910132_PTS_GK Brochure

General technical dataI-TS-3872 AC mains voltage / AC mains frequency

380 / 400 V ± 10 %, 3-phase, PE, 50 / 60 Hz ±5 %

Measurement accuracy Ripple voltage / current Voltage tolerance dynamic (0-100 % INom in 3 ms) Short circuit performance

Voltage: 16 Bit ADC // Current: 16 Bit ADC

≤ 0,1 % eff. fs Battery tester < 3 % fs Battery emulator < 1 % fs

Short circuit proof: Icw: 4,5 kA

Permissible environmental conditions: Storage as per EN 60721-3-1 Transport as per EN 60721-3-2 Operation as per EN 60721-3-3

1K21 / 1M11, +5 to +40 °C 2K12 / 2M4, -25 to +70 °C 3K22 / 3M11, +5 to +40 °C Enforced water cooling (IP54)

Cooling method

Safety of machinery - Safety-related parts of control systems

EN ISO 13849-1 EN ISO 13849-2

Safety of machinery

EN 60204-1 Exception: • Sec. 11.3 Protection type see Techn. Data • Sec. 13.2 Identification of conductor

EMC standards

EN 61000-2-4 Class 3 EN 61000-6-2 EN 61000-6-4

Type

Power in kW Current in A Dimensions (W x D x H in mm)

Voltage range 2x 5 – 750 V / 1x 10 - 1500 V I-TS-3872-1500-300-1000

300 600

1000 1000

2400 x 800 x 2200 4800 x 800 x 2200

I-TS-3872-1500-600-1000

27

evtestsystems.com

Made with FlippingBook Online newsletter