L1

L2

14 PSI (.96 BAR) 7.5 LPM

650/1000

TDC-5583i

158

100

9.0

72:1

PRIMARY

TDC-5583i

SECONDARY

C

+ -

SECONDARY PICKUP COIL

TRANSFORMER CASE MUST BE GROUNDED. TRANSFORMER WILL BE SHIPPED WITH A JUMPER CONNECTING SECONDARY CENTER TAP TO CASE. USER MUST PROVIDE APPROPRIATE GROUNDING OF SECONDARY CIRCUIT. FOR APPLICATIONS ABOVE A 20% DUTY CYCLE, CONTACT ROMAN MANUFACTURING FOR ASSISTANCE.

NOTE* The secondary terminals of this device

0.260 [6.6] X 45° Chamfer

are intended as an electrical connection only. Applications must be designed to minimize any forces applied to the secondary terminals, this can be accomplished by transferring forces to a structural member.

14.989 [380.7]

WATER CONNECTION 2X USE 10MM I.D. O-RING 30°C MAX. INLET TEMP.

8.465 [215.0]

1.627 [41.3]

1.750 [44.5]

0.875 [22.2]

0.525 [13.3]

2.500 [63.5]

5 PIN MALE RECEPTACLE TURCK FSD4.5-0.5

M10x1.5 HeliCoil - 6H 15MM LG 16X

5.000 [127.0]

CONNECTION FOR ROMAN DEP

M10x1.5 HeliCoil - 6H Z 0.810 [15] 4X

1

2

C

5

3

4

C B A

UPDATED DRAWING NOTES 4 PIN RECEPTACLE WAS BRAD HARRISON 0.525[13.3] WAS 0.650[16.5]

PRS BCC 3/23/2016 BCC MS 3/9/2016 RB BCC 1/4/2016

REV

DETAILER: • 650 Volt, 1,000 Hz • 100 KVA @ 50% duty cycle • Secondary no load DC voltage of 9.0 volts • Integrated Flow Switch • Secondary pick-up coil • Fully encapsulated to ensure long life • Water-cooled, 7.5 L.P.M. (2 G.P.M.) minimum@ 30°C • Weight: 20.6 kilograms (45.5 lbs) APPROX N/A WEIGHT: DESIGNER: DRAWINGNUMBER: DESCRIPTION DATE © 2015CopyrightRoManManufacturing. THISDRAWING AND ALL THE INFORMATION AND TECHNOLOGY IN IT ARE EXCLUSIVE, CONFIDENTIAL AND PROPRIETARY TO RoManMANUFACTURING, INC. THISDRAWING ISOWNED BYRoManMANUFACTURING, INC., AND UNLESS SPECIFICALLY AUTHORIZED INWRITING,NO COPIES SHALL BEMADEOF THISDRAWING, AND SHALL BEUSEDONLY FOR THE LIMITED PURPOSE FORWHICH IT ISDISCLOSED ANDONLY TO THE BENEFITOF RoManMANUFACTURING INC., AND IT AND ANYCOPIES, AUTHORIZEDORNOT, SHALL BE IMMEDIATELY RETURNEDUPON ANY REQUEST THEREFORE. 5583-1i NONE 7/14/2015 TRANSFORMER ASSEMBLY TDC-5583i jbetit bconner SCALE: DATE:

C

Power Supply Rating Diagram Single Phase, Center Tap Rectifier. Size “2” Rectifier

DIMENSIONS: IN[MM]

Weld time in cycles (50/60 Hz) l Ti e in Cycles (50/60Hz) Rectifier Rating Curve

Transformer Rating Curve

For more information

Notes • These curves are based on rated water flow of 7.5 L.P.M. (2 G.P.M.). • Maximum water in temperature of 30°C. • For applications about a 20% duty cycle, contact RoMan Manufacturing ® for assistance. Rectifier Rating: % Duty Cycle is based on shortest time from beginning of one weld to the beginning of next weld. On time/(On + Off time). Transformer Rating: % Duty Cycle is total “On” time in one minute.

Grand Rapids, Michigan 616.530.8641 romanmfg.com

4-2017