Manufacturing products in a cleanroom presents many challenges. Tightening fasteners in a cleanroom environment demands specialized screwdrivers that prevent contamination and grease leakage. The Mountz cleanroom screwdrivers are manufactured using a high-grade, low-outgassing powder coat. The tools feature dynamic wear-resistant internal seals to prevent grease leakage and minimize airborne contamination. Designed for a cleanroom environment, the FG-CR cleanroom screwdriver is manufactured using a high-grade, low-outgassing powder coat. The tools feature dynamic wear-resistant internal seals to prevent grease leakage and minimize airborne contamination.
THANK YOU FOR CHOOSING MOUNTZ Your torque tool is built for precision. Regular calibration and maintenance ensure your tool delivers the accuracy your process demands. Calibration
Verify torque periodically per your quality program Calibrate if tools are dropped, damaged, or show torque drift Follow Mountz service recommendations for your tool type Preventive Maintenance
Inspect regularly for wear or looseness Keep tools clean, dry, and properly stored Service moving parts (oil changes, brush replacement, etc.) as recommended Recommended Calibration and Maintenance Cycle:
Preventive Maintenance / Service Inspect regularly for wear; replace brushes when worn Inspect regularly for wear; maintain clean, lubricated air supply Oil service required; inspect at 250k pulses, replace soft parts at 500k
Tool Family
Models
Calibration Guidance
Electric Screwdrivers (Standard / Brushless)
Calibrate every 6–12 months or per Quality Control plan
BF, NF, BFA, NFA, HF, K Series
Calibrate every 6 months or per Quality Control plan
Pneumatic Air Screwdrivers
XP Series
Calibrate per Quality Control plan
Pneumatic Pulse Tools
FLEX, FLEXS Series
PTM-20, PTM-52, PTM-92, PTM- 135, PTM-300 (various torque ranges)
Pneumatic Multipliers
Calibrate every 6–12 months
Service as needed
Automated DC Drivers
CLF Series
Verify torque when adjusting Replace brushes when worn ~50%
Motor/Gear/Grease: inspect/replace at ~1,000,000 cycles · Torque Accuracy: calibrate at ~500,000 cycles · Cable: replace at ~600,000 cycles Motor/Gear/Grease: inspect/replace at ~1,000,000 cycles · Torque Accuracy: calibrate at ~500,000 cycles · Cable: replace at ~600,000 cycles Low-maintenance brushless design; extended life cycle
Current Control Smart Electric (Non-Transducerized)
EC Series, Mini MD Series, MD Series
Calibrate every 6–12 months or per Quality Control plan
Calibrate per Quality Control plan; verify torque via built-in sensor or tool procedure
Transducerized DC Tools
ECT Series, MDT Series
Cordless Transducerized DC Tools
Calibrate per Quality Control plan; verify torque periodically
EPT Series
Calibration Price List
Contact the Mountz Customer Experience Service Team & Schedule Your Calibration Today
https://mountztorque.com/en-us/usa-service
(408) 850-9978
WANT TO VERIFY & CALIBRATE YOUR TOOLS IN-HOUSE?
LTT-Series Torque Analyzer
Validates & calibrates torque screwdrivers, wrenches & power tools Works with built-in and external Mountz sensors Data storage, graphing & USB export
EZ-TorQ III Analyzer
Compact, portable torque tester with built-in transducer Ideal for small hand tools & non-impact power tools Touchscreen interface with Mountz Data Streamer software Quick, on-the-floor tool verification
Screw RDA - Run Down Adapters
Simulates joint conditions for consistent torque readings Attaches between the tool and analyzer transducer For clockwise use; replaceable screw element
AURA - Auto Reversing Run Down Adapters
Automatically resets after each run-down Provides repeatable torque results for power tools Compact, easy to use, and ideal for frequent testing