Section C

Door Header and Side Wall Face Channel

Step 6.

Installation of Side Wall Face Channel and Door Header.

(A) You will have two (for single entry oven) and four (for double entry

oven) C4 x 5.4 channels wit h ¼” holes 12” apart (see customer prints for item

number).

(B) Install these by forcing them over the male end of the side wall panel.

Make sure top and bottom of channels are flat against panel (see drawing).

Put 4 ft. level on face of channel to insure face of the oven is plumb. If both

sides are not plumb, the doors will not seal properly. Install all Tek Screws

(Dwg 6-B).

(C) Get proper measurement from customer drawings and mark location

face channel for door header. Place door header on mark.

The ¼” end

plates on the door header should be flush with outside of the face channel.

Tack door header in place (see Dwg 6-C) ( do not weld solid until door

opening is squared, after step 6-F).