44P I/O Wiring Box It provides easy and convenient wiring for 12 inputs and outputs for a ECD, ECTD or ADC controller by sharing one single 24V power source (Input power: 24VDC 1A). A I/O Cable is needed to connect to a controller.
1A
OUT 1
1A
OUT 2
1A
OUT 3 OUT COM
I/O Wiring Box Item #310055 Note: It requires an AC Adapter, Item #310102
I/O Cable 3m (44P male to 25P male) Item #310057
D_SUB 44P
In 1
In 10
Out 4
–
Out Com
1
10
19
28
37
In 2
In 11
Out 5
Out Com
–
2
11
20
29
38
In 3
In 12
Out 6
Out Com
–
3
12
21
30
39
In 4
–
Out 7
24V+
–
4
13
22
31
40
In 5
In Com
Out 8
24V+
–
5
14
23
32
41
In 6
In Com
Out 9
24V+
–
6
15
24
33
42
In 7
Out 1
Out 10
–
–
7
16
25
34
43
In 8
Out 2
Out 11
Out Com
–
8
17
26
35
44
In 9
Out 3
Out 12
Out Com
9
18
27
36
23