Mountz Power Tools Service Card Insert

Manufacturing products in a cleanroom presents many challenges. Tightening fasteners in a cleanroom environment demands specialized screwdrivers that prevent contamination and grease leakage. The Mountz cleanroom screwdrivers are manufactured using a high-grade, low-outgassing powder coat. The tools feature dynamic wear-resistant internal seals to prevent grease leakage and minimize airborne contamination. Designed for a cleanroom environment, the FG-CR cleanroom screwdriver is manufactured using a high-grade, low-outgassing powder coat. The tools feature dynamic wear-resistant internal seals to prevent grease leakage and minimize airborne contamination.

THANK YOU FOR CHOOSING MOUNTZ Your torque tool is built for precision. Regular calibration and maintenance ensure your tool delivers the accuracy your process demands. Calibration

Verify torque periodically per your quality program Calibrate if tools are dropped, damaged, or show torque drift Follow Mountz service recommendations for your tool type Preventive Maintenance

Inspect regularly for wear or looseness Keep tools clean, dry, and properly stored Service moving parts (oil changes, brush replacement, etc.) as recommended Recommended Calibration and Maintenance Cycle:

Preventive Maintenance / Service Inspect regularly for wear; replace brushes when worn Inspect regularly for wear; maintain clean, lubricated air supply Oil service required; inspect at 250k pulses, replace soft parts at 500k

Tool Family

Models

Calibration Guidance

Electric Screwdrivers (Standard / Brushless)

Calibrate every 6–12 months or per Quality Control plan

BF, NF, BFA, NFA, HF, K Series

Calibrate every 6 months or per Quality Control plan

Pneumatic Air Screwdrivers

XP Series

Calibrate per Quality Control plan

Pneumatic Pulse Tools

FLEX, FLEXS Series

PTM-20, PTM-52, PTM-92, PTM- 135, PTM-300 (various torque ranges)

Pneumatic Multipliers

Calibrate every 6–12 months

Service as needed

Automated DC Drivers

CLF Series

Verify torque when adjusting Replace brushes when worn ~50%

Motor/Gear/Grease: inspect/replace at ~1,000,000 cycles · Torque Accuracy: calibrate at ~500,000 cycles · Cable: replace at ~600,000 cycles Motor/Gear/Grease: inspect/replace at ~1,000,000 cycles · Torque Accuracy: calibrate at ~500,000 cycles · Cable: replace at ~600,000 cycles Low-maintenance brushless design; extended life cycle

Current Control Smart Electric (Non-Transducerized)

EC Series, Mini MD Series, MD Series

Calibrate every 6–12 months or per Quality Control plan

Calibrate per Quality Control plan; verify torque via built-in sensor or tool procedure

Transducerized DC Tools

ECT Series, MDT Series

Cordless Transducerized DC Tools

Calibrate per Quality Control plan; verify torque periodically

EPT Series

Calibration Price List

Contact the Mountz Customer Experience Service Team & Schedule Your Calibration Today

https://mountztorque.com/en-us/usa-service

(408) 850-9978

WANT TO VERIFY & CALIBRATE YOUR TOOLS IN-HOUSE?

LTT-Series Torque Analyzer

Validates & calibrates torque screwdrivers, wrenches & power tools Works with built-in and external Mountz sensors Data storage, graphing & USB export

EZ-TorQ III Analyzer

Compact, portable torque tester with built-in transducer Ideal for small hand tools & non-impact power tools Touchscreen interface with Mountz Data Streamer software Quick, on-the-floor tool verification

Screw RDA - Run Down Adapters

Simulates joint conditions for consistent torque readings Attaches between the tool and analyzer transducer For clockwise use; replaceable screw element

AURA - Auto Reversing Run Down Adapters

Automatically resets after each run-down Provides repeatable torque results for power tools Compact, easy to use, and ideal for frequent testing

Page 1 Page 2

www.mountztorque.com

Made with FlippingBook Annual report maker