Fluke 2022 IG Test Tools Catalogue

Fluke 1507 and 1503 Insulation Resistance Testers

These lightweight, affordable insulation testers are perfect for troubleshooting, commissioning and preventive maintenance applications • Automatic calculation of polarisation index and dialectric absorption ratio (1507 only) • Multiple test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V (1507 only) • Remote test probe for rapid testing • Insulation test range 001 MΩ to 10 GΩ (1507), 01 MΩ to 2000 MΩ (1503) • Compare (Pass/Fail) function for repetitive tests (1507 only) • Live circuit detection prevents insulation test if voltage > 30 V is detected • Auto-discharge of capacitive voltage • AC/DC voltage: 01 V to 600 V • Lo ohms/Earth-bond continuity (200 mA) for checking connections and motor windings • Resistance: 001 Ω to 2000 Ω • One year warranty

Recommended Accessories

TPAK Magnetic Meter Hanger See page 155

TL225 Stray Voltage Adapter Test Lead Kit See page 149

TL27 Heavy Duty Test Lead Set See page 146

TLK289 Industrial Master Test Lead Set See page 149

Fluke 1507

Fluke 1503

C116 Soft Carrying Case See page 157

C101 Hard Case See page 158

Fluke 1507/1503 Applications

Features

1503

1507

User selectable test voltages for many applications Additional test voltages 50 V, 100 V, 250 V

l

l

l

Special remote control probe for easy and safe measurements Auto-discharge of capacitive voltage for added user protection Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection Save both time and money with Automatic calculation of Polarisation Index and Dielectric Absorption Ratio

l

l

l

l

l

l

l

Auto Power off to save batteries Large display with backlight Continuity function (200 mA)

l

l

Insulation test at a distribution panel

l

l

l

l

Compare function (pass/fail) for fast repetitive tests

l

Insulation

1503

1507

Insulation test range

01 MΩ to 2000 MΩ

001 MΩ to 10 GΩ

Test voltages

500 V, 1000 V + 20%, - 0% 1 mA nominal

50 V, 100 V, 250 V, 500 V, 1000 V

Test voltage accuracy Insulation test current

+ 20%, - 0% 1 mA nominal

Wiring test in a small distribution box – all in one spot

AC/DC Voltage measurement Resistance measurement range

600 V (0 1 V resolution)

600 V (0 1 V resolution)

001 Ω to 20 kΩ

001 Ω to 20 kΩ

Auto discharge

Discharge time < 05 second for C = 1 µF or less

Discharge time < 05 second for C = 1 µF or less

Maximum capacitive load Open circuit test voltage

Up to 1 µF

Up to 1 µF

> 4 V , < 8 V

> 4 V , < 8 V

Short circuit current

> 200 mA

> 200 mA

General Battery life

Meter: 1000 hours Insulation Test: >1000 tests 203 mm × 100 mm × 50 mm

Size (HxWxD)

Included Accessories TL224 Test Leads, TP74 Test Probes, Clips PN 1958654 (red) and PN 1958646 (black), Holster, Remote Probe and User Manual Ordering Information FLUKE-1507 Insulation Tester FLUKE-1503 Insulation Tester

Weight

055 kg

C ontact your local distributor for price and availability. fluke.co/wtb

78

Insulation Testers

Made with FlippingBook Learn more on our blog