2026 Veloris Catalogue

Victron Inverter RS 48/6000 Smart Inverter RS 48/6000 Smart Light weight, efficient and quiet Thanks to high frequency technology and a new design this powerful inverter weighs only 11 kg. In addition to this it has an excellent efficiency, low standby power, and a very quiet operation. Display and Bluetooth The display reads battery and inverter parameters. The same parameters can be accessed with a smartphone or other Bluetooth enabled device. In addition, Bluetooth can be used to set up the system and to change settings with VictronConnect. VE.Can and VE.Direct port VE.Can connection to a GX device for system monitoring, data logging, and remote firmware updates. VE.Direct connection to a GlobalLink 520 for remote data monitoring. I/O Connections Programmable Relay, temperature sensor and voltage sensor connections. The remote input can also be configured to accept the Victron smallBMS.

Inverter RS Smart

48/6000

INVERTER

DC Input voltage range

38 – 62 V (4)

Output voltage: 230 VAC ± 2 % Frequency: 50 Hz ± 0.1 % (1) Maximum continuous inverter current: 25 Aac Increases linearly from 4800 W at 46 VDC to 5300 W at 52 VDC

Output

Continuous output power at 25 °C Continuous output power at 40 °C Continuous output power at 65 °C

4500 W 3000 W

Peak power

9 kW for 3 seconds 7 kW for 4 minutes

Short-circuit output current

50 A

Maximum efficiency

96.5 % at 1 kW load 94 % at 5 kW load

Zero load power

20 W

CHARGER

Programmable Charger voltage range (VDC)

36 – 60 V

Charge voltage 'absorption' (VDC)

Default setting: 57,6 V (adjustable) Default setting: 55,2 V (adjustable)

Charge voltage 'float' (VDC) Maximum charge current Battery temperature sensor

88 A @ 57.6V

Included

Battery voltage sense

Yes

GENERAL

Parallel and 3-phase operation

12 parallel units supported, 3 phase supports 4 units per phase

Programmable relay (3)

Yes

Protection (2)

a - g

Data Communications

VE.Direct port, VE.Can port & Bluetooth

Bluetooth frequency & power

2402 – 2480 MHz, 4dBm

General purpose analogue/digital in port

Yes, 2x

Remote on-off

Yes

Operating temperature range

-40 to +65 °C (fan assisted cooling)

Maximum altitude

2000 m max 95 %

Humidity (non-condensing)

ENCLOSURE

Material & Colour Protection category Battery-connection 230 VAC-connection

steel, blue RAL 5012

IP21

M8 bolts

Screw terminals 10 mm² (6 AWG)

Weight

11 kg

Dimensions (H x W x D)

425 x 440 x 125 mm

STANDARDS

Safety

EN-IEC 60335-1, EN-IEC 62109-1, EN-IEC 62109-2

EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3

Emission, Immunity

1) Can be adjusted to 60 Hz. 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) Solar earth leakage. 3) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4A up to 35 VDC and 1 A up to 70 VDC. 4) Minimum start-up voltage is 41 V. Inverter shutdown can be set as low as 32 VDC, but may shut down on low AC output voltage (due to load). Over-voltage disconnect is 65.5 V.

Product Catalogue.

143