Step 5.
Installation of Top Angle for Roof. (Item T-7)
(A) The inside height of the oven should be determined by the height of
the wall panels. All T-7 angles come in 10 ft. lengths. If the oven length is
longer than 10 ft., you need to add whatever length is needed. You must
keep angle the same from the floor to the top of the angle all the way down
complete length of oven installing Tek Screws as you go (see Dwg. 5-A).
(B) When you install top angle across back of oven, you must notch and
weld end to top angle of side walls.