A+A Regulations

Stand Construction / Structural Measures

Additionally for Halls 1. 6. 7a. 8a and 8b:

• Areas enclosed on all sides shall not be permissible for people to stay in as a mat- ter of principle. This also applies to the tensioned fabric ceilings fit for sprinkler in- stallation. Excluded are rooms which are only en- tered by a limited group of people, individ- ually and only for a short length of time, such as storage or utility rooms, un- manned cloakrooms, rooms with lockers, for example. • All areas (meeting rooms, office rooms, ground floors in multi-storey stands, etc.) are only permissible in an open layout in order to integrate them into the ventilation. Here a complete air exchange is to be achieved. In structural terms this objective is achieved if the values stated in the follow- ing table are implemented taking account of the maximum construction heights per- mitted:

Free opening to the aisle [m²] per 1 m front length

Depth of roof- ing [m]

Required ceil- ing height [m]

16 17 18 19

6.4 6.8 7.2 7.6

5.6

5.95

6.3

6.65

20 7 TAB: one-sided ventilation acc. to ASR A3.6 Lüftung (Technical Rules for Workplaces, Ventilation). Room occupancy acc. to SBauVO (Special Construction Ordinance). 8.0 Areas that do not fulfil these requirements and where a complete air exchange is not achieved must be alternatively equipped with a compact air filter system guarantee- ing HEPA-filter efficiency (H13 or H14) or fresh air supply must be ensured subject to technical feasibility. Fans and filterless air ventilation systems are not sufficient. Ap- proved filter systems can be obtained via the OOS. • Exhibition areas have to be designed in such a way that at least 30% of them are accessible. Deviating, event-specific regu- lations are possible. These can be found in the stand construction portal under "Spe- cifics" of the corresponding event.

All halls (excluding Hall 7.0 – 7.2):

Free opening to the aisle [m²] per 1 m front length

Depth of roof- ing [m]

Required ceil- ing height [m]

1 2 3 4 5 6 7 8 9

2.5 2.5 2.5 2.5 2.5 2.5 2.8 3.2 3.6 4.0 4.4 4.8 5.2 5.6 6.0

0.35

0.7

1.05

There is no requirement for maximum numbers of people on stands. The decisive factor is that the persons present can maintain a minimum distance of 1.5 m from each other. Depending on the 7-day incidence, the hygiene distances in groups may be undercut, taking into account the contact limits. In addition, hygiene distanc- es can be reduced by separations such as walls. The installation of distance markings in highly frequented areas of the stand is recommended.

1.4

1.75

2.1

2.45

2.8

3.15

10 11 12 13 14 15

3.5

3.85

4.2

4.55

4.9

5.25

• Catering at the stands depends on the current incidence level at runtime. As a matter of principle, the operators of gas- tronomy and catering services must draw up their own hygiene and infection protec- tion concept based on the CoronaSchVO and its annexes. They are responsible for the content and ensure implementation on their own responsibility.