Overload Protection & Safety Devices

Tsubaki ® : The choice for overload protection and safety

TL SERIES

Traditional machine protection. Friction-type construction. Slip-torque setting is done by simply tightening the adjusting nut or bolts. Competitively priced and easy to use.

SELECTION

Select based on torque required, rpm, and shaft diameter. Bushing Length selection should be equal to or shorter than width of center member (sprocket, etc.):

ROUGH STOCK BORE

TORQUE RANGE (LBS. - FT.) 0.7 ~ 1.5 2.2 ~ 7.2 5.0 ~ 15 2.2 ~ 5.0 5.0 ~ 20 10 ~ 40 7.0 ~ 15 15 ~ 55 25 ~ 110 15 ~ 36 35 ~ 155 65 ~ 310 36 ~ 87 85 ~ 420 165 ~ 800 289 ~ 940 435 ~ 1,370 651 ~ 1,960

MAXIMUM RPM

MAX. BORE W.STD. KW

WT (LBS.)

MODEL

BUSHING LENGTHS

D DH

L

S (MAX.)

TL200-1L TL200-1 TL200-2 TL250-1L TL250-1 TL250-2 TL350-1L TL350-1 TL350-2 TL500-1L TL500-1 TL500-2 TL700-1L TL700-1 TL700-2 TL10-16 TL10-24 TL14-10

1800

0.28

0.55

0.150, 0.236

2.0 0.95 1.14 0.276 0.44

0.177, 0.256

1800

0.39

0.88

2.5 1.38 1.88 0.354 1.32

1800

0.67

1.00

0.177, 0.256, 0.374 3.5 1.65 2.44 0.630 2.65

1800

0.78

1.75

0.256, 0.374

5.0 2.56 3.0 0.630 7.72

1800

1.18

2.63

0.374, 0.492

7.0 3.75 3.86 1.142 18.5

1000

1.18

2.84

0.492, 0.610, 0.768 10 3.94 4.53 0.945 46.3

500

1.57

3.94

0.610, 0.768, 0.925 14 5.71 5.91 1.142 115

TL14-15 1,446 ~ 2,890 TL20-6 1,807 ~ 3,615 TL20-12 3,400 ~ 6,870

500

1.97

5.12

0.610, 0.768, 0.925 20 7.28 6.89 1.22 258

TL200~TL350

TL500~TL700

TL10~TL20

More information at www.ustsubaki.com

13