Fluke 50 Series II Thermometers Lab accuracy in a field thermometer
Recommended Accessories
The Fluke 50 Series II Contact Thermometers offer fast response and laboratory accuracy in a rugged handheld test tool • Laboratory accuracy: ±(005% + 03°C) • Large backlit dual display • Min/Max/Avg • Electronic offset function maximises overall accuracy • Supports a wide range of thermocouple types • Temperatures displayed in°C,°F, or Kelvin (K)
Fluke 80PK-25 SureGrip ™ Piercing Temperature Probe
• Three year warranty Powerful data logging capabilities The Fluke 53 II B and 54 II B can log up to 500 points of data to internal memory • User-adjustable recording intervals • Real-time clock captures the exact event time • Recall function lets logged data be easily reviewed • Download data to optional FlukeView ® PC software
Fluke 80PK-27 SureGrip ™ Industrial Surface Temperature Probe
Fluke 54 II B
Fluke 53 II B
Fluke 51 II
Fluke 80PK-10 Pipe Clamp Temperature Probe
Fluke 52 II
Specifications
51 II
52 II
53 II B
54 II B
Thermocouple types Number of inputs
J,K,T,E Single
J,K,T,E
J,K,T,E,N,R,S J,K,T,E,N,R,S
Dual
Single
Dual
Time stamp
Relative Time Relative Time Time of Day
Time of Day
Splash/Dust resistant
l
l
l
l
Dual display with backlight Min/Max/Avg recording (T 1 -T 2 ) True differential Data logging up to 500 points IR data port for interface to PC Compatible with FlukeView ® Software
l
l
l
l
l
l
l
l
- - -
-
l
l
- -
Included Accessories Fluke 50 Series Thermometers: Impact
l
l
l
l
-
-
l
l
Absorbing Holster, Two Bead Probe Thermocouples 80PK-1 (54 and 52 only), One Bead Probe Thermocouple, 80PK-1 (51 and 53 only) Fluke FoodPro (FP): AA Battery and Quick Start Guide Ordering Information FLUKE 51 II Single Input Digital Thermometer FLUKE 52 II Dual Input Digital Thermometer
Battery life
1000 hours typical, AA 173 mm × 86 mm × 38 mm
Size (HxWxD)
Weight
04 kg
Temperature range and accuracy J-type Thermocouples
-210°C to 1200°C -200°C to 1372°C -250°C to 400°C -150°C to 1000°C -200°C to 1300°C
K-type Thermocouples T-type Thermocouples E-type Thermocouples N-type** Thermocouples
R** and S-type** Thermocouples
0°C to 1767°C
Temperature accuracy above –100°C: J, K, T, E, and N-type**
FLUKE 53 II B
Single Input Digital Thermometer with Data Logging Dual Input Digital Thermometer with Data Logging
±[ 005% + 03°C ] ±[ 005% + 04°C ]
R** and S-type**
Temperature accuracy below –100°C: J, K, E, and N-types
FLUKE 54 II B
±[ 020% + 03°C ] ±[ 050% + 03°C ]
T-type
FLUKE FP FoodPro™ Food Safety Thermometer