COMPRESORES SEMIHERMÉTICOS
COMPRESORES SEMIHERMETICOS DORIN DE 2 CILINDROS. SERIES H11. MULTIREFRIGENTE HFC+A2L
R454C/R455A/R449A/R448A/R452A/R404A/R134a/R513A
N Novedad
Rendimiento en (W) a temperatura de evaporación de:
m 3 /h 50 Hz
MODELO
C.V.
Refrigerante
€/Und
CÓDIGO
5º C
0º C -5º C -10º C -25º C -35º C
R134a (R513A)
6.700 5.390 4.270 3.320 1.340
-
H-281-CC
3 11,64
R449A (R448A) 10.970 8.950 7.200 5.720 2.580 1.320 R454C 10.180 8.320 6.700 5.310 2.300 1.630
1.930,00
H281CC
R134a (R513A) R449A (R448A) R134a (R513A) R449A (R448A) R454C
7.780 6.270 4.970 3.880 1.580
-
H-281-SB
3 13,23
- - - -
- - - -
- - - -
6.410 2.950 1.540 6.140 2.740 1.970 6.600 3.030 1.570 5.840 2.550 1.820 -
1.990,00
H281SB
7.710 6.220 4.930 3.840 1.550
H-281-CS
3 13,23
2.000,00
H281CS
R454C
Para rendimiento con otros refrigerantes consultar software de Dorin
Refrigeración adicional ó reducción de la temperatura del gas de aspiración. Refrigeración adicional y reducción de la temperatura del gas de aspiración.
Rendimientos indicados bajo condiciones EN12900, para temperatura de condensación +45ºC, recalentamiento 10K y subenfriamiento 3K. Temperaturas en punto medio para gases mezcla. Los compresores de la serie H11 se suministran con termistor (aunque es posible se suministre con protección termik)
COMPRESORES SEMIHERMETICOS DORIN DE 2 CILINDROS. SERIE H2. MULTIREFRIGENTE HFC+A2L
R454C/R455A/R449A/R448A/R452A/R404A/R134a/R513A
N Novedad
Rendimiento en (W) a temperatura de evaporación de:
m 3 /h 50 Hz
Refrigerante
€/Und
CÓDIGO
MODELO
C.V.
5º C
0º C -5º C -10º C -25º C -35º C
R134a (R513A) R449A (R448A)
8.420 6.770 5.350 4.150 1.630
-
H-290-CS
3 14,74
- -
- -
- -
7.510 3.470 1.830 6.670 2.920 2.090
2.170,00
H290CS
R454C
R134a (R513A)
8.430 6.780 5.350 4.150 1.680
-
H-300-CC
3 14,74
R449A (R448A) 13.940 11.390 9.190 7.320 3.390 1.800 R454C 12.520 10.210 8.210 6.500 2.830 2.020
2.220,00 H2D0360
R134a (R513A) R449A (R448A)
9.150 7.350 5.800 4.490 1.750
-
H-300-CS
3 15,94
- -
- -
- -
8.270 3.880 2.100 7.710 3.490 2.550
2.220,00
H300CS
R454C
R134a (R513A)
9.140 7.330 5.770 4.470 1.800
-
H-350-CC
3,5 15,94
R449A (R448A) 15.400 12.640 10.250 8.220 3.880 2.100 R454C 14.410 11.830 9.580 7.650 3.470 2.530
2.220,00 H2D0380
R134a (R513A) R449A (R448A) R134a (R513A) R449A (R448A) R454C
9.940 7.980 6.290 4.870 1.900
-
H-350-SB
3,5 17,53
- - - - - - - - - -
- -
- -
- -
4.380 2.390 3.730 2.710
2.220,00 H2E0360
9.960 8.010 6.320 4.900 1.960
-
H-380-CC
4 17,53
14.060 11.410 9.160 4.370 2.410 12.730 10.300 8.210 3.710 2.710
2.580,00 H2E0380
R454C
R134a (R513A) 10.990 8.820 6.950 5.370 2.090
-
H-380-SB
4 19,53
R449A (R448A)
- - - - - -
- - - - - -
- -
4.860 2.720 4.100 3.010
2.290,00
H380SB
R454C
R134a (R513A) 11.160 8.960 7.060 5.460 2.120
-
H-390-CS
4 19,53
R449A (R448A)
9.910 4.810 2.740 8.950 4.110 3.020
2.580,00 H2F0380
R454C
R134a (R513A) 13.090 10.490 8.260 6.380 2.480
-
H-392-CS
4,5 23,31
R449A (R448A)
- -
5.770 3.060 4.900 3.550
2.680,00 H2G0400
R454C
Para rendimiento con otros refrigerantes consultar software de Dorin
Refrigeración adicional ó reducción de la temperatura del gas de aspiración. Refrigeración adicional y reducción de la temperatura del gas de aspiración.
Rendimientos indicados bajo condiciones EN12900, para temperatura de condensación +45ºC, recalentamiento 10K y subenfriamiento 3K. Temperaturas en punto medio para gases mezcla. Los compresores de la serie H2 se suministran con termistor (aunque es posible se suministre con protección termik)
Abril 2025
72
Made with FlippingBook Digital Publishing Software