Fluke 787B and 789 ProcessMeter ™
Double the troubleshooting power so you can do more, while carrying a lot less The Fluke 787B and 789 ProcessMeter™ double troubleshooting capabilities by combining the power of a safety rated digital multimeter and mA loop calibrator into a single, compact test tool. Whether you only need to source and simulate mA, or need a 24 V loop power supply, Fluke has a ProcessMeter™ test tool designed • 20 mA DC current source/measure/simulate • Simultaneous mA and% of scale readout • DMM designed to meet 1000 volt IEC 61010 CAT III and 600 V CAT IV standards • Fluke Connect ® compatibility for wireless data logging (with IR3000FC module) • Precision 1000 V, 440 mA true-RMS digital multimeter • Frequency measurement to 20 kHz • Min/Max/Average/Hold/Relative modes • Diode test and continuity beeper • Manual step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp • Externally accessible battery for easy battery changes • Three year warranty Fluke 789 additional features • 24 V loop power supply • HART mode setting with loop power (adds 250 ohm resistor) specifically to meet your needs. Fluke 787B and 789 key features
Recommended Accessories
IR3000 FC Fluke Connect ® ir3000 Connector See page 178
TPAK ToolPak Meter Hanging Kit See page 177
80T-150UA Universal Temperature Probe See page 169
TL220 SureGrip™ Industrial
Test Lead Set See page 167
Fluke 789
Fluke 787B
80PK-8 Pipe Clamp Temperature Probe See page 169
Recommended Kits
Bundle & Save
Best Accuracy (% of reading + LSD)
Measurement Function
Range and Resolution
V DC
400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V
0.1% + 1
V AC (True-RMS)
0.7% + 2
mA DC
30.000 mA
.05% + 2 0.2% + 2
Fluke Connect ® 789 ProcessMeter™ and Temperature Kit For more details see page 195
A DC A AC
1.000 A (0.440 A continuous) 1.000 A (0.440 A continuous)
1% + 2
Resistance
400.0 O, 4.000 kO, 40.00 kO, 400.0 kO, 4.0 MO, 40 MO 199.99 Hz, 1999.9 Hz, 19.999 kHz 2.000 V (shows diode voltage drop) Beeps for resistance < approx. 100 ohms
0.2% + 1
Frequency (0.5 Hz to 20 kHz)
.005% + 1
Diode Rest Continuity
2% + 1
Included Accessories TL71 Test Lead Set, AC72 Alligator Clips, Four AA Alkaline Batteries, User Manual and Quick Reference Guide. Ordering Information FLUKE-787B ProcessMeter ™ FLUKE-789 ProcessMeter ™ FLUKE-789/ T3000FC Fluke Connect 789 ProcessMeter ™ & Temperature Kit
Output Function DC Current Output (Internal Battery Operation)
Range and Resolution
Drive Capability 24 V compliance or, 1,200 ohms, @ 20 mA
Accuracy
0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA
.05%
DC Current Simulate (Ext. 15 V to 48 V loop supply) 24 V Loop Supply* Current Adjustment Modes
1000 ohms, @ 20 mA
.05%
Minimum 24 V
250 ohms @ 20 mA > 24 V
Manual: Coarse, Fine, 25% and 100% step Automatic: Slow Ramp, Fast Ramp, 25% step
FLUKE- IR3000 FC
Fluke Connect ® Infrared Connector FlukeView ® Forms Software (incl. Interface Cable)
*24 V Loop Supply available on 789 ProcessMeter TM only.
FVF-SC2
C ontact your local distributor for price and availability. fluke.co/wtb
fluke.co/calibration
Process Calibration Tools
121
Made with FlippingBook Learn more on our blog