RECOVERY SCIENCES Catalogue 2026
Meet Our Team & Your Contact Recovery Sciences ENOVIS Nordic
Denmark
MICHELLE JOHNSEN Physiotherapist
PERNILLE SCHRØDER Physiotherapist DK Øst – Region Hovedstaden
DK Vest – Region Nordjylland og Region Midtjylland Vejleandapist M 24 40 05 69 michelle.johnsen@enovis.com
M 40 87 44 14 pernille.schroder@enovis.com
Finland
Norway
LINDA MÅRTENSSON Jr Commercial Manager
HAAKON FLINSTAD Physiotherapist
M +46 721 48 72 00 linda.martensson@enovis.com
M 94 13 13 04 haakon.flinstad@enovis.com
Sweden
ELISABETH ANDERSSON M.D. Rehabilitation Medicine Specialist V. Götaland, Dalarna, Västmanland Värmland, Södermanland Östergötland, Gotland, Västerbotten M 0702 09 71 19 elisabeth.andersson@enovis.com
HUGO ERIKSSON Physiotherapist
HELENE GARPEFORS Senior Product Specialist/Physiotherapist
Blekinge, Kalmar, Skåne Halland, Kronoberg, Jönköping Norrbotten M 0763 11 28 22 hugo.eriksson@enovis.com
Stockholm, Uppsala, Örebro Västernorrland, Gävleborg
M 0730 43 70 20 helene.garpefors@enovis.com
ENOVIS Benelux · Herentals
ENOVIS UK · Guildford
ENOVIS Germany · Freiburg
ENOVIS Canada · Toronto
ENOVIS Italy · Milan
ENOVIS Nordic · Malmö
ENOVIS Asia-Pacific HongKong
ENOVIS Switzerland · Ecublens
ENOVIS ETI · Asheboro, NC
ENOVIS France · Mouguerre
ENOVIS China Shanghai
ENOVIS · Vista, CA
ENOVIS Tunisia Sfax
ENOVIS · Indianapolis, IN
ENOVIS Spain · Barcellona
ENOVIS Australia Sydney, NSW
ENOVIS Mexico · Tijuana
ENOVIS Dallas . Texas
ENOVIS Surgical · Austin, TX
ENOVIS South Africa · Città del Capo
Enovis™ is specialized in the development, production, and distribution of high‐quality medical products for the musculoskeletal system, for vascular disorders, and for pain management.
Enovis™ products include orthopaedic braces, hot/cold therapy devices, bone growth and vascular treatment systems, rehabilitation equipment, physiotherapy and muscle electrostimulation devices, and a complete range of implantable orthopaedic prostheses for joint reconstruction of the hip, knee, and shoulder. Enovis™ medical devices are used by orthopaedic surgeons, nurses, pain management specialists, physiatrists, physiotherapy practitioners, osteopaths, chiropractors, and other healthcare professionals. They are marketed under the following brands: Aircast®, Chattanooga®, DonJoy®, Exos® & Procare®.
3
Orders and Terms – Summary
4
ENOVIS Medical Education
EXPERT INSTRUCTION, CUSTOMIZED PROGRAMS, PEER-TO-PEER LEARNING, INTERACTIVE EXPERIENCES, IN-PERSON, HANDS-ON Enovis™ Medical Education offers a suite of instructive programs focused on the safe and effective use of Enovis technologies and techniques. Interactive and customizable, this collection of best-in-class learning modules is tailored to physiotherapists, chiropractors, osteopaths and other health care professionals around the globe. Here you also get access to clinical and scientific research library, alongside webinars and additional resources designed to support learning and development. Covering a range of leading-edge topics in orthopedics and beyond, our programs are available for every experience level, empowering practitioners to advance their expertise and enhance patient outcomes across the continuum of care. The educational content draws from the knowledge of leading specialists and Enovis’ extensive range of products and services. Under expert guidance, participants may attend lecture-style presentations, examine case studies and scientific data and receive hands-on training. Partner with us to join the Enovis community and transform patient care. There are courses on Photobiomodulation Therapy, Radial Pressure Wave Therapy, Focused Shockwave Therapy, Therapeutic Ultrasound and Electrical Stimulation, amongst many others.
HOW DO I GET ACCESS TO ENOVIS MEDICAL EDUCATION? Use the QR code below
5
Orders and Terms – Summary How to place an order
Our Customer Policy You can expect fast and accurate delivery, along with friendly and knowledgeable customer service that will take your order and answer any questions. All our account managers are dedicated to supporting a specific region, so you can rely on expertise tailored to your area. If your designated Product Specialist happens to be unavailable, one of our other team members will gladly assist you with your needs.
You can be confident that your order will be shipped the same day, provided the requested item is in stock. We look forward to assisting you between 08:00 and 16:30
How to Order Orders by phone: DK 89 88 48 57 FI +46 40 39 40 00 NO 23 96 09 27 SE 040 39 40 00
Orders by e-mail: order.nordic@enovis.com
Orders via e-shop: www.enovisshop.com
ENOVISSHOP.COM
What We Will Ask For – when you order by phone Customer address: We require a complete delivery and billing address. Product: Please specify name, article number, description, and size.
Delivery Time Normal delivery time for stock items is 1–7 days, depending on your location, and approximately 2–4 weeks for special-order items. Orders placed before 12:00 (noon) on weekdays are shipped the same day. Your order will be shipped once it is complete and all items are available in our warehouse. Returns / Claims / Service Returns and exchanges apply to standard stock products that are returned in unopened original packaging within 14 days (private customers) or 30 days (business customers) from the delivery date. For special-order items, we do not offer returns or exchanges.
RETURNS / CLAIMS / SERVICE
Warranty All products come with a limited warranty from the date of purchase covering defects in materials and workmanship. The warranty period varies depending on the product.
6
INDEX
LIGHTFORCE ® – DEEP TISSUE LASER THERAPY™ ........ 10 LIGHTFORCE.. .. .. .. .. .. .. .. .. .. .. .. .............. 12 LIGHTFORCE ® XLi–40W.. .. .. .. .. .. .. .. .. ............. 14 LIGHTFORCE ® XPi–25W.. .. .. .. .. .. .. .. .. ............ 16 LIGHTFORCE ® FXi–15W.. .. .. .. .. .. .. .. .. ............. 17 FOCUSED SHOCKWAVE (F-SW) ................... 20 TREATMENT WITH FOCUSED SHOCKWAVES . . . . . . . . . . ...... 22 INTELECT FOCUS SHOCKWAVE . . . . . . . . . . . . . . . . ......... 24 F-SWHANDPIECE..................................24 INTELECT ® RPW – RADIAL PRESSURE WAVES ......... 26 INTELECTRPW2.................................. 28 INTELECTMOBILERPW2............................ 30 ACCESSORIES INTELECT ® RPW2........................32 ACCESSORIES INTELECT ® RPW2&MOBILERPW2 . . . . . . . ..... 32 RPW TRANSMITTERS . . . . . . . . . . . . . . . . . . . . ........... 33 INTELECTRPWLITE . . . . . . . . . . . . . . . . . . . . . ........... 34 PORTABLE ELECTROTHERAPY .................... 36 CEFARTENS.. .. .. .. .. .. .. .. .. .. .. .. ............. 38 CEFARBASIC.. .. .. .. .. .. .. .. .. .. .. .. ............. 39 CEFAR PERISTIM PRO . . . . . . . . . . . . . . . . . . . . ........... 40 CEFARREHABX2. . . . . . . . . . . . . . . . . . . . . . ............. 41 PROFESSIONAL PORTABLE ELECTROTHERAPY ......... 44 WIRELESS PRO 4 CHANNEL . . . . . . . . . . . . . . . . . . ......... 50 WIRELESS PRO 4CH STANDARD . . . . . . . . . . . . . . . . ........ 50 WIRELESSPRO4CHFULL............................ 50 PHYSIO.........................................52 THETA.. .. .. .. .. .. .. .. .. .. .. .. .. ............... 53 REHAB.. .. .. .. .. .. .. .. .. .. .. .. .. ............... 54 DYSPHAGIA THERAPY . . . . . . . . . . . . . . . . . . . . . . . . . . 58 VITALSTIMPLUS.................................. 59 ACCESSORIES AND ELECTRODES FOR CLINICAL AND PORTABLE ELECTROTHERAPY .......... 60 ACCESSORIES. . . . . . . . . . . . . . . . . . . . . . . ............. 61 ELECTRODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 CLINICAL ELECTROTHERAPY AND THERAPEUTIC ULTRASOUND ..................... 64 INTELECT ® MOBILE2STIM . . . . . . . . . . . . . . . . . . .......... 66 INTELECT ® MOBILE 2 ULTRASOUND . . . . . . . . . . . . . . ........ 66 INTELECT ® MOBILE2COMBO . . . . . . . . . . . . . . . . . ......... 66 INTELECT ® MOBILE2.. .. .. .. .. .. .. .. .. .. ............ 70 ACCESSORIES FOR INTELECT MOBILE 2 . . . . . . . . . . . . ....... 72 WAVEFORMS INTELECT MOBILE 2 . . . . . . . . . . . . . . . ........ 73
GALAXY TABLE RANGE ......................... 74 GALAXY 5 SECTION HIGH-LOW . . . . . . . . . . . . . . . . ......... 76 GALAXY 4 SECTION HIGH-LOW . . . . . . . . . . . . . . . . ......... 77 GALAXY 3 SECTION HIGH-LOW . . . . . . . . . . . . . . . . ......... 78 GALAXY 2 SECTION HIGH-LOW HEAD . . . . . . . . . . . . . . ....... 79 GALAXY 2 SECTION HIGH-LOW BACK . . . . . . . . . . . . . . ....... 80 MONTANE TABLE RANGE . . . . . . . . . . . . . . . . . . . . . . . . 82 MONTANETABLES . . . . . . . . . . . . . . . . . . . . . ............ 83 MONTANEANDES7SECTIONTABLE. . . . . . . . . . . . . . . . . . . . . 84 MONTANE ALPS 5 SECTION TABLE . . . . . . . . . . . . . . ........ 85 MONTANEATLAS3SECTIONTABLE . . . . . . . . . . . . . . . . . . . . . 86 MONTANE TATRAS /TATRAS GERLACH 2 SECTION TABLE . . . . . ... 87 MONTANE DOLOMITES2 SECTION EXAMINATION TABLE . . . . . . . . 88 MONTANE TAURUS BOBATH TABLES . . . . . . . . . . . . . . ....... 89 MONTANE COLOMBIA FIXED TABLES . . . . . . . . . . . . . . ....... 90 ACCESSORIES GALAXY & MONTANE . . . . . . . . . . . . . . ........ 91 KINESIOLOGY TAPE ........................... 92 CHATTTAPE..................................... 93 THERMOTHERAPY AND CRYOTHERAPY .............. 94 HYDROCOLLATOR® MOBILEHEATING UNIT . . . . . . . . . . . . . . . . . 95 HYDROCOLLATOR® FIXED HEATING UNITS . . . . . . . . . . . . . . . . . 96 HYDROCOLLATOR® ACCESSORIES . . . . . . . . . . . . . . . ........ 96 HOTPACS™ AND HYDROCOLLATOR® CARRIAGES . . . . . . . . . ..... 97 COLPAC®REFRIGERATIONUNIT. . . . . . . . . . . . . . . . . . . . . . . . 98 COLPAC® ACCESSORIES . . . . . . . . . . . . . . . . . . . . .......... 99 TRACTION TABLES ........................... 100 TRITON ® 6E.. .. .. .. .. .. .. .. .. .. .. .. .............. 104 TRITON ® 6M.....................................106 GALAXYTTET300 . . . . . . . . . . . . . . . . . . . . . ............ 108 TRITON® TRACTION UNIT . . . . . . . . . . . . . . . . . . ........... 109 ACCESSORIES. . . . . . . . . . . . . . . . . . . . . . . ............. 110 ESAOTE ................................... 112 ESAOTEMYLAB™A70............................... 114 ESAOTEMYLAB™A50............................... 116 ESAOTEMYLAB™C30............................... 118 ESAOTEMYLAB™C25...............................120 ESAOTEMYLAB™X1GO..............................122 ESAOTEMYLAB™X1. . . . . . . . . . . . . . . . . . . . . ............ 124 ESAOTEMYLAB™Q7................................126 ESAOTEPROBES . . . . . . . . . . . . . . . . . . . . . ............. 128
7
8
Chattanooga® is the world’s largest manufacturer of rehabilitation equipment for the treatment of musculoskeletal, neurological, and soft-tissue disorders. For over 70 years, Chattanooga® has been recognized as the standard of innovation, reliability, and excellence. Around the world, our products contribute to improving the effectiveness of treatments in hospitals, clinics, and home care. In the field of physiotherapy, for example, we lead the way with ongoing innovation, allowing us to provide effective solutions for medical professionals and their patients. Chattanooga® products are leaders in the field of rehabilitation and are sold in over 80 countries around the world. Chattanooga® is represented directly in major markets but also maintains strong, longstanding relationships with distributors in Canada, the United States, Latin America, the Middle East, and Asia. Chattanooga® distributors and customers can count on a team of highly qualified Enovis employees for training, delivery, and after- sales support. Chattanooga® is a brand of Enovis Inc. Enovis offers solutions for musculoskeletal health, vascular health, and pain management. Our products help prevent injuries and aid rehabilitation after surgery, trauma, or degenerative disorders, enabling patients to regain or maintain their natural movement.
www.ChattanoogaRehab.com
9
LIGHTFORCE ® – DEEP TISSUE LASER THERAPY™ LightForce® Therapy Lasers are known around the world for innovative technology and evidence-based treatment solutions. With thousands of customers across the globe, Chattanooga® estimates over 1 million+ treatments are performed using LightForce® Therapy Lasers per month. LightForce® Therapy Lasers are unique among laser devices in having a singular focus in rehabilitation and pain management.
LightForce® Therapy Lasers are manufactured in the United States and are rigorously tested for safety and consistency.
Over 250 professional and college sports teams trust LightForce® Therapy Lasers for their athletes. LightForce® lasers can be seen on the sidelines of the EFL Championship, Premier League, Olympics, NFL, NBA, MLB, NHL, MLS, PGA Tour, Cirque Du Soleil, UFC, and the X Games.
With over 7,000 articles published on Low Level Laser Therapy, photobiomodulation is well established in the scientific community for efficacy in treating musculoskeletal pain and increasing local blood circulation.
10
11
LIGHTFORCE
INFLUENCE ® TECHNOLOGY Influence® Technology takes into account the patient’s unique absorption characteristics and specific clinical condition to help provide the most effective treatment. Patient specifications such as condition, body type, and skin type are taken into account. The in-depth protocol settings provide recommended parameters on treatment heads
and power levels to aid in clinician confidence and reduced learning time.
EMPOWER IQ™ DELIVERY SYSTEM™
Model: 40W XLi, 25W XPi The LightForce® Empower IQ™ Delivery System is changing the game in laser therapy emission. Designed to be user friendly and responsive, Empower IQ™ is the new generation of delivery technology.
Smart Handpiece Built-in dosing feedback technology with embedded finger switch and indicator lights. In order to achieve effective treatments and improve dosing accuracy, the Smart Handpiece assesses the operator’s speed and gives real-time visual and sensory feedback. The Smart Handpiece is ergonomically styled for operator comfort.
Fiber Ultra-premium workmanship and next level durability. Extra-long for user convenience.
Quick Disconnect Heads Quick release and change-out treatment heads for better ease of use and versatile delivery options. The smart system senses appropriate applicators, treatment heads, associated power, and treatment hand speed.
Speed too fast
Speed too slow
Recommended Speed
12
EXCLUSIVE LIGHTFORCE® TREATMENT HEADS
EXCLUSIVE MASSAGE BALL TECHNOLOGY
Refractive Index The fused silica composition of the massage ball helps minimize light loss as it passes from the massage ball into the skin. Reflection On-contact application of delivery to tissue minimizes energy loss due to reflection. Soft Tissue Work The massage ball allows the clinician to do manual soft tissue work with the applicator while delivering energy.
The exclusive LightForce® patented massage ball allows the clinician to treat patients on-contact. Compression The on-contact massage ball compresses superficial tissues, displacing excess fluid and helping to enhance laser penetration to deep structures. This compression reduces theimpact of superficial absorbers. Collimation The massage ball acts to collimate the light beam, helping to reduce energy loss.
Small Cone Systems: 25W XPi, 15W FXi
When treating very narrow or precise areas, the Small Cone is ideal due to its smaller spot size.
Small Massage Ball Systems: 40W XLi, 25W XPi, 15W FXi Designed to be used with low to moderate power, the Small Massage Ball is ideal for treating trigger points, around the face, or the digits of the feet and hands. Flat Window Systems: 40W XLi, 25W XPi, 15W FXi The Flat Window is great for treating superficial tissues with small to moderate surface areas, especially in the presence of boney prominences. Large Massage Ball Systems: 40W XLi, 25W XPi, 15W FXi The most commonly used on-contact head, the Massage Ball reduces light scatter on the surface while allowing physical compression of tissue. Paired with higher power settings, it is the ideal tool to address problems in the back, hips, and larger muscle groups.. Large Cone Systems: 40W XLi, 25W XPi, 15W FXi The Large Cone is designed for off contact treatments that require higher power settings and is ideal for treating larger areas or when deeper tissues need to be addressed. The Large Cone is not recommended for treatment around the face or over smaller areas due to its larger spot size.
When laser therapy is applied directly to the skin in an on-contact manner, less energy is reflected, and tissue is compressed. This results in much more energy reaching the target tissue.
XL Cone System: 40W XLi Coupled with the patented Smart
POWER Ranging from 15 all the way to 40 watts of power, LightForce® Therapy Lasers provide the power needed to reach deep tissues. The increased power directly impacts the time needed to apply a therapeutic dose of light energy, allowing clinicians to decrease the time required to treat effectively. The higher power equips clinicians to treat deeper and faster while covering more tissue area in less time.
Handpiece, the XL Cone has the unique ability to keep high power treatment comfortable for most patients. With a spot size that is twice the size of our Large Cone, it allows clinicians to safely treat large areas and deeper conditions at over 25 Watts of power.
Rolling Pin System: 40W XLi
LightForce created the Rolling Pin to allow large areas to be treated with the 40W XLi with a one of a kind, oncontact head that makes treatments simple to administer.
TIME WITH PATIENS With an average treatment time of 4-7 minutes, clinicians can use laser therapy as part of an overall plan of care and maximize the time available to treat.
13
LIGHTFORCE ® XLi – 40W
ORDER INFORMATION
ARTICLE NO.
DESCRIPTION
XLI
SYS-000656-000-00 Light Force XLi (40W)
ACCESSORIES INCLUDED
XLi Handpiece Kit with 6 Treatment Applicators
KIT-000686-000-02
KIT-000685-000
Case with 4 Optical Applicators
PRD-000758-010-00-L Empower IQ System Handpiece 800 µm
Cylindrical Optical Applicator XL – Rolling Pin XL Applicator with Cylindrical Lens for Contact Treatment Cone XL – Conical Optical Applicator for Non-Contact Treatment Light Force XL Straps – Black Straps for XL Optical Applicators Large Sphere – Rolling Spherical Optical Applicator for Massage Large Cone – Conical Optical Applicator for Non-Contact Treatment Light Force Straps – Black Straps for Large Optical Applicators Small Sphere – Spherical Optical Applicator for Massage Flat Lens Applicator – Applicator with Flat Lens for Non-Contact Treatment Protective Cap – Protective Cover for Optical Applicators
PRD-000721-000
PRD-000644-000
PRD-000687-000
PRD-000229-010-00
PRD-000230-010-L
PRT000269
PRD-000231-000-L
Treat larger, deeper areas and provide faster pain relief with real time dosing feedback. Chattanooga’s most powerful laser, the 40W LightForce(r) XLi impacts deep tissue faster for pain relief in less time. The LightForce smart hand piece and onscreen recommendations increase dosing accuracy and help clinicians treat with confidence.”
PRD-000233-000
PLS-000367-000-L
PRT000240-L
Case for Optical Applicator Kit
Laser Type: Class IV, Solid State Laser Wavelength: 980/810 nm Laser Power: 1W – 40W
PRT000103-L
EU Power Cable, Type C
PRT000011-L
Protective Over-Glasses – DIN 5+
Operating Modes: CW or Pulsed Aiming Beam: 650 nm, < 4.5 mW Dimensions: 17” x 10.5” x 11” (43 x 28 x 26 cm)
Light Force Protective Glasses – Green, DIN 5+ Goggle-Style Glasses for Patient Protection
PRT000326
Weight: 19.6 lbs. (9 kg) Warranty: 24 months
PRT000473
Carrying Bag for Light Force 25W / 40W
PRD-000683-000-01
ACCESSORIES
Hard Case with Wheels for Transporting XPi (25W) and XLi (40W)
PRD-000215-010-L
PRD-000207-000-L
Trolley with Basket for Accessories
14
ROLLING PIN System: 40W XLi
15
LIGHTFORCE ® XPi – 25W
ORDER INFORMATION
ARTICLE NO.
DESCRIPTION
XPI
SYS-000837-000-00 Light Force XPi (25W)
ACCESSORIES INCLUDED
XPi Handpiece with 5 Treatment Applicators
KIT-000686-000-01
KIT-000497-000-02
Case with 4 Optical Applicators
Empower IQ System Handpiece – 800 µm Large Sphere – Rolling Spherical Optical Applicator for Massage Large Cone – Conical Optical Applicator for Non-Contact Treatment Light Force Straps – Black Straps for Large Applicators Small Sphere – Spherical Optical Applicator for Massage Small Cone – Conical Optical Applicator for Non-Contact Treatment Flat Lens Applicator – Applicator with Flat Lens for Non-Contact Treatment Protective Cap – Protective Cover for Optical Applicators
PRD-000758-010-00-L
PRD-000229-010-00
PRD-000230-010-L
PRT000269
PRD-000231-000-L
PRD-000232-000-L
PRD-000233-000
Smarter than your average laser. The 25W LightForce(r) XPi gives real time visual and haptic feedback, allowing clinicians to provide consistent, accurate treatments. The XPi’s built-in intelligence tells users which treatment heads are acceptable or not recommended for different power levels, which helps to provide for safer treatments and less guesswork from clinicians.”
PLS-000367-000-L
PRT000240-L
Case for Optical Applicator Kit
PRT000103-L
EU Power Cable – Type C
Laser Type: Class IV, Solid State Laser Wavelength: 980/810 nm Laser Power: 1W – 25W
PRT000011-L
Protective Over-Glasses – DIN 5+
Light Force Protective Glasses – Green, DIN 5+ Goggle-Style Glasses for Patient Protection
PRT000326
Operating Modes: CW or Pulsed Aiming Beam: 650 nm, < 4.5 mW Dimensions: 17” x 10.5” x 11” (43 x 28 x 26 cm)
PRT000473
Weight: 19.6 lbs. (9 kg) Warranty: 24 months
Carrying Bag for Light Force 25W / 40W
PRD-000683-000-01
ACCESSORIES
Hard Case with Wheels for Transporting XPi (25W) and XLi (40W)
PRD-000215-010-L
Trolley with Basket for Accessories
PRD-000207-000-L
Hard Case with Wheels for Transporting XPi (25W) and XLi (40W)
PRD-000215-010-L
PRD-000207-000-L
Trolley with Accessory Basket
16
LIGHTFORCE ® FXi – 15W
ORDER INFORMATION
ARTICLE NO.
DESCRIPTION
FXI
SYS-000829-000-00 Light Force FXi (15W)
ACCESSORIES INCLUDED
FX1 Handpiece (15W) – Empower System 600 µm Case with 4 Optical Applicators Includes: Case, Large Sphere, Small Sphere, Large Cone, Small Cone Large Sphere – Spherical Optical Applicator for Massage Large Cone – Conical Optical Applicator for Non-Contact Treatment Light Force Straps – Black Straps for Large Applicators Small Sphere – Spherical Optical Applicator for Massage Small Cone – Conical Optical Applicator for Non-Contact Treatment Flat Lens Applicator – Applicator with Flat Lens for Non-Contact Treatment Protective Cap – Protective Cover for Optical Applicators
PRD-000424-010-01
KIT-000497-000-00-L
PRD-000229-000-L
PRD-000230-000-L
PRT000269
PRD-000231-000-L
PRD-000232-000-L
PRD-000233-000
Treat quickly and consistently on the go. The 15W LightForce(r) FXi is ideal for those practices or athletic training rooms needing to treat in multiple locations in or out of the office. Easily transportable with an integral battery, the lightweight FXi quickly impacts pain while weighing in at only 7 lbs.”
PLS-000367-000-L
PRT000240-L
Case for Optical Applicator Kit
PRT000103-L
EU Power Cable – Type C
Laser Type: Class IV, Solid State Wavelengths: 980/810 nm Laser Power: 0.5W – 15W
Power Supply for 15W–150W, 12V, AC–DC
ELX-000767-000-L
Operating Modes: CW or Pulsed Aiming Beam: 650 nm, < 4.5 mW Dimensions: 15” x 11” x 8” (38 x 28 x 20 cm)
PRT000297-L
Battery
PRT000011-L
Protective Over-Glasses – DIN 5+
Light Force Protective Glasses – Green, DIN 5+ Goggle-Style Glasses for Patient Protection
Weight: 7 lbs (3.2 kg) Warranty: 24 months
PRT000326
PRT000473
PRD-000807-000-01 Carrying bag for Light Force 15W
ACCESSORIES
Hard Case with Wheels for Transporting XFi (15W)
PRD-000204-010-L
PRD-000207-000-L
Trolley with Accessory Basket
17
MUSCLE & JOINT PAIN RELIEF
INDICATIONS Deep Tissue Laser Therapy™ is used to treat painful muscles and joints associated with acute and chronic soft tissue injuries. It is also indicated for helping relieve pain and stiffness associated with osteoarthritis via its ability to increase localized blood flow. These factors make therapeutic laser a sensible modality choice for post-activity recovery.
CLINICALLY STUDIED TO HELP IN THE TREATMENT OF: Neck Pain (1) Low Back Pain (2,3) Sciatica (4,5) TMJ (6,7) Elbow and Joint Pain (8) Arthritis (9)
LARGE MASSAGE BALL Systems: 40W XLi, 25W XPi, 15W FXi
18
CLINICAL STUDIES – KLASS 4 LASER
1. ElsodanyAM, AlayatMSM, Ali MME, KhapraniHM. Long-Term Effect of Pulsed Nd:YAGLaser in the Treatment of Patients with Rotator Cuff Tendinopathy: A Randomized Controlled Trial. PhotomedLaser Surg. 2018 Sep;36(9):506-513. 2. Kim GJ, Choi J, Lee S, Jeon C, Lee K. The effects of high intensity laser therapy on pain and function in patients with knee osteoarthritis. J Phys Ther Sci. 2016 Nov;28(11):3197-3199 3. İnce S, Eyvaz N, Dündar Ü, Toktaş H, Yeşil H, Eroğlu S, Adar S. Clinical Efficiency of High-Intensity Laser Therapy in Patients With Cervical Radiculopathy: A 12-Week Follow-up, Randomized, Placebo-Controlled Trial. Am J Phys Med Rehabil. 2024 Jan 1;103(1):3-12. 4. Tumilty S, Mani R, Baxter GD. Photobiomodulation and eccentric exercise for Achilles tendinopathy: a randomized controlled trial. Lasers Med Sci. 2016 Jan;31(1):127 35. 5. Chung H, Dai T, Sharma SK, Huang YY, Carroll JD, Hamblin MR. (2012), The nuts and bolts of low-level laser (light) therapy. Ann Biomed Eng Feb;40(2):516-33 6. Clijsen R, Brunner A, Barbero M, Clarys P, Taeymans J. Effects of low-level laser therapy on pain in patients with musculoskeletal disorders: a systematic review and metaanalysis. Eur J Phys Rehabil Med. 2017 Aug;53(4):603-610. 7. Chow RT, Johnson MI, Lopes-Martins RA, Bjordal JM. Efficacy of low-level laser therapy in the management of neck pain: a systematic review and meta-analysis of randomised placebo or active-treatment controlled trials. Lancet. 2009 Dec 5;374(9705):1897-908. doi: 10.1016/S0140 6736(09)61522-1. Epub 2009 Nov 13. Erratum in: Lancet. 2010 Mar 13;375(9718):894. PMID: 19913903. 8. Alayat MS, Atya AM, Ali MM, Shosha TM. Long-term effect of high-intensity laser therapy in the treatment of patients with chronic low back pain: a randomized blinded placebo-controlled trial. Lasers Med Sci. 2014 May;29(3):1065-73. doi: 10.1007/s10103-013-1472-5. Epub 2013 Nov 2. 9. Yousefi-Nooraie R, Schonstein E, Heidari K, Rashidian A, Pennick V, Akbari-Kamrani M, Irani S, Shakiba B, Mortaz Hejri SA, Mortaz Hejri SO, Jonaidi A. Low level laser therapy for nonspecific low-back pain. Cochrane Database Syst Rev. 2008 Apr 16;(2):CD005107. doi: 10.1002/14651858 CD005107.pub4. PMID: 18425909. 10. Holanda VM, Chavantes MC, Silva DF, de Holanda CV, de Oliveira JO Jr, Wu X, Anders JJ. Photobiomodulation of the dorsal root ganglion for the treatment of low back pain: A pilot study. Lasers Surg Med. 2016 Sep;48(7):653-9. doi: 10.1002/lsm.22522. Epub 2016 May 2. PMID: 27135465. 11. Jovicić M, Konstantinović L, Lazović M, Jovicić V. Clinical and functional evaluation of patients with acute low back pain and radiculopathy treated with different energy doses of low level laser therapy. Vojnosanit Pregl. 2012 Aug;69(8):656-62. PMID: 22924260. 12. Abbasgholizadeh ZS, Evren B, Ozkan Y. Evaluation of the efficacy of different treatment modalities for painful temporomandibular disorders. Int J Oral Maxillofac Surg. 2020 May;49(5):628-635. doi: 10.1016/j.ijom.2019.08.010. Epub 2019 Sep 21. PMID: 31547949. 13. Khairnar S, Bhate K, S N SK, Kshirsagar K, Jagtap B, Kakodkar P. Comparative evaluation of low-level laser therapy and ultrasound heat therapy in reducing temporomandibular joint disorder pain. J Dent Anesth Pain Med. 2019 Oct;19(5):289-294. doi: 10.17245/jdapm.2019.19.5.289. Epub 2019 Oct 30. PMID: 31723669; PMCID: PMC6834715. 14. Roberts DB, Kruse RJ, Stoll SF. The effectiveness of therapeutic class IV (10 W) laser treatment for epicondylitis. Lasers Surg Med. 2013 Jul;45(5):311-7. doi: 10.1002/lsm.22140. Epub 2013 Jun 3. PMID: 23733499. 15. Dima R, Tieppo Francio V, Towery C, Davani S. Review of Literature on Low-level Laser Therapy Benefits for Nonpharmacological Pain Control in Chronic Pain and Osteoarthritis. Altern Ther Health Med. 2018 Sep;24(5):8-10. PMID: 28987080.
19
FOCUSED SHOCKWAVE (F-SW)
20
21
TREATMENT WITH FOCUSED SHOCKWAVES
FOCUSED SHOCKWAVES (F-SW) Focused shockwaves are used to treat deep target areas. Focused extracorporeal shockwave therapy allows for precise diagnosis and treatment of both active and latent trigger points. These waves can penetrate approximately 12 cm with pinpoint accuracy. BIOMECHANICAL ASPECTS Unlike radial shockwaves, the power of focused shockwaves makes it possible to reduce calcifications or stones and to stimulate tissue regeneration, in addition to offering the general benefits typically associated with shockwave therapy:
1. Treating calcifications 2. Activating the healing cascade
3. Improving blood flow 4. Regenerating tissue
THREE SPACER SIZES FOR TREATMENT VERSATILITY The spacers offer various treatment options. The shorter the applicator, the more powerful the shockwave and the deeper the penetration. The longer the applicator, the more precise the focal zone.
STAND-OFFS AND PENETRATION DEPTHS OF THE F-SW HANDPIECE
SKIN
FOCAL ZONE MAX 30 MM
WITHOUT STAND-OFF
50 mm
Focal zone: 35 – 65 mm Therapeutic effectiveness: 0 – 125 mm
STAND-OFF I (SHORT)
30 mm
Focal zone: 15 – 45 mm Therapeutic effectiveness: 0 – 105 mm
STAND-OFF II (LONG)
15 mm
Focal zone: 0 – 30 mm
Therapeutic effectiveness: 0 – 90 mm
22
TARGETED PAIN RELIEF Shockwaves are used to treat a wide range of pathologies in areas such as bone healing, tendinopathies, muscular trigger points/myofascial pain, dermatology, wound healing, spasticity and impotence (erectile dysfunction). It can be easier to find deeper, painful, diffuse trigger points with shockwave therapy than with palpation.
EPICONDYLITIS
CALCIFIC TENDINITIS
PATELLAR TENDINITIS
TRAPEZIUS MUSCLE
TIBIAL STRESS SYNDROME
HEEL SPUR
ACHILLODYNIA
PLANTAR FASCIITIS
23
INTELECT FOCUS SHOCKWAVE
ORDER INFORMATION
ARTICLE NO.
DESCRIPTION
INTELECT ® FOCUS SHOCKWAVE
21090
Kit Intelect ® F-SW
ACCESSORIES INCLUDED
19000
Handpiece for F-SW
4600
Water bag
4700
Silicone oil
Conductive gel, 1 bottle of 250 ml
13-00061
User manual
0.0032.012 Power cable
19100
Stand-off I (30 mm)
19200
Stand-off II (15 mm)
Shockwaves are used to treat a wide range of pathologies in areas such as bone healing, tendinopathies, muscular trigger points/myofascial pain, dermatology, wound healing, spasticity and impotence (erectile dysfunction). Focus shockwave has high energy (around one hundred times more powerful than a Radial Pressure Wave) making it suitable for a range of conditions in urology, orthopaedic indications, cardiology and neurology. Focus Shockwave’s power (shockwaves can penetrate approximately 12 cm with pinpoint focus) allows it to disintegrate calcifications, stones, and growths as well as providing the standard benefits of shockwave therapy; activation of the healing cascade, enhanced blood flow, and tissue regeneration.
Transparent locking ring for Stand-off I and II
19300
ACCESSORIES
4650
F-SW Cart
19000
F-SW Handpiece
19100
Stand-off I (30 mm)
19200
Stand-off II (15 mm)
Transparent locking ring for Stand-off I and II
19300
TREATMENT GUIDELINES • 12.5 cm penetration with pinpoint focus • Enhanced energy: 0.01 – 0.55mJ/mm2 • Broad frequency range: 1 – 8 Hz • 3 standoff variations for tailored treatment • LCD touch screen • 2 year warranty, or up to 1 million pulses on the handpiece
19150
Urology Stand-off
0.0032.012 Power cable
13-26497
F-SW Coil Maintenance Kit
28701
Revision kit
F-SW HANDPIECE
24
25
INTELECT ® RPW – RADIAL PRESSURE WAVES
26
27
INTELECT RPW 2
The Intelect ® RPW 2 allows for the treatment of indications with radial, pneumatically-generated, low-energy acoustic waves, or ‘pressure pulses’. The applied pressure pulse propagates radially within the tissue, generating a therapeutic effect. The V-ACTOR ® HF optional hand piece allows mechanical vibration, for vibration massage.
FALCON ® HANDPIECE allowing lower Bar
LARGE GRAPHIC COLOR TOUCH SCREEN High resolution 7” capacitive touch screen for greater customer experience.
SUGGESTED PROTOCOLS LIBRARY Available at a finger click; treatment pictures, anatomical
pressures for an increased range of indications and applicators.
and pathological library, treatments guidelines.
COMFORT MODE Unique automatic energy ramp up designed to provide better patient comfort.
V-ACTOR ® HF* Vibration frequency up to 50Hz for Vibration therapy and muscle relaxation. (accessorio opzionale)
LARGE CHOICE OF TRANSMITTERS* 17 different transmitters available for tendinopathies, trigger points, spine and fascia treatments.
EASY FIT FOR EVERY TREATMENT ROOM Slim design 41 x 42 x 110 cm (L x W x H), not a lot of space needed for this new RPW generation.
ERGONOMIC DESIGN What you is need close in hand; handpiece, transmitter tray, gel bottle, cables holders, soft pouch.
EXTENDED PRESSURE RANGE The Falcon handpiece provides a greater pressure range from 0.3 to 5 bar, making it more comfortable for the patient and allowing Fascia and Spine treatments. NOTE: PERI-V-ACTOR ® and SPINE-V-ACTOR ® can only be used under 3 Bar pressure.
28
INTELECT RPW 2
ORDER INFORMATION
ARTICLE NO. DESCRIPTION
INTELECT ® RPW 2
2174KIT
Intelect ® RPW 2
ACCESSORIES INCLUDED
Falcon® Handpiece (includes: 2 projectiles, 2 guide tubes, 1 cleaning brush, 1 open-end wrench, 1 Allen key)
18080
13-28660 Quick Start Guide
22652
Tray for Transmitters
22651
Gel Bottle Holder
Conductive Gel – 1 Bottle (250 ml)
28178
Red Ro40 Transmitter
29724
D20-S Transmitter – 20 mm
82-0274
Hanging Bag for Intelect® RPW 2
15-1140
USB Key
14820
Power Cable
ACCESSORIES
Falcon® Handpiece (includes: 2 projectiles, 2 guide tubes, 1 cleaning brush, 1 open-end wrench, 1 Allen key)
18080
28739
Guide Tube Cleaning Brush
Service/Revision Kit — includes: 2 projectiles, 2 short guide tubes, 2 sets of O‑rings, 1 O‑ring guide (for Falcon® and Sparrow™)
29104
29801
A6 Black Transmitter
29802
T10 Black Transmitter
29729
C15 Black Transmitter
29728
DI15 Black Transmitter
29726
F15 Black Transmitter
29724
D20-S Black Transmitter
29725
D35-S Black Transmitter
28736
D20-T Gold Transmitter
TREATMENT GUIDELINES • Localize the painful areas you plan to treat
28178
Ro40 Red Transmitter
29539
ATLAS RPW Transmitter
• Select most appropriate transmitters based on treatment goal and targeted tissue • Apply ultra sound water based gel on the skin overlying the treatment area • Always start with lower level of intensity • Perform a post-treatment test to assess improved function and decrease in pain • Warranty 3 years
V-Actor® HF Handpiece – for Intelect® RPW 2 and Mobile RPW 2 only (includes V25 and V40) 36–50 Hz – Black V-Actor® Handpiece – for Intelect® RPW2, RPW, Mobile RPW2, and Mobile RPW (includes V25 and V40) 21–35 Hz – Blue
19365
28730
SPECIFICATION
V-Actor ® V10 Transmitter
29742
DIMENSIONS
410 x 1100 x 425 mm
28740
V-Actor ® V25 Transmitter
WEIGHT
30 kg
28741
V-Actor ® V40 Transmitter
Set of 9 Transmitters with Case – includes: A6, T10, C15, DI15, F15, D20‑S, D35‑S, D20‑T, Ro40 PERI-ACTOR© Set of 4 Fascial Transmitters SPINE-ACTOR© Set of 3 Spinal Transmitters
This device complies with the applicable standards EN/IEC 60601-1, CAN/CSA-C22.2 No.601.1, UL Std. No 60601-1. Class IIa device 93/42 60601-1
31800
28945
28946
82-0274
Intelect® RPW 2 Bag
29
INTELECT MOBILE RPW 2
ORDER INFORMATION
ARTICLE NO. DESCRIPTION
INTELECT ® MOBILE RPW 2 2910
Intelect ® Mobile RPW 2
ACCESSORIES INCLUDED
Handpiece D-Actor® for Intelect® Mobile RPW 2 (includes: 2 projectiles, 2 long guide tubes, 1 Allen key (hex key), 1 adjustable wrench, 1 seal kit, 1 cleaning brush, 1 handpiece case)
32000
28178
Red Ro40 transmitter
29724
D20-S transmitter, 20 mm Conductive gel, 1 bottle of 250 ml
13-00060 CD User Manual 21184 Power cable ACCESSORIES
Barrel cover for Mobile RPW 2 handpiece Handle cover for Mobile RPW 2 handpiece
22375
22376
28178
RO40 transmitter red
29801
A6 Black Transmitter
29729
C15 Black Transmitter
29726
F15 Black Transmitter
29728
DI15 Black Transmitter
Offers a broader range of shock frequency and greater power (up to 5 Bar of pressure), making it a more flexible tool for helping patients recover.
29724
D20-S Black Transmitter
28736
D20-T Gold Transmitter
The versatility of the Mobile 2 RPW makes it suitable for a range of environments and applications: orthopaedics, physiotherapy, aesthetic therapy, chiropractors, rheumatology, sports clubs, veterinary, physical medicine, acupuncture and podiatrists. TREATMENT GUIDELINES • All the features of the original Mobile RPW but with improved functionality • Single and Continuous shocks: Frequency D-ACTOR: 1 – 21 Hz, Frequency V-ACTOR: 1 – 31 Hz • 1-5 Bars of pressure, infinitely variable with precise adjustments of 0.1 increments • 2 year warranty, 1 year on accessories
29725
D35-S Black Transmitter
29802
T10 Black Transmitter
29742
V-Actor ® V10 Transmitter
28740
V-Actor ® V25 Transmitter
28741
V-Actor ® V40 Transmitter
28745
Carrying bag for Mobile RPW 2
Set of 9 transmitters with case, includes: A6, T10, C15, DI15, F15, D20-S, D35-S, D20-T, Ro40 V-Actor® Handpiece 36–50 Hz HF, for Intelect® RPW 2 and Mobile RPW 2 only (includes V25 and V40) V-Actor® Handpiece for Intelect® RPW2, RPW, Mobile RPW 2, and Mobile RPW (includes V25 and V40) 21–35 Hz Overhaul Kit for D-Actor® Handpiece (includes: 2 projectiles, 2 long guide tubes, 2 O-ring sets, 1 O-ring guide) D-Actor® Handpiece for Intelect® Mobile RPW 2 (includes: 2 projectiles, 2 long guide tubes, 1 Allen key, 1 adjustable wrench, 1 seal kit, 1 cleaning brush, 1 handpiece case)
31800
19365
28730
28701
32000
MOBILE RPW CARRY BAG
ARTICLE NO.
DESCRIPTION
21184
Power cable
28745
Mobile RPW Carry Bag
4248-12
Conductive gel (24 bottles of 250 ml)
13-00060 CD User Manual
30
FREQUENTLY ASKED QUESTIONS
HOW MANY SESSIONS ARE REQUIRED? Most patients experience significant improvement within 3 to 5 sessions, depending on the condition’s severity and chronicity. (Chattanooga focused and radial shockwave systems allow clinicians to tailor treatment intensity and frequency for faster recovery.) Schmitz et al (2015) WHAT IS A TYPICAL PROTOCOL FOR TREATING TENDINOPATHIES? A standard protocol includes one session per week for 3–6 weeks, depending on tissue response. Treatment involves targeting the affected tendon using Chattanooga customizable energy levels and transmitters/applicators, often combined with eccentric loading or functional rehab for best results. IS SHOCKWAVE THERAPY ONLY FOR CHRONIC CONDITIONS? While shockwave is especially effective for chronic injuries, Chattanooga devices can also be used in subacute stages to modulate pain, reduce inflammation, and accelerate healing—always based on clinical judgment. DOES FREQUENCY MAKE ANY DIFFERENCE IN OUTCOME? Research shows mixed results regarding frequency role in shockwave therapy. While it may affect depth of penetration, treatment comfort, and tissue response, it is not the sole driver of outcome. Chattanooga systems offer a wide frequency range (1–15 Hz), allowing clinicians to tailor treatments to each patient’s needs. Frequency should be considered alongside energy level, treatment protocol, and diagnosis for best results. CAN SHOCKWAVE THERAPY BE USED WITH OTHER MODALITIES / TREATMENTS? Absolutely. Combining Chattanooga Shockwave with Light Force Laser Therapy can produce synergistic effects— shockwave for mechanical stimulation and tissue remodelling, and Light force laser therapy for cellular regeneration and inflammation control. This integrative approach enhances outcome in both acute and chronic musculoskeletal conditions.
CLINICAL STUDIES – SHOCKWAVE
1. Ibrahim, Noha Hosni, Refaat Mostafa El Tanawy, Amal Fathy Soliman Mostafa and Mayada Fawzy Mahmoud. “Extracorporeal shock wave therapy (ESWT) versus local corticosteroid injection in treatment of lateral epicondylitis (tennis elbow) in athletes: clinical and ultrasonographic evaluation.” Egyptian Rheumatology and Rehabilitation 48 (2021) 2. Stania M, Juras G, Marszałek W, Król P. Analysis of pain intensity and postural control for assessing the efficacy of shock wave therapy and sonotherapy in Achilles tendinopathy – A randomized controlled trial. Clin Biomech (Bristol). 2023 Jan;101:105830. 3. Rajfur K, Rajfur J, Matusz T, Walewicz K, Dymarek R, Ptaszkowski K, Taradaj J. Efficacy of Focused Extracorporeal Shock Wave Therapy in Chronic Low Back Pain: A Prospective Randomized 3-Month Follow-Up Study. Med Sci Monit. 2022 Jun 11;28:e936614. 4. Hammam RF, Kamel RM, Draz AH, Azzam AA, Abu El Kasem ST. Comparison of the effects between low- versus medium-energy radial extracorporeal shock wave therapy on knee osteoarthritis: A randomised controlled trial. J Taibah Univ Med Sci. 2020 May 15;15(3):190-196. 5. Dunn SL, Olmedo ML.(2016), Mechanotransduction: Relevance to Physical Therapist Practice-Understanding Our Ability to Affect Genetic Expression Through Mechanical Forces. Phys Ther. May;96(5):712-21
31
ACCESSORIES INTELECT ® RPW 2
ORDER INFORMATION
ARTICLE NO.
DESCRIPTION
C
A
B
A GEL HOLDER
22651
Gel stand
4248-12
Conductive gel (24 bottles of 250 ml)
B CARRYING BAG FOR INTELECT® RPW 2
82-0274
Hanging bag
C TRAY
D
E
F
22652
Transmitter tray
D USB FLASH DRIVE
15-1140
USB stick
E GUIDE TUBE CLEANING BRUSH
28739
Guide tube cleaning brush
F REVISION KIT
29104
Revision Kit
TECHNICAL SPECIFICATIONS Mains power supply
ACCESSORIES INTELECT ® RPW 2 & MOBILE RPW 2
230V AC 50-60Hz 350VA
Weight
30 kg
Dimensions L x W x H Compressed air pressure
410 x 1100 x 425 mm
REVISION KIT
0.3-5.0 bar
PART NUMBER
DESCRIPTION
Power increment setting Impulse amplitude
Revision Kit (2x Guide Tube, Projectile, Sealing Set)
0.1 bar
28701
Approx. 2 mm at 3 bar, at minimum setting, without coupling
Impulse width Approx. 6–12 ms
Falcon® Handpiece 1–21 Hz for RPW; V-Actor® Handpiece 1–50 Hz vibration
Impulse frequency
Mode
Single pulse or continuous
D-ACTOR KIT
7” color capacitive touchscreen, 800 x 480 pixels The equipment complies with all standards: EN/IEC 60601-1, CAN/CSA-C22.2 No.601.1, UL Std. No 60601-1
User interface
PART NUMBER
DESCRIPTION
Safety compliance
D-ACTOR Kit (no transmitters)
28699
Medical Device Classification
CLASS IIA, 93/42, 60601-1
WARRANTY 3 years: Intelect® RPW 2
2 years or 3 million pulses: Handpiece 1 year: Transmitters and accessories 1 year: V-Actor Handpiece
V-ACTOR KIT
PART NUMBER
DESCRIPTION
Note: For further information, please refer to the user manual.
28730
V-ACTOR Kit
32
RPW TRANSMITTERS
ORDER INFORMATION
A COMPATIBLE WITH INTELECT® RPW 2, MOBILE RPW 2 & RPW LITE
ARTICLE NO.
DESCRIPTION
TRANSMITTERS
A COMPATIBLE WITH: INTELECT® RPW 2, MOBILE RPW 2
C15 Black Transmitter
29729
• Ceramic Energy 15 mm transmitter for any type of tendonopathies • Penetration depth 0-35 mm • Intensity level: High
• Standard Oscillator, 20 mm transmitter or muscle and connective tissue • Myofasciak treatments • Penetration depth 0-50 mm • Intensity level: Medium
• 15 mm beam transmitter with c oncave coupling surface, best for pain zones near the skin surface • Penetration depth 0-35 mm
• Golden Depth 15 mm Deep Impact®transmitter for deep target areas, chronic disorders, local trigger points • Penetration depth 0-50 mm • Intensity level: High
Ro40 Red Transmitter
28178
DI15 Black Transmitter
29728
• Intensity level: Medium • RPW Lite version is black
D20-S Black Transmitter
29724
D20-T Gold Transmitter
28736
B COMPATIBLE WITH: INTELECT® RPW 2 & MOBILE RPW 2
A6 Black Transmitter
29801
T10 Black Transmitter
29802
• Golden Oscillator 20 mm transmitter for professional athletes • Myofasciak treatments • High energy application • Penetration depth 0-50 mm • Intensity level: Very High
T F15 Black Transmitter
29726
D35-S Black Transmitter
29725
V-Actor ® V10 Transmitter
29742
V-Actor ® V25 Transmitter
28740
B COMPATIBLE WITH INTELECT® RPW 2 & MOBILE RPW 2
V-Actor ® V40 Transmitter
28741
C COMPATIBLE WITH: INTELECT® RPW 2
ATLAS RPW Transmitter
29539
PERI-ACTOR© Set of 4 Fascial Transmitters SPINE-ACTOR© Set of 3 Spinal Transmitters
28945
• Acupuncture like transmitter 6 mm for local trigger points • Penetration depth 0-20 mm • Intensity level: Low
• Finger transmitter 10 mm for deep target tendonopathies • Penetration depth 0-40 mm • Intensity level: High
• White soft transmitter 15 mm for superficial
• Large oscillator 35 mm for large muscles and connective tissue • Myofasciak treatments • Penetration depth 0-60 mm • Intensity level: Medium
28946
pain regions, muscles of mastication, cervical spine • Penetration depth 0-30 mm • Intensity level: Very Low
• Ø 10 mm • Treatment of superficial trigger points
• Ø 25 mm • Lymphatic drainage • Muscle smoothing • Massage • Increase in local blood circulation • Connective tissue activation
• Ø 40 mm • For large Muscle areas
• Lymphatic drainage • Muscle smoothing • Massage • Increase in local blood circulation • Connective tissue activation
C COMPATIBLE WITH INTELECT® RPW 2
• Double Tip shape to allows treatments of the paravertebral region. • 3 sizes span from 20 to 35 mm
• Soft flexible tipped transmitter 15 mm for highly sensitive regions and triggerpoints in the cervical spine • Penetration depth 0-15 mm • Intensity level: Low
PERI-ACTOR ® KNUCKLE PERI-ACTOR SPHERE • Unique shape especially designed to dissolve clots in the Fascia structures PERI-ACTOR SCOOP PERI-ACTOR ® SCRAPER
33
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90 Page 91 Page 92 Page 93 Page 94 Page 95 Page 96 Page 97 Page 98 Page 99 Page 100 Page 101 Page 102 Page 103 Page 104 Page 105 Page 106 Page 107 Page 108 Page 109 Page 110 Page 111 Page 112 Page 113 Page 114 Page 115 Page 116 Page 117 Page 118 Page 119 Page 120 Page 121 Page 122 Page 123 Page 124 Page 125 Page 126 Page 127 Page 128 Page 129 Page 130 Page 131 Page 132Made with FlippingBook - PDF hosting