Fluke 2024 IG Test Tools Catalogue

AC CURRENT CLAMPS

AC Current Clamp Specifications

i200

i200s

i400

i400s 0.5 A to 400 A

i800

i1000s 0.2 A to 1000 A

i3000s i2000 Flex i3000s Flex i6000s

AC current range

60 A to 6000 A

1 A to 200 A 1 A to 200 A 1 A to 400 A

1 A to 800 A

1 A to 3000 A 2 A to 2000 A 3 A to 3000 A

0.2 to 10 A: 3% + 0.1 A 10 A to 100 A: 2% + 0.5 A 100 A to 1000 A: 1% + 1 A 48 Hz to 65 Hz

1 to 30 A: 2% + 0.1 A 1 to 300 A: 2% + 0.5 A 1 to 3000 A: 2% + 2 A 48 Hz to 65 Hz

.5 A to 40 A, 2% + .015 A, 5 A to 400 A, 2% + .04 A, 45 Hz to 400 Hz

0.1 A to 10 A ±3% + .01 A, 10 A to 200 A ±2%, 200 A to 800 A ±1%

±1% of range 45 Hz to 65 Hz Ranges: 20 A, 200 A, 2000 A

±1% of range, 45 Hz to 65 Hz Ranges: 30 A, 300 A, 3000 A

< 3% + 0.5 A 48 Hz to 65 Hz

< 1% + 0.5 A 48 Hz to 65 Hz

2% + 0.06 A 45 Hz to 400 Hz

±1% of range 45 Hz to 65 Hz

Accuracy

Bandwidth (-3 dB) Maximum conductor diameter Maximum conductor size

40 Hz to 40 kHz

40 Hz to 40 kHz

5 kHz to 20 kHz

5 Hz to 10 kHz

30 Hz to 10 kHz (typical)

5 Hz to 100 kHz

10 Hz to 100 kHz

10 Hz to 20 kHz

10 Hz to 50 kHz

10 Hz to 50 kHz, (- 3 dB) 193 mm or 289 mm

177 mm or 265 mm 610 mm or 915 mm circumfer- ence 100 mV/A 10 mV/A 1 mV/A

20 mm 20 mm 32 mm 32 mm 54 mm 54 mm 64 × 100 mm 177 mm

2× 240 mm² or 1× 500 mm²

2× 240 mm² or 1× 500 mm²

610 mm circumfer- ence 100 mV/A 10 mV/A 1 mV/A

610 mm or 915 mm

150 mm 2

150 mm 2

400 mm 2

400 mm 2

64 mm

1 mV/A 10 mV/A 100 mV/A

10 mV/A 1 mV/A 0.1 mV/A

50 mV/A 5 mV/A 0.5 mV/A

Output levels

10 mV/A 100 mV/A

10 mV/A 1 mV/A

1 mA/A

1 mA/A

1 mA/A

2 m with double shrouded banana plugs

2 m to BNC, 4 mm plug adapter supplied

1.5 m shrouded banana plugs

1.5 m shrouded banana plugs

1.6 m shrouded banana plugs

Output cable

2 m to BNC termination

2.5 m to BNC termination

1.6 m to BNC termination

2.1 m to BNC termination

2.1 m to BNC termination

Warranty

One-year

One-year

One-year

One-year

One-year

One-year

One-year

One-year

One-year

One-year

Safety rating

CAT III 1000 V CAT IV 600 V

CAT III 1000 V CAT IV 600 V

CAT III 600 V CAT III 600 V

CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V

AC Current Clamp Selection Guide

i200

i200s

i400

i400s 0.6 A to 400 A* 0.6 A to 400 A* 0.6 A to 400 A*

i800

i1000s 0.6 A to 1000 A* 0.6 A to 1000 A* 0.6 A to 1000 A* 0.1 A to 1000 A* 0.2 A to 1000 A* 0.1 A to 1000 A* 0.3 A to 1000 A* 0.3 A to 1000 A* 0.1 A to 1000 A* 0.2 A to 1000 A* 0.2 A to 1000 A* 0.1 A to 1000 A 0.3 A to 1000 A 0.25 A to 1000 A 0.1 A to 1000 A 0.1 A to 1000 A* 0.2 A to 1000 A* 0.2 A to 1000 A*

i3000s

i2000 Flex1 i3000s Flex

110/APAC 114/116 115/117

1 A to 200 A

1 A to 3000 A 2 A to 2000 A 3 A to 3000 A

60 A to 200 A 1 A to 200 A 60 A to 400 A

60 A to 800 A

1 A to 3000 A 2 A to 2000 A 3 A to 3000 A

233

60 A to 200 A 1 A to 200 A 60 A to 400 A

60 A to 800 A

1 A to 3000 A 2 A to 2000 A 3 A to 3000 A

1 A to 3000 A

2 A to 2000 A

3 A to 3000 A

27II

2 A to 200 A 1 A to 200 A 2 A to 400 A 1 A to 400 A* 2 A to 800 A

28II

1.8 A to 200 A 1 A to 200 A 1.8 A to 400 A 1.8 A to 400 A 1.8 A to 800 A

2 A to 3000 A 2 A to 2000 A 3 A to 3000 A

77 IV

1 A to 200 A

1 A to 400 A*

1 A to 3000 A 2 A to 2000 A 3 A to 3000 A

175/177/179 3 A to 200 A 1 A to 200 A 3 A to 400 A 1 A to 400 A* 3 A to 800 A

3 A to 3000 A 2 A to 2000 A 3 A to 3000 A

3 A to 3000 A 1 A to 3000 A 2 A to 3000 A 1 A to 3000 A 1 A to 3000 A 1.2 A to 3000 A 2.5 A to 3000 A 1 A to 3000 A 1 A to 3000 A 1 A to 3000 A 2 A to 3000 A

2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A 2 A to 2000 A* i430Flex- TF-II 2 A to 2000 A* 2 A to 2000 A

3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A 3 A to 3000 A* i430Flex- TF-II 3 A to 3000 A* 3 A to 3000 A

1577/1587FC 3 A to 200 A 1 A to 200 A 3 A to 400 A 3 A to 400 A* 3 A to 400 A

83V/88V

2 A to 200 A 1 A to 200 A 2 A to 400 A 1 A to 400 A* 2 A to 800 A

87V

2 A to 200 A 1 A to 200 A 2 A to 400 A 2 A to 400 A* 2 A to 800 A

0.5 A to 400 A*

287/289

1 A to 200 A 1 A to 200 A 1 A to 400 A

1 A to 800 A

43B

1 A to 200 A

0.35 A to 400 A

1.2 A to 400 A 2.5 A to 400 A

434/435-II

1 A to 200 A

120/B

1 A to 200 A

190/-II

1 A to 200 A

1 A to 400 A

0.5 A to 400 A*

8808A

1 A to 200 A 1 A to 200 A 1 A to 400 A

1 A to 800 A

8845A/8846A 1 A to 200 A 1 A to 200 A 1 A to 400 A 1 A to 400 A* 1 A to 800 A

787B/789

50 A to 200 A 1 A to 200 A 50 A to 400 A 2 A to 400 A* 50 A to 440 A

170

Fluke Accessories

Made with FlippingBook Learn more on our blog