PAAS SB V4.2

Industrial Grey PVC-U Pipe And Fittings pH and ORP

DryLoc pH and ORP Electrodes

Standard Electrode

Specifications  Type 2724-2726

Applications  Toxics Destruction

 0-14pH, +2000 Mv ORP  Ryton body, PE junction  Use fittings for in-line applications or 3/4 in. NPT or ISO  Suitable for submersible applications  DryLoc pre-amplifier connection with gold plated pins

 Water and Waste Water Treatment  Heavy Metal Removal and Recovery  Process Control  Effluent Monitoring  Neutralisation systems  Commercial Pools & Spas  Aquatic Animal Life Support Systems  Sanitization Systems

 Scrubber control  Surface Finishing

Overview: Standard 2724 - 2726

The DryLoc connector with corrosion resistant gold plated contacts readily connects the sensor to the mating 2760 pre-amplifier or the 2750 sensor electronics. The robust Ryton® threaded sensor body and choice of flat pH, bulb pH, or flat ORP sensing elements provides broad range of chemical compatibility for a wide variety of applications.

Differential Electrode

Specifications  Type 2764-2767

Applications  Toxics Destruction

 0-14pH, +2000 mV ORP  Ryton body, PTFE junction  Use sensor 1 inch threads for mounting  DryLoc pre-amplifier connection with gold plated pins  For use with 2750/2760 preamplifiers

 Water and Waste Water Treatment  Heavy Metal Removal and Recovery  Scrubbers

 Plant Effluent  Plating Baths

 Coagulation and Flocculation  Harsh Chemical Applications  Textile Dye Process  Surface Finishing

Overview: 2764 Differential pH & ORP These differential electrodes use field-proven 3-electrode differential technique: the pH and reference electrodes are measured against a ground elec- trode, ensuring a steady and stable signal. A key feature is the reference electrode which is protected in a glass half-cell embedded in the reference chamber and is protected from compounds that may contain sulfides (S2-) and metals. To ensure long service life, the reference features a refillable electrolyte chamber and a replaceable equitransferant salt bridge. The patented porous PTFE reference junction resists fouling, clogging and chemical attack. Other elements of the design are the solution ground, the pH/ORP electrodes, and the temperature element. The solution ground eliminates noisy meas- urements by draining electrical current away from the reference electrode. The pH/ORP electrodes are designed with a flat or bulb measurement surface, and a temperature device that is positioned at the tip of the measurement surface, making the temperature response of T95% less than 1 minute. Vari- ous temperature devices offered include 3 K Ω , 300 Ω , or PT1000 RTD. The electrodes are used with the Signet 2750 Sensor Electronics, which provide a blind 4 to 20 mA output or use the digital (S3L) output to connect to Signet’s 8900 Multi-Parameter Controller. The electrodes can also be used with the Model 2760 pre-amplifier to connect to the Signet’s 8750 instruments.

214 PAAS Source Book

www.paas.com.au