PAAS SB V4.2

Pressure

Pressure Sensor Type 2450

 Great Chemical compatibility due to PVDF Body, use in highly corrosive media applications

Pressure Sensor Type 2450

Applications  Chemical Processing  Pressure Regulation/Monitoring

Specifications  -0.1-0.7 bar (-1.5-10 psi) - U  0.41-3.4 bar (-6.0-50 psi) - L  0.96-17.2 bar (-14.6-250 psi) - H  PVDF, ceramic  1/2 in. union, dual threaded  4.6m Cable

 Irrigation Systems  Water Management  Level or Depth Sensing  Pump Protection  HVAC  Wastewater  Scrubber Systems

Overview: 2450 Pressure Sensor

The 2450 Pressure Sensor has a one-piece injection moulded PVDF body and ceramic diaphragm for superior compatibility in corrosive liquids. Three pressure range versions allow for optimal resolution matched to your sensing needs. Solid state circuitry eliminates drift (no internal potentiometers.) Built-in temperature compensation provides outstanding accuracy over wide temperature ranges.

Pressure Sensor Type 2450 - Order Guide

 Select Sensor based on pressure range , Frequency output used with transmitter or Blind output for use with PLC

Range

CODE

REF #

Pressure Sensor

For use with 9900 Transmitter

0 to 10 PSI

3-2450-3U 159 000 683

For use with 9900 Transmitter

0 to 50 PSI

3-2450-3L 159 000 682

For use with 9900 Transmitter

0 to 250 PSI

3-2450-3H 159 000 681

Blind 4-20mA output

0 to 10 PSI

3-2450-7U 159 000 906

Blind 4-20mA output

0 to 50 PSI

3-2450-7L 159 000 908

Blind 4-20mA output

0 to 250 PSI

3-2450-7H 159 000 910

 Select Transmitter based on installation Method

Transmitter

Field Mount

CODE

Field Mount Transmitter Type 9900

3-9900-1

Mounting Kit (Required)

3-8050

Panel Mount

CODE

Panel Mount Transmitter

3-9900-1P

Integral Mount

CODE

Integral Mount

3-9900-1

Mounting Kit ( Required)

3-8052

Angle Mount Kit (optional

3-9900.396

1300 PIPING (1300 747 464)

V 4.1

PAAS Source Book 219