910132_PTS_GK Brochure

ABC-150 The ABC-150 was originally developed to support the design and development of the drivetrain and subsystems of the GM Impact, the first modern electric car. All Webasto power cycling systems are equipped with a real-time clock on the system’s control board that enables measurement of Ah and kWh during cycling. The ABC-150 offers power up to 125kW, with a voltage range of 8 to 445VDC and a current range of ±530ADC. The ABC-150 is now the worldwide standard for the testing of advanced batteries, fuel cells, capacitors and other alternative energy technologies in the automotive, aerospace, stationary power and defense industries.

Technical Specifications

ABC-150

AC Voltage

3 Phase, 240VAC

AC Voltage Tolerance

+10%/-15% 335 Amps

AC Current Frequency

60Hz ±2Hz (50Hz ±2Hz available)

Requires 150KVA external isolation transformer (240Vrms secondary)

Isolation Transformer

Power Factor

>0.99

Harmonic Distortion

< 3% THD; IEEE 519 Compliant

Power efficiency DC Voltage Max DC Current Max DC Power Max

95% 445V

±265A

±125kW 0-35 °C 0-60 °C

Operating environment - temperature Storage environment - temperature Operating environment - Humidity

0-90% Noncondensing

Weight

1,400 lbs (635 kg)

Dimensions

46” W x 55” H x 26” D (117cm W x 140cm H x 65cm D)

Performance Data Control Interface / Output data sampling

Local Control / CAN 33ms / RS-232 100ms

Control Software Options

LabView; C++ and visual basic, Remote operation system (ROS)

Rise time voltage - step (0-400v) Rise time voltage - step (0-265a)

5.98ms 1.375ms

Slew rate voltage Slew rate current Slew rate power

66.89V/ms 192.73A/ms 165.22kW/ms

Current ripple - independent & parallel mode

<0.058Arms / <0.38Arms

Operating Range Configuration

Voltage (Vdc)

Current (Adc)

Power (kW)

+8 to +420

-320 to +265 -160 to +160

-125 to +125

Independent

+420 to +435 +435 to +445

-70 to +70 -40 to +40

-90 to +90

+8 to +420

-530 to +530 -160 to +160

-125 to +125

Parallel

+420 to +435 +435 to +445

-70 to +70 -40 to +40

-90 to +90

Accuracy & Resolution Measurement

Accuracy (±)

Resolution

Voltage

0.1% full scale 0.1% full scale

20mV 20mA

Current Independent (2 channels)

12

*Ask us about our power curves