Venaflow Brochure

VenaFlow ® Elite S

VenaFlow Elite mimics ambulation and reduces DVT rates

Inflation Cycle indicator

S Mode Operation button

1

5

8

7

1

Battery Indicator *Note: Not all VenaFlow Elite Systems contain a battery

Patient Compliance counter

2

6

6

2

Patient Compliance counter reset push button

Single/Dual Leg operation indicator

3

7

ON/OFF/RESET push button

S Mode Operation indicator

3

5

4

8

4

Symbol Definitions

See VenaFlow Elite System operator’s manual

Power on/off button and alarm reset

Tube alarm

Dual calf/thigh

S Mode Operation

Call for service

Battery

Single calf/thigh

Inflation cycle indication (Bars indicate cuffs are inflating)

Compliance monitor reset

Lock mode

Dual foot

Visual and audio compliance alarm enabled

C

Visual only compliance alarm enabled

Single foot

Bed hanger release

1. Set up Pump

Graphical display

Pump indicator lights (green = on, flashing red = alarm)

• Press bed hanger release on the back of the pump and gently pull out bed hanger hook to the desired width. • Connect tubing to the pump. Plug pump into electrical outlet.

Telescoping bed hanger hook

2. Apply Cuff

• The VenaFlow Elite system will automatically detect the type of cuff and the number of cuffs attached and apply appropriate pressures. Cuffs must be attached prior to powering on the service. • Be sure to secure cuff straps snug but not tight. When using the calf cuff and thigh cuff, rotation of the aircell on the leg does not affect performance of the system.**

Calf or Thigh Cuff: For varied patient sizes, trim for proper, snug fit. • Apply cuff snugly with the tube pointed toward the foot. Aircell can be orientated to patient and nursing preference (posterior, lateral, anterior, or medial).**

Foot Cuff: • Apply foot cuff snugly with the aircell centered on bottom of foot and with the tube pointed to the left. Foot cuffs are only for use in standard rapid mode.

www.DJOglobal.eu

3. Connect System

4. Standard Rapid Mode Operation

Connect cuffs to the tubing that is attached to the pump.

• Press ON/OFF/RESET button. • Cuff inflation alternates between the two legs every 30 seconds. • Distal aircell inflates first and the proximal aircell follows. • Pressures settle at 45mmHg ± 15%. (Foot Cuff peak ~130 mmHg.) • After six seconds the cuff deflates. • Alarm will sound if the system is not functioning properly. 6. Locking in Standard Rapid or S Mode • To lock in standard rapid mode, make sure the device is in standard rapid mode, then press and hold the S mode button for 5 seconds. Do the same to unlock it. • To lock in S mode, make sure the device is in S mode and press and hold the S mode button for 5 seconds. Do the same to unlock it. • Once the system is locked in either standard or S mode, the lock symbol will appear on the screen.

5. S Mode Operation • When powered on, the VenaFlow Elite System will default to standard rapid inflation mode. If a slower inflation is desired, select the S mode operation button. • Once selected, both cuffs will inflate simultaneously once per minute. • Both cuffs will inflate and compress for a total of 10 seconds. • While in S mode the icon will appear in the top center of the graphical display. The device will remain in S mode until user presses the S mode operation button again. This button allows user to toggle between standard rapid inflation mode and S mode.

Check Tubes Alarm (Kinked or Disconnected Tube)

Call For Service Alarm (Ship back to DJO for repair)

Alarm Reset • To reset any alarm, press the center ON/OFF/RESET button and take steps to correct the alarm if necessary. • Note: Pressing ON/OFF/RESET following alarm only resets the alarm. The device will continue to run and will not shut down. Alarm will continue at next cycle if not corrected.

Intended Use/Indications The VenaFlow Elite System is intended as a prophylaxis for deep vein thrombosis (DVT). Contraindications

The VenaFlow Elite System should not be used by persons with known or suspected deep vein thrombosis, severe congestive heart failure, pulmonary edema, thrombophlebitis, severe arteriosclerosis, or active infection. Do not use on extremities which are not sensitive to pain, where cuff will interfere with gangrene, on patients with vein ligation or recent skin grafts, or extreme deformity of the leg. Do not use the VenaFlow Elite System where increased venous or lymphatic return is undesirable. Warning and Precautions • The VenaFlow Elite cuffs are designed for single patient use only. • Risk of explosion if used in the presence of flammable anaesthetics. • The equipment or system should not be used adjacent to or stacked with other equipment and, if adjacent or stacked use is necessary, the equipment or system should be observed to verify normal operation in the configuration in which it will be used. • Medical Electrical Equipment needs special precautions regarding EMC. Portable and Mobile RF Communications Equipment can be affected by other Medical Electrical Devices. • Cuffs used in combination with warming devices may cause skin irritation. Regularly check for patient comfort, compliance and skin irritation. • Special attention should be given to those patients with neuropathies or tissue viability problems (i.e. diabetes, arterial or venous insufficiencies). • To prevent extremity compartment syndrome, special attention should be given to patients who are positioned in the supine lithotomy position for extended lengths of time. This includes patients with or without compression cuffs. • If you experience pain, swelling, sensation changes or any unusual reactions while using this device, consult your medical professional immediately.

FEATURES & BENEFITS Features

Benefits

Low Profile, Lightweight Design

Easily stored, easily transported

Telescoping Bed Hanger

Extends to accommodate up to 9cm

Automatic Single/Dual Leg Detection

System automatically detects and icon(s) appear on screen

Automatic Cuff Detection

System automatically identifies and adjusts pressure based on cuffs attached prior to turning pump on

Preset Pressures & Alarms

No adjustments necessary

Compliance Monitor/Alarm

Available with compliance counter plus alarm notification for non-compliance

One Pump for Calf, Thigh, & Foot Cuffs

Provides for ease of use and minimizes inventory

Soft, Breathable Cuffs

Assists in increasing patient comfort and compliance

Toggle between Standard Mode (rapid) and S Mode (slower, sustained inflation). Can also lock into Standard or S Mode by pressing button for five seconds

S Mode Operation

ORDERING INFORMATION

Max. Circumference

Part Number

Description

Quantity

30BI-S

VenaFlow Elite System with S mode (International)

1

N/A

30BI-SB

VenaFlow Elite System battery version with S mode (International)

1

N/A

3040

VenaFlow Elite Calf Cuff

Pair

48cm

3042

VenaFlow Elite XL Calf Cuff

Pair

56cm

3043

VenaFlow Elite Bariatric Calf Cuff

Pair

76cm

3045

VenaFlow Elite Thigh Cuff

Pair

74cm

3046

VenaFlow Elite Foot Cuff

Pair

Universal

3050

VenaFlow Elite Foam Calf Cuff

Pair

48 cm

3008

Tube Assembly, 168 cm

Each

3008XL

Tube Assembly, 260 cm

Each

3008XXL

Tube Assembly, 320 cm

Each

3008XXXL

Tube Assembly, 380 cm

Each

SYSTEM REPLACEMENT PARTS Part Number Description 3071 Bed Hanger 3072 Tube Attachment Tag 3073 Fuse