VenaFlow ® Elite S
VenaFlow Elite mimics ambulation and reduces DVT rates
Inflation Cycle indicator
S Mode Operation button
1
5
8
7
1
Battery Indicator *Note: Not all VenaFlow Elite Systems contain a battery
Patient Compliance counter
2
6
6
2
Patient Compliance counter reset push button
Single/Dual Leg operation indicator
3
7
ON/OFF/RESET push button
S Mode Operation indicator
3
5
4
8
4
Symbol Definitions
See VenaFlow Elite System operator’s manual
Power on/off button and alarm reset
Tube alarm
Dual calf/thigh
S Mode Operation
Call for service
Battery
Single calf/thigh
Inflation cycle indication (Bars indicate cuffs are inflating)
Compliance monitor reset
Lock mode
Dual foot
Visual and audio compliance alarm enabled
C
Visual only compliance alarm enabled
Single foot
Bed hanger release
1. Set up Pump
Graphical display
Pump indicator lights (green = on, flashing red = alarm)
• Press bed hanger release on the back of the pump and gently pull out bed hanger hook to the desired width. • Connect tubing to the pump. Plug pump into electrical outlet.
Telescoping bed hanger hook
2. Apply Cuff
• The VenaFlow Elite system will automatically detect the type of cuff and the number of cuffs attached and apply appropriate pressures. Cuffs must be attached prior to powering on the service. • Be sure to secure cuff straps snug but not tight. When using the calf cuff and thigh cuff, rotation of the aircell on the leg does not affect performance of the system.**
Calf or Thigh Cuff: For varied patient sizes, trim for proper, snug fit. • Apply cuff snugly with the tube pointed toward the foot. Aircell can be orientated to patient and nursing preference (posterior, lateral, anterior, or medial).**
Foot Cuff: • Apply foot cuff snugly with the aircell centered on bottom of foot and with the tube pointed to the left. Foot cuffs are only for use in standard rapid mode.
www.DJOglobal.eu
3. Connect System
4. Standard Rapid Mode Operation
Connect cuffs to the tubing that is attached to the pump.
• Press ON/OFF/RESET button. • Cuff inflation alternates between the two legs every 30 seconds. • Distal aircell inflates first and the proximal aircell follows. • Pressures settle at 45mmHg ± 15%. (Foot Cuff peak ~130 mmHg.) • After six seconds the cuff deflates. • Alarm will sound if the system is not functioning properly. 6. Locking in Standard Rapid or S Mode • To lock in standard rapid mode, make sure the device is in standard rapid mode, then press and hold the S mode button for 5 seconds. Do the same to unlock it. • To lock in S mode, make sure the device is in S mode and press and hold the S mode button for 5 seconds. Do the same to unlock it. • Once the system is locked in either standard or S mode, the lock symbol will appear on the screen.
5. S Mode Operation • When powered on, the VenaFlow Elite System will default to standard rapid inflation mode. If a slower inflation is desired, select the S mode operation button. • Once selected, both cuffs will inflate simultaneously once per minute. • Both cuffs will inflate and compress for a total of 10 seconds. • While in S mode the icon will appear in the top center of the graphical display. The device will remain in S mode until user presses the S mode operation button again. This button allows user to toggle between standard rapid inflation mode and S mode.
Check Tubes Alarm (Kinked or Disconnected Tube)
Call For Service Alarm (Ship back to DJO for repair)
Alarm Reset • To reset any alarm, press the center ON/OFF/RESET button and take steps to correct the alarm if necessary. • Note: Pressing ON/OFF/RESET following alarm only resets the alarm. The device will continue to run and will not shut down. Alarm will continue at next cycle if not corrected.
Intended Use/Indications The VenaFlow Elite System is intended as a prophylaxis for deep vein thrombosis (DVT). Contraindications
The VenaFlow Elite System should not be used by persons with known or suspected deep vein thrombosis, severe congestive heart failure, pulmonary edema, thrombophlebitis, severe arteriosclerosis, or active infection. Do not use on extremities which are not sensitive to pain, where cuff will interfere with gangrene, on patients with vein ligation or recent skin grafts, or extreme deformity of the leg. Do not use the VenaFlow Elite System where increased venous or lymphatic return is undesirable. Warning and Precautions • The VenaFlow Elite cuffs are designed for single patient use only. • Risk of explosion if used in the presence of flammable anaesthetics. • The equipment or system should not be used adjacent to or stacked with other equipment and, if adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the configuration in which it will be used. • Medical Electrical Equipment needs special precautions regarding EMC. Portable and Mobile RF Communications Equipment can be affected by other Medical Electrical Devices. • Cuffs used in combination with warming devices may cause skin irritation. Regularly check for patient comfort, compliance and skin irritation. • Special attention should be given to those patients with neuropathies or tissue viability problems (i.e. diabetes, arterial or venous insufficiencies). • To prevent extremity compartment syndrome, special attention should be given to patients who are positioned in the supine lithotomy position for extended lengths of time. This includes patients with or without compression cuffs. • If you experience pain, swelling, sensation changes or any unusual reactions while using this device, consult your medical professional immediately.
FEATURES & BENEFITS Features
Benefits
Low Profile, Lightweight Design
Easily stored, easily transported
Telescoping Bed Hanger
Extends to accommodate up to 9cm
Automatic Single/Dual Leg Detection
System automatically detects and icon(s) appear on screen
Automatic Cuff Detection
System automatically identifies and adjusts pressure based on cuffs attached prior to turning pump on
Preset Pressures & Alarms
No adjustments necessary
Compliance Monitor/Alarm
Available with compliance counter plus alarm notification for non-compliance
One Pump for Calf, Thigh, & Foot Cuffs
Provides for ease of use and minimizes inventory
Soft, Breathable Cuffs
Assists in increasing patient comfort and compliance
Toggle between Standard Mode (rapid) and S Mode (slower, sustained inflation). Can also lock into Standard or S Mode by pressing button for five seconds
S Mode Operation
ORDERING INFORMATION
Max. Circumference
Part Number
Description
Quantity
30BI-S
VenaFlow Elite System with S mode (International)
1
N/A
30BI-SB
VenaFlow Elite System battery version with S mode (International)
1
N/A
3040
VenaFlow Elite Calf Cuff
Pair
48cm
3042
VenaFlow Elite XL Calf Cuff
Pair
56cm
3043
VenaFlow Elite Bariatric Calf Cuff
Pair
76cm
3045
VenaFlow Elite Thigh Cuff
Pair
74cm
3046
VenaFlow Elite Foot Cuff
Pair
Universal
3050
VenaFlow Elite Foam Calf Cuff
Pair
48 cm
3008
Tube Assembly, 168 cm
Each
3008XL
Tube Assembly, 260 cm
Each
3008XXL
Tube Assembly, 320 cm
Each
3008XXXL
Tube Assembly, 380 cm
Each
SYSTEM REPLACEMENT PARTS Part Number Description 3071 Bed Hanger 3072 Tube Attachment Tag 3073 Fuse