General technical data I-TS-3870 / I-TS-3870-ol AC mains voltage / AC mains frequency

380 / 400 / 440 / 480 / 690 V ± 10 %, 3-phase, PE, 50 / 60 Hz ± 5 %

Measurement accuracy

Voltage: 16 Bit ADC // Current: 16 Bit ADC Voltage: 0.1 % fs // Current: 0.1 % fs

Control accuracy

Ripple voltage / current Voltage tolerance dynamic (0-100 % INom in 3 ms) Short circuit performance

≤ 0.1 % eff. fs Battery tester < 3 % fs Battery emulator < 1 % fs

Short circuit proof: Systems up to 600 A: Icw: 3 kA Systems with 1000 A: Icw: 8 kA Systems with 1200 A: Icw: 15 kA

Permissible environmental conditions: Storage as per EN 60721-3-1 Transport as per EN 60721-3-2 Operation as per EN 60721-3-3

1K21 / 1M11, +5 to +40 °C 2K12 / 2M4, -45 to +70 °C 3K22 / 3M11, +5 to +40 °C

Cooling method

Enforced air cooling (IP20, IP21, IP23) // enforced water cooling (IP54)

Safety of machinery - Safety-related parts of control systems

EN ISO 13849-1 EN ISO 13849-2

Safety of machinery

EN 60204-1 Exception: • Sec. 11.3 Protection type see Techn. Data • Sec. 13.2 Identification of conductors EN 61000-2-4 Class 3 EN 61000-6-2 EN 61000-6-4 respectively EN 55011 (Tab. 2) EN 61800-3 Cat.C2 (A1)

EMC Standards