Fluke 2024 IG Test Tools Catalogue

Fluke 902 FC True-RMS HVAC Clamp Meter

Improve productivity in the field The Fluke 902 FC delivers the features necessary to diagnose and repair HVAC systems. Additionally, with Fluke Connect ® you can trend measurements, create and send reports right from the field, safely stay away from live equipment. Applications for HVAC • 200 µA DC current measurements to measure flame rod • Extended resistance range to measure thermistors up to 60 kΩ • Capture flue gas temperature • Measure start and run motor capacitors

Recommended Accessories

Fluke 902 FC

AC220 SureGrip™

TL224 SureGrip™ Insulated Test Leads See page 167

Alligator Clips See page 167

• Measure performance of variable frequency drives • Temperature measurement from -10°C to 400°C • 1000 µF capacitance measurement • CAT III 600 V, CAT IV 300 V safety rating • Three year warranty

80PK-8 Pipe Clamp Temperature Probe See page 169

80AK-A Thermocouple Adapter See page 169

Functions Range

Resolution Accuracy

A AC (via Jaw)

±(2.0% + 5 digits) (45-65 Hz) ±(2.5% + 5 digits) (65-400 Hz) ±(1.5% + 5 digits) (45-400 Hz)

60/600 A 0.01/0.1 A

Fluke 902 FC

V AC V DC

600 V 600 V

0.1 V 0.1 V

±(1.5% + 5 digits)

TPAK Magnetic Hanging Strap See page 177

C781 Meter Case See page 176

600/6,000 /60,000 Ω

True RMS

Ohms

0.1/1/10 ±(1% + 5 digits)

µA

200 µA

0.1 µA

±(1% + 4 digits)

Contact Temperature

10 to 400 o C 0.1 C/F

±(1% + 8 digits)

Capacitance 100.0/1000 µF 0.1/1 µF

±(1% + 4 digits)

Continuity Beeper Beep Volume 75 dBA nom. 15 cm from case front On Threshold <=30 Ω

Fluke 368 FC/369 FC AC True-RMS Leakage Current Clamp Meters

Measure leakage current to track small problems, avoid large problems The Fluke 360 Series of True-RMS Leakage Current Clamp Meters help users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, without taking equipment offline. • True-RMS measurements for accuracy when measuring complex, non-sinusoidal waveforms • Jaw size: 40 mm (368 FC) and 61 mm (369 FC) • Current resolution 1 µA/0.01 mA and 0.01 A/0.1 A • Frequency range 40 Hz to 1 kHz • Selectable filter 40 Hz to 70 Hz or wideband 40 Hz to 1 kHz • Highest resolution of 1 μA, measure up to 60 A • Forward-facing LED worklight for use in dark wiring cabinets • Backlit display; auto backlight off and auto power off for extended battery life. • Wireless data connectivity via Fluke Connect ® • CAT III 600 V safety rating • Three year warranty

Included Accessories Fluke 902 FC: TL75 Test leads, 80BK Integrated DMM Temperature Probe, Two AA Alkaline Batteries, Soft Carrying Case, Statement of Calibration Practices and User Manual. Fluke 368 FC/369 FC: Soft Case, Two AA Batteries, Safety Manual. Ordering Information FLUKE 902 FC HVAC Clamp Meter FLUKE 368 FC AC Leakage Current Clamp Meter FLUKE 369 FC AC Leakage Current Clamp Meter

Fluke 368 FC

Fluke 369 FC

True RMS

Specifications Measurement Function Alternating current AC Ampere Range

3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A mA A: manual selection 3 mA, 30 mA, 300 mA: automatic selection 3 A, 30 A, 60 A: automatic selection

Range Selection

Frequency

40 Hz to 1 kHz

Crest Factor

Three

fluke.co/clamps

Clamp Meters

35