with all standard RJ45 cordset. - No tool required for assembly. - Choose your coding on plug side during the assembly. The standard coding on receptacle side is A. To change this coding use the removal tool. Please refer to page 99.
Recommend Torque value:
Extender
Body
Plastic Gland Metal Gland
Hex-nut
RJF 6
/ /
5.0 Nm 7.5 Nm 5.0 Nm 10.0 Nm
3.0 Nm
/
/ / / /
Plug
RJF 6M
/
10.0 Nm
RJF 2 PE RJF 2 PEM
5.0 Nm 7.5 Nm
3.0 Nm
/
/ /
10.0 Nm
Receptacle
RJF 7
/
/
/ /
10.2 to 10.7 Nm 10.2 to 10.7 Nm
RJF 7 PE RJF 7 PEM
5.0 Nm 7.5 Nm
5.0 Nm 10.0 Nm
3.0 Nm
/
10.0 Nm 10.2 to 10.7 Nm
Assembly video
See our assembly video on youtube : www.youtube.com\AmphenolSocapex
- Amphenol RJ Field Assembly - Rugged RJ45 connector
Amphenol SOCAPEX
Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex