TARIFA GRUPO GSF 2024

UNIDADES CONDENSADORAS SEMIHERMÉTICAS

SERIE H33

m 3 /h 50 Hz

Rendimiento en (W) a temperatura de evaporación de: 0º C -5º C -10º C -25º C -30º C

MODELO

C.V.

Refrigerante

€/Und

CÓDIGO

5º C

R134a (R513A) 16.490 13.680 11.200 9.000

4.100 7.190 7.350 4.130 7.320 7.520 4.280 8.070 8.070

-

E-AU-H705CS

7 31,88

R449A (R448A) R452A (R404A)

- -

- -

- -

13.690

6.350,00 E-AU-H705CS

5.560 5.730

-

R134a (R513A) 16.800 13.900 11.350 9.130

-

E-AU2-H705CS

7 31,88

R449A (R448A) R452A (R404A)

- -

- -

- -

14.070 13.990

6.810,00 E-AU2-H705CS

5.650 5.840

R134a (R513A) 18.440 15.110 12.200 9.670 R449A (R448A) 27.670 23.120 19.150 15.710

-

E-AU2-H755CC

7,5 31,88

7.390,00 E-AU2-H755CC

6.250 6.170

R452A (R404A)

-

23.010 19.210 15.800

Refrigeración adicional ó reducción de la temperatura del gas de aspiración.

Rendimientos indicados bajo condiciones EN13215 con temperatura ambiente +35ºC, recalentamiento 10K y subenfriamiento 3K. Temperaturas en punto medio para gases mezcla.

SERIE H35

m 3 /h 50 Hz

Rendimiento en (W) a temperatura de evaporación de: 0º C -5º C -10º C -25º C -30º C

MODELO

C.V.

Refrigerante

€/Und

CÓDIGO

5º C

R134a (R513A) 18.690 15.560 12.770 10.300

4.730 8.140 8.400 4.890 8.920 9.310

-

E-AU2-H751CS

7,5 38,06

R449A (R448A) R452A (R404A)

- -

- -

- -

15.350 15.150

7.310,00 E-AU2-H751CS

6.310 6.580

R134a (R513A) 21.070 17.330 13.980 11.100 R449A (R448A) 30.740 25.830 21.450 17.620

-

E-AU2-H1002CC 10 38,06

7.890,00 E-AU2-H1002CC

6.830 7.160

R452A (R404A)

-

26.250 21.950 18.070

Refrigeración adicional ó reducción de la temperatura del gas de aspiración.

Rendimientos indicados bajo condiciones EN13215 con temperatura ambiente +35ºC, recalentamiento 10K y subenfriamiento 3K. Temperaturas en punto medio para gases mezcla.

SERIE H41

m 3 /h 50 Hz

Rendimiento en (W) a temperatura de evaporación de: 0º C -5º C -10º C -25º C -30º C 5º C

MODELO

C.V.

Refrigerante

€/Und

CÓDIGO

R134a (R513A) 22.200 18.360 14.960 11.990

5.450

-

R449A (R448A) R452A (R404A)

- -

- -

- -

19.110 18.600

E-AU2-H801CS

8,5 42,81

8.120,00

E-AU2-H801CS

9.990 7.690 10.120 7.910

R134a (R513A) 24.890 20.350 16.410 12.990 R449A (R448A) 37.270 31.160 25.790 21.110 R452A (R404A) 37.510 31.360 26.090 21.360 R134a (R513A) 28.050 22.950 18.470 14.600 R449A (R448A) 43.320 36.330 30.170 24.770

5.660

-

E-AU2-H1003CC 12 42,81

8.960,00 E-AU2-H1003CC

10.590 8.060 10.830 8.280

6.250

-

E-AU2-H1501CC 15 48,82

9.690,00 E-AU2-H1501CC

12.590 9.670 12.930 10.070

R452A (R404A)

-

35.120 29.460 24.390

R134a (R513A) 27.330 22.870 18.880 15.330

7.120

-

E-AU2-H1501CS 15 56,87

R449A (R448A) R452A (R404A)

- -

- -

- -

23.450 22.960

9.280,00

E-AU2-H1501CS

12.770 9.980 13.000 10.300

R134a (R513A) 31.050 25.530 20.540 16.260 R449A (R448A) 48.650 40.910 34.100 28.100

7.000

-

E-AU2-H2001CC 20 56,87

10.300,00 E-AU2-H2001CC

14.490 11.200 14.920 11.660

R452A (R404A)

-

40.090 33.740 28.000

R134a (R513A) 33.030 27.440 22.420 18.040

8.210

-

E-AU2-H1601CS 16 63,76

R449A (R448A) R452A (R404A)

- -

- -

- -

29.440 28.760

10.800,00 E-AU2-H1601CS

15.330 11.840 15.720 12.370

R134a (R513A) 35.870 29.390 23.670 18.730 R449A (R448A) 56.230 47.100 39.060 32.040

8.060

-

E-AU4-H2201CC 22 63,76

13.100,00 E-AU4-H2201CC

16.270 12.500 17.000 13.280

R452A (R404A)

-

46.340 38.860 32.140

Refrigeración adicional ó reducción de la temperatura del gas de aspiración.

Rendimientos indicados bajo condiciones EN13215 con temperatura ambiente +35ºC, recalentamiento 10K y subenfriamiento 3K. Temperaturas en punto medio para gases mezcla.

Abril 2024

88