900
Technical Specifications
900
AC Voltage
3 Phase, 380, 400, 440 and 480 VAC
AC Voltage Tolerance
+10%/-15%
AC Current Frequency
400, 380, 365 and 335 Amps respectively
60Hz ±2Hz (50Hz ±2Hz available)
Power Factor
≥ 0.95
Harmonic Distortion
< 3% THD; IEEE 519 Compliant
Power efficiency DC Voltage Max DC Current Max DC Power Max
95% 900V
±530A
±250kW 0-35 °C 0-60 °C
Operating environment - temperature Storage environment - temperature Operating environment - Humidity
0-90% Noncondensing
Weight
7,110 lbs (3,225 kg)
Dimensions
73” W x 76.5” H x 37” D (185cm W x 194cm H x 94cm D)
Performance Data Control Interface / Output data sampling
Local Control / CAN 33ms / RS-232 100ms
Control Software Options
LabView; C++ and visual basic, Remote operation system (ROS)
Rise time voltage - step (0-900v) Rise time voltage - step (0-300a)
10.45ms
0.6ms
Slew rate voltage Slew rate current Slew rate power
86.12V/ms 500A/ms 312.5kW/ms
Operating Range Configuration
Voltage (Vdc)
Current (Adc)
Power (kW)
+8 to +750
-530 to +530 -400 to +400 -300 to +300 -1000 to +1000 -800 to +800 -600 to +600
-250 to +250 -225 to +225 -200 to +200 -250 to +250 -225 to +225 -200 to +200
Independent
+751 to +825 +826 to +900
+8 to +750
Parallel
+751 to +825 +826 to +900
Accuracy & Resolution Measurement
Accuracy (±)
Resolution
Voltage
0.1% full scale 0.1% full scale
50mV 40mA
Current Independent (2 channels)
9
evtestsystems.com
*Ask us about our power curves
Made with FlippingBook Online newsletter