COMMERCIAL
Concept Conversions Ltd Thermal , Acoustic & Fire Solution Manufacturers
Data Sheet 1008
CAVITY FIRESTOP SLAB
DESCRIPTION :
CCL Cavity Firestop Slab consists of rigid slabs of mineral wool faced on both sides with reinforced aluminium foil . The foil facing is printed with lines along the length to aid the fabrication of cut strips on site . The slab can be supplied factory cut to suit specific cavity widths , and where necessary , have a layer of DPC bonded to one edge . PURPOSE : CCL Cavity Firestop Slab is designed to prevent the passage of fire in all cavity walls as well as between a curtain wall system and a concrete floor slab .
BENEFITS :
Available in slabs or cut to size Suits cavities 15mm - 300mm wide Simple to cut and install 1 and 2 hour fire resistance Water repellent
Horizontal Firestop between floor slab
Specification
Dimensions :
Curtain Wall & Cladding Systems :
Firestop 60mm - 75mm x 600mm x 1200mm Firestop 120mm - 100mm x 600mm x 1200mm
Standards & Performance :
The mineral wool core of a CCL Cavity Firestop slab achieves a fire classification of Euroclass A1 as defined in BS EN 13501 - 1 . The product has been independently tested adopting procedures and criteria from BS476 : part 20 : ( 1987 ). CCL Cavity Firestop 60mm and 120mm slabs comply with the provisions of Approved Document B 2010 ( 2019 edition ). CCL Cavity Firestop
Horizontal Firestop within masonry cavity wall
The CCL Cavity Firestop system is suitable for use with wall cladding systems . The performance of the firestop will depend upon the integrity and stability of the cladding system for the duration of the fire rating where required . Where there is a possibility of significant distortion during a fire , the cladding system must be attached to the structural floor , close to the firestop , with steel brackets . Due to the variety of cladding available , the system manufacturer should be contacted to confirm the suitability of its use with the firebarrier for the resistance period required .
- Firestop60 provides 1 hour fire resistance - Firestop120 provides 2 hours fire resistance .
Fixing :
sales @ concept - conversions . co . uk
Clips are required when the barrier is installed horizontally . They may be omitted during vertical installation if the barrier is supported at the base . The fixing clips should be bent into a Z shape and penetrate the firestop by over half of its overall width at a rate of 2 per length ( approx . 300mm from end to end ) The barrier should be securely fitted into the cavity ensuring it is compressed by approximately 5mm and the ends form a tight butt joint . The fixing clip should then be mechanically fixed to the floor slab or inner block work . Finally seal the joints with Class O aluminium foil tape .
01933 - 673100
www . concept - conversions . co . uk
Unit 13 , Trinity Centre , Park Farm Industrial Estate , Wellingborough , Northants , NN8 6ZB .