General technical dataI-TS-3872 AC mains voltage / AC mains frequency
380 / 400 V ± 10 %, 3-phase, PE, 50 / 60 Hz ±5 %
Measurement accuracy Ripple voltage / current Voltage tolerance dynamic (0-100 % INom in 3 ms) Short circuit performance
Voltage: 16 Bit ADC // Current: 16 Bit ADC
≤ 0,1 % eff. fs Battery tester < 3 % fs Battery emulator < 1 % fs
Short circuit proof: Icw: 4,5 kA
Permissible environmental conditions: Storage as per EN 60721-3-1 Transport as per EN 60721-3-2 Operation as per EN 60721-3-3
1K21 / 1M11, +5 to +40 °C 2K12 / 2M4, -25 to +70 °C 3K22 / 3M11, +5 to +40 °C Enforced water cooling (IP54)
Cooling method
Safety of machinery - Safety-related parts of control systems
EN ISO 13849-1 EN ISO 13849-2
Safety of machinery
EN 60204-1 Exception: • Sec. 11.3 Protection type see Techn. Data • Sec. 13.2 Identification of conductor
EMC standards
EN 61000-2-4 Class 3 EN 61000-6-2 EN 61000-6-4
Type
Power in kW Current in A Dimensions (W x D x H in mm)
Voltage range 2x 5 – 750 V / 1x 10 - 1500 V I-TS-3872-1500-300-1000
300 600
1000 1000
2400 x 800 x 2200 4800 x 800 x 2200
I-TS-3872-1500-600-1000
27
evtestsystems.com
Made with FlippingBook Online newsletter