ASSEMBLY INSTRUCTION - RJF™

Important note: - Can be assembled with all standard RJ45 cordset. - No tool required for assembly. - Choose your coding on plug side during the assembly. The standard coding on receptacle side is A. To change this coding use the removal tool. Please refer to page 99.

Recommend Torque value:

Extender

Body

Plastic Gland Metal Gland

Hex-nut

RJF 6

/ /

5.0 Nm 7.5 Nm 5.0 Nm 10.0 Nm

3.0 Nm

/

/ / / /

Plug

RJF 6M

/

10.0 Nm

RJF 2 PE RJF 2 PEM

5.0 Nm 7.5 Nm

3.0 Nm

/

/ /

10.0 Nm

Receptacle

RJF 7

/

/

/ /

10.2 to 10.7 Nm 10.2 to 10.7 Nm

RJF 7 PE RJF 7 PEM

5.0 Nm 7.5 Nm

5.0 Nm 10.0 Nm

3.0 Nm

/

10.0 Nm 10.2 to 10.7 Nm