Indoor Unit Model

rak-18pec

rak-25pec

rak-35pec

rak-50pec

Nominal Cooling Capacity (min - max)

kW kW kW kW kW kW kW

2.00 (0.90 - 2.50)

2.50 (0.90 - 3.10)

3.50 (0.90 - 4.00)

5.00 (1.90 - 5.20)

Sensible Cooling Capacity UK Cooling Capacity (sensible)

1.99

2.28

2.87

3.47

1.9 (1.7)

2.4 (2.0)

3.3 (2.5)

4.2 (3.1)

Heating capacity at -7°C

1.75

2.50

3.00

4.00

Nominal Heating Capacity (min - max) Nominal cooling power input (min - max) Nominal heating power input (min - max)

2.50 (0.90 - 3.20) 0.58(0.25-1.01) 0.62(0.25-0.97)

3.40 (0.90 - 4.40) 0.70 (0.25 - 1.29) 0.88 (0.25 - 1.25)

4.20 (0.90 - 5.00) 1.09 (0.25 - 1.46) 1.10 (0.25 - 1.70)

6.00 (2.2- 7.30) 1.56 (0.50 - 2.10) 1.66(0.50 - 2.75)

Seasonal Efficiency SEER (4)

5.80

5.80

5.85

5.88

Energy Efficiency Class

kWh/yr

A+

A+

A+

A+

Annual Energy Consumption

121 3.80

151 3.80

209 3.80

298 3.80

Seasonal Efficiency SCOP (4) (Average Climate)

Energy Efficiency Class

kWh/yr

A

A

A

A

1,124

1,601

Annual Energy Consumption

316

909

Nominal Load Efficiency EER / COP

3.45/4.03

3.57/3.86

3.21/3.82

3.21/3.61

(5)

Energy Class (Cool/Heat)

A/A

A/A

A/A

A/A

Noise level cooling (sound pressure) (SL / L / M / H) Noise level heating (sound pressure) (SL / L / M / H)

dB(A) dB(A) dB(A) m 3 /h m 3 /h

21/24/33/37 19/22/33/38

22/24/33/40 20/23/34/41

25/26/36/43 26/27/36/44

28/30/40/46 25/30/39/47

(2)

(2)

Noise level (sound power) (1)

51

54

57

60

Air flow cooling mode (SL / L / M / H) Air flow heating mode (SL / L / M / H)

312/350/400/440 312/350/420/480

333/370/430/510 333/400/500/570

333/400/485/600 333/520/550/660

333/450/600/700 433/510/650/770

Dehumidification

l/h

1.2

1.4

1.6

2.0

Dimensions (H x W x D)

mm

280x780x218

280x780x218

280x780x218

280x780x218

Weight

kg

7.5

7.5

7.5

8.0

Power supply

From Outdoor Unit

φ 16mm

φ 16mm

φ 16mm

φ 16mm

Drain diameter (ext)

Std

Infra Red (RAR-5F1) Wired (SPX-RCDB) Wired (SPX-WKT2)

Infra Red (RAR-5F1) Wired (SPX-RCDB) Wired (SPX-WKT2)

Infra Red (RAR-5F1) Wired (SPX-RCDB) Wired (SPX-WKT2)

Infra Red (RAR-5F1) Wired (SPX-RCDB) Wired (SPX-WKT2)

Remote Control

Opt. 1 Opt. 2

Outdoor Unit Model

rac-18wec

rac-25wec

rac-35wec

rac-50wec

dB(A) dB(A) dB(A) m 3 /h

45 46 59

47 48 61

48 49 62

50 50 64

Noise level cooling (sound pressure) (night mode) (3) Noise level heating (sound pressure) (night mode) (3)

Noise level (sound power) (1) Air flow (Cooling / Heating)

1860/1620

1860/1620

1860/1620

2160/2160

Dimensions (H x W x D)

mm

530x660x278

530x660x278

530x660x278

600x792x299

Weight

kg

24.5

24.5

27.5

40.0

Inch mm

1/4 - 3/8 6.35 - 9.52

1/4 - 3/8 6.35 - 9.52

1/4 - 3/8 6.35 - 9.52

1/4" / 1/2" 6.35 - 12.70

Piping diameter (Liquid / Gas)

Minimum Piping Length

m

3.0

3.0

3.0

3.0

Maximum Piping Length / Height Dierence

20/10

20/10

20/10

20/10

m

Current Quantity of Refrigerant

kg

0.72

0.72

0.95

1.25

m / g/m

20/ -

20/ -

20/ -

20/ -

Chargeless / Additional Refrigerant Charge

Power supply

230V/1Ph/50Hz

230V/1Ph/50Hz

230V/1Ph/50Hz

230V/1Ph/50Hz

Recommended fuse size

A A A

16

16

16

25

Starting current (cooling/heating) Running current (cooling/heating)

<1 Amp

<1 Amp

<1 Amp

<1 Amp

1.09-4.39/1.09-4.22

1.09-5.61/1.09-5.43

1.09-6.35/1.09-7.39

2.17-9.13/2.17-11.96

Interconnecting Cables

No.

3 + E

3 + E

3 + E

3 + E

Working Range (cooling/heating)

°C

-10°C~43°C / -15°C~21°C

-10°C~43°C / -15°C~21°C

-10°C~43°C / -15°C~21°C

-10°C~43°C / -15°C~21°C

Refrigerant / GWP Compressor type

R410A / 1975

R410A / 1975

R410A / 1975

R410A / 1975

Rotary

Rotary

Rotary

Rotary

(1)Soundpower level is theA-weightedsoundpower level [dB(A)]measuredatstandard ratedconditions for the “cooling”modeoperation inaccordance toEN12102 (2)Soundpressure level ismeasuredat0.8meterbeneath indoorunit1m fromdischargegrille inanechoicchamber (3)Soundpressure level ismeasuredat1.0m from front faceofunit,1.5mabove theground inanechoicchamber. (4)Datacalculated inaccordance toprEN14825and theCommissionCommunication2012/C172/01 (5)Nominal loadefficiency (Cooling35°C/27°C,Heating7°C/20°C)