Fluke 2024 IG Test Tools Catalogue

Fluke 50 Series II Thermometers Lab accuracy in a field thermometer

Recommended Accessories

The Fluke 50 Series II Contact Thermometers offer fast response and laboratory accuracy in a rugged handheld test tool. • Laboratory accuracy: ±(0.05% + 0.3°C) • Large backlit dual display • Min/Max/Avg • Electronic offset function maximises overall accuracy • Supports a wide range of thermocouple types • Temperatures displayed in°C,°F, or Kelvin (K)

Fluke 80PK-25 SureGrip ™ Piercing Temperature Probe See page 169

• Three year warranty Powerful data logging capabilities The Fluke 53 II B and 54 II B can log up to 500 points of data to internal memory. • User-adjustable recording intervals • Real-time clock captures the exact event time • Recall function lets logged data be easily reviewed • Download data to optional FlukeView ® PC software

Fluke 80PK-27 SureGrip ™ Industrial Surface Temperature Probe See page 169

Fluke 54 II B

Fluke 53 II B

Fluke 51 II

Fluke 80PK-10 Pipe Clamp Temperature Probe See page 169

Fluke 52 II

Specifications

51 II

52 II

53 II B

54 II B

Thermocouple types Number of inputs

J,K,T,E Single

J,K,T,E

J,K,T,E,N,R,S J,K,T,E,N,R,S

Dual

Single

Dual

Time stamp

Relative Time Relative Time Time of Day

Time of Day

Splash/Dust resistant

l

l

l

l

Dual display with backlight Min/Max/Avg recording (T 1 -T 2 ) True differential Data logging up to 500 points IR data port for interface to PC Compatible with FlukeView ® Software

l

l

l

l

l

l

l

l

- - -

-

l

l

- -

Included Accessories Fluke 50 Series Thermometers: Impact

l

l

l

l

-

-

l

l

Absorbing Holster, Two Bead Probe Thermocouples 80PK-1 (54 and 52 only), One Bead Probe Thermocouple, 80PK-1 (51 and 53 only). Fluke FoodPro (FP): AA Battery

Battery life

1000 hours typical, AA 173 mm × 86 mm × 38 mm

Size (HxWxD)

Weight

0.4 kg

Temperature range and accuracy J-type Thermocouples

and Quick Start Guide. Ordering Information FLUKE 51 II

-210°C to 1200°C -200°C to 1372°C -250°C to 400°C -150°C to 1000°C -200°C to 1300°C

K-type Thermocouples T-type Thermocouples E-type Thermocouples N-type** Thermocouples

Single Input Digital Thermometer Dual Input Digital Thermometer Single Input Digital Thermometer with Data Logging Dual Input Digital Thermometer with Data Logging

FLUKE 52 II FLUKE 53 II B

R** and S-type** Thermocouples

0°C to 1767°C

Temperature accuracy above –100°C: J, K, T, E, and N-type**

±[ 0.05% + 0.3°C ] ±[ 0.05% + 0.4°C ]

R** and S-type**

Temperature accuracy below –100°C: J, K, E, and N-types

FLUKE 54 II B

±[ 0.20% + 0.3°C ] ±[ 0.50% + 0.3°C ]

T-type

FLUKE FP FoodPro™ Food Safety Thermometer

C ontact your local distributor for price and availability. fluke.co/wtb

fluke.co/thermometers

Infrared Thermometers

51

Made with FlippingBook Learn more on our blog