Gustav Klein test systems
MI-TS-3871 Standard
MI-TS-3871-ol overload
I-TS-3872 Standard
Power rating in kW
250, 320, 400, 500, 650
250, 320, 400, 500
300, 600
Power overload capability performance
Max. DC output voltage in V
1000, 1200
1000
2x 750, 1500
Voltage with center point
± 1000 (750 V) ± 1000 (1500 V) ± 2000 (750 V) 1 (1500 V) 2 (750 V) 2 Systems max. 1200 kW
± 1000 ± 1200
± 1000 ± 1200
Current range in A (per channel)
2 oder 4
2 oder 4
Number of DC channels
2 oder 4 Channels max. 650 kW max. ± 2400 A (2 Chan.) max. ± 4800 A (4 Chan.) 2 oder 4 Channels max. 650 kW max. ± 2400 A (2 Chan.) max. ± 4800 A (4 Chan.)
2 oder 4 Channels max. 500 kW
Parallel switching capability (flexible)
max. ± 2400 A (2 Chan.) max. ± 4800 A (4 Chan.) 2 oder 4 Channels max. 500 kW max. ± 2400 A (2 Chan.) max. ± 4800 A (4 Chan.)
max. ± 2000 A (1500 V) max. ± 4000 A (750 V)
2 Systems max. 1200 kW max. ± 4000 A
Parallel switching capability (rigid)
IP20, IP21, IP23, IP54
IP20, IP21, IP23, IP54
IP54
Available protection classes
Air cooling
Water cooling
CAN, Modbus TCP, Ethernet, VNC Profibus, Profinet, EtherCAT, LabVIEW, Matlab/Simulink
CAN, Modbus TCP, Ethernet, VNC Profibus, Profinet, EtherCAT, LabVIEW, Matlab/Simulink
CAN, Modbus TCP, Ethernet, VNC
Communication interfaces (standard) Communication interfaces (optional)
Profibus, Profinet, EtherCAT
Not available
Standard
Optional
15