Fluke Calibration 9142, 9143 and 9144 Field Metrology Wells
Field temperature calibration with precision and speed Whether you need to calibrate 4-20 mA transmitters or a simple thermostatic switch, a Fluke Calibration Field Metrology Well is the right tool for the job With three models covering the range of –25°C to 660°C, this family of Metrology Wells calibrates a wide range of sensor types The optional process version (models 914X-X-P) provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter
Recommended Accessories
HART DRYWELL CABLE 754/Dry-Well/ Microbath Interface Cable Fluke 9308/9316
9142-CASE Carrying Case (914X)
• Lightweight, portable, and fast • 9142 –25°C to 150°C ±02°C • 9143 33°C to 350°C ±02°C
• 9144 50°C to 660°C ±035°C to 420°C ±05°C at 660°C • Cool to –25°C in 15 minutes and heat to 660°C in 15 minutes • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current • True reference thermometry with accuracy to ±001°C • Automate calibration with the Fluke 754 or Fluke 1586A or use on-board automation with process version • One year warranty
Fluke 9144
9308 Carrying Case
9316 Rugged Carrying Case
Complete Solution Fluke 754 with 914X Series Field Metrology Well By combining the automating and documenting capabilities of the Fluke 754 Documenting Process Calibrator (see page 108) with Fluke Calibration’s intelligent and stable family of field drywells and micro-baths, you have the capability to test the entire loop This combination of equipment allows you to easily verify the characteristics of the temperature sensor and measurement electronics Using this information, the entire loop can be adjusted to optimise system measurement performance
Well inserts X in the model number to be replaced with A, B, C, D, E, or F as appropriate for the desired insert
Models
9142-X Field Metrology Well, -25°C to 150°C 9142-INSA 9142-INSB 9142-INSC 9142-X-P Field Metrology Well, -25°C to 150°C, process version 9143-X Field Metrology Well, 33°C to 350°C 9143-INSA Field Metrology Well, 33°C to 350°C, process version 9144-X Field Metrology Well, 50°C to 660°C 9144-INSA 9143-INSB 9143-INSC 9143-X-P
Insert A, 9142, misc holes Insert B, 9142, comp holes Insert C, 9142, 6 × 0 25 in holes Insert A, 9143, misc holes Insert B, 9143, comp holes Insert C, 9143, 6 × 0 25 in holes Insert A, 9144, misc holes Insert B, 9144, comp holes Insert C, 9144, 6 × 0 25 in holes
9144-INSB 9144-INSC
Field Metrology Well, 50°C to 660°C, process version
9144-X-P
Fluke Calibration 9103 and 9140 Field Dry-Well Calibrators
Fluke Calibration's 9103 and 9140 Field Dry-Well Calibrators beat every other comparable dry-well in the industry in performance, size, weight, convenience, ease of calibration, software, and price In addition, the heating and cooling rate of each of these dry-wells is adjustable from the front panel, thermal switches can be checked for actuation testing, and multiple-hole inserts are available for a variety of probe sizes • Lightweight and very portable • Two models ranging from -25°C to 350°C
• Accuracy to ±025°C • Stability to ±002°C • RS-232 and Interface-it software included
• Easy to recalibrate • One year warranty
Fluke 9140
Specify X, X = A, B, C, or D included insert
Models
9103-X Field Dry-Well Calibrator, –25°C to 140°C 9140-X Field Dry-Well Calibrator, 35°C to 350°C
Insert A: 1/16” (16 mm), 1/8” (32 mm), 3/16” (48 mm), 1/4” (635 mm), 3/8” (95 mm) & 1/2” (127 mm) Insert B: 2 at 3/16” (48 mm), 2 at 1/4” (635 mm) & 2 at 3/8” (95 mm) Insert C: 6 at 1/4” (635 mm) Insert D: 2 at 3 mm, 2 at 4 mm & 2 at 6 mm
C ontact your local distributor for price and availability. au.flukecal.com/where-to-buy
fluke co/calibration
Process Calibration Tools
115