Preset parameter settings The EPT is operational as a standalone cordless screwdriver that allows you to program torque and fastening settings on the tool’s display. The EPC-10 controller provides you the ability to program fastening settings and advance functions like the Job Manager. Each preset setting has the following programmable parameters:
PRESET SETTINGS
PROGRAMMABLE PARAMETERS
Tightening Mode
Torque control + angle monitoring (TC/AM) Angle control + torque monitoring (AC/TM)
Torque
Target torque, min/max torque, snug torque, seating torque, torque compensation
Angle
Target angle, min/max angle, free speed angle
Speed
Target speed, Free speed, Ramp up speed
Time
Soft start time, torque rising time, torque holding time
Thread Tapping
Target torque, min/max thread torque, speed, angle start
Screw Counting
Cycle start signal, time limit, total screw count, count port signal type
Sequence control Mountz DC control tools are easy to program and can remember up to 30 process sequences with 20 program steps. The tool gives you the flexibility you need to carry out varied and complicated manufacturing plans.
PROGRAM SETTINGS ON THE CORDLESS SCREWDRIVERS
PROGRAM SETTINGS ON THE EPC-10 CONTROLLER
PRESET NUMBER SETTING VALUE UNIT OF SETTING
BATTERY TARGET TORQUE C. TORQUE FUNCTION KEY
CHANGE TO INFORMATION AND SETTING MODE
Example with sample program of sequence control
STEP 1 Input Detect workpiece arrival on the position
STEP 2 Delay Time delay
STEP 3 Output Lock the
STEP 4 Tightening Tightening total 7 with Preset #12
STEP 5 Output Release the workpiece from an air cylinder lock
0.5 seconds to the next step
workpiece with an air cylinder
Note: Can configure up to 15 presets and 15 models, consisting of up to 20 steps for each model.