HOUSING
Concept Conversions Ltd Thermal , Acoustic & Fire Solution Manufacturers
Data Sheet 1002
TIMBER CAVITY BARRIER
DESCRIPTION :
CCL Timber Cavity Barrier consists of a length of flexible mineral wool slab fully enclosed in polythene with flanges on each side for initial fixing purposes
PURPOSE : CCL Timber Cavity Barriers are designed to prevent fire penetration and minimise sound transmission through the wall cavities of timber framed buildings .
BENEFITS :
Meet full Building Regulations Fire , thermal and acoustic solution
Simple to install Water repellent Maintenance free
Specification
Fixing : CCL Timber Cavity Barriers do not rely on their polythene flanges to hold them in place . They are supplied 10mm to 15mm thicker than the cavity in which they are to be installed . This ensures a tight fit as they are held in place by compression between the inner leaf and outer brickwork . During vertical installation , both flanges are fixed to the inner timber sheathing using non - corrosive clout nails or staples at 150mm centres . During horizontal installation the upper flange only is stapled or nailed to the inner timber sheathing . The breather membrane should be cut to overlap the upper flange of the Timber Cavity Barrier . Special attention must be paid to the joints to ensure that these are very closely butted . Cavity barriers may fail at the joints if a gap is left . The Cavity Barrier should fully fill the whole cavity .
Dimensions
CCL Timber Cavity Barriers are supplied in 1200mm lengths and are factory cut to suit cavity widths from 50mm to 150mm . Cavities wider than 150mm can be accommodated , although CCL Firestop Slab may be a more suitable application .
Standards & Performance :
The mineral wool core of a CCL Timber Cavity Barrier achieves a fire classification of Euroclass A1 as defined in BS EN 13501 - 1 . The correct use of a CCL Timber Cavity Barrier will exceed the requirement for a 30 minute cavity fire barrier as defined in Approved Document B of the Building Regulations 2010 ( 2019 edition ) Table 3 of Appendix B . The product has been independently tested adopting procedures and criteria from BS476 : part 20 :( 1987 ) and achieved a 1 hour fire resistance . Approved Document B of the Building Regulations 2010 ( 2019 edition ), Section 8 details the requirement and purpose for which a cavity barrier should be installed . CCL Timber Cavity Barriers comply with the robust details accepted to provide a solution which satisfies the Approved Document E 2003 ( 2015 edition ) of the Building Regulations relating to the transmission of sound .
sales @ concept - conversions . co . uk
01933 - 673100
www . concept - conversions . co . uk
Unit 13 , Trinity Centre , Park Farm Industrial Estate , Wellingborough , Northants , NN8 6ZB .