VERATHON'S GLIDESCOPE E-BROCHURE

Intubation success in patients with predicted difficult airways is improved by videolaryngoscopy.

“ Designed for rapid , 1 st PASS SUCCESS ”

A Leader in Airway Management For over 20 years, GlideScope® from Verathon has been a trusted leader in airway management, offering innovative solutions in video laryngoscopy, bronchoscopy, and airway visualization. Since introducing the first video laryngoscope in 1999 with Dr. Jack Pacey, GlideScope® has continued to lead the market with a comprehensive range of single-use and reusable video laryngoscopes. These products, designed for both adult and pediatric patients, provide improved laryngeal exposure, reduced lift force on patients, and higher first-pass success rates.

GlideScope® remains at the forefront of the industry with the latest advancements in lighting and camera technology, ensuring proven clinical performance across diverse clinical settings.

FEATURES

BENEFITS

OUTCOME

Better visualization of airway ImprovedOR Coordination

Superior glottic views

GlideScope ® unique 60 o Angulated Blades

Improved Teaching

Reduced cervical spine motion

Less lift force (~2-3 lbs)

Reduced patient trauma Reduced clinician fatigue

Small mouth openings More working room overall Cervical spine immobilization

Low-profile/slim blades

LoProBlades high performance features

 Optimized lighting for airway management  Spectrum SU Blades and Ti Blades

Dynamic Light Control

Reveal ™ Anti-Fog mechanism

Eliminates fogging @ 10-120 seconds

Blade sizes from neonate to large adult Reusable or Single-use blade preference Offering diversity of blade and tool types

Ensures high success rate for first-attempt intubation at any age

Broad portfolio of options

The Efficacy of GlideScope ® VideolaryngoscopyCompared with Direct Laryngoscopy in Children who are Difficult to Intubate. 1

Meta-analysis of RCTs comparing video-assisted laryngoscopy with direct laryngoscopy in patients with predicted or simulated difficult airways report improved laryngeal views, a higher frequency of successful intubations, and a higher frequency of first attempt intubations with video-assisted laryngoscopy (Category A1-B evidence)

The success rate of intubation using a video laryngoscope ranges from 97.4% to 99.6%. 2

1.

British Journal of Anesthesia, 119 (5): 984 – 92 (2017)

2. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635845/#:~:text=The%20incidence%20rates%20of%20difficulty,%25%2C%20respectively%20%5B5%5D.

SOCIETY FOR TECHNOLOGY IN ANESTHESIA Section Editor: Maxime Cannesson

BACKGROUND: Intubation success in patients with predicted difficult airways is improved by video laryngoscopy. In particular, acute-angle video laryngoscopes are now frequently chosen for endotracheal intubation in these patients. However, there is no evidence concerning whether different acute-angle video laryngoscopes can be used interchangeably in this scenario, and would allow endotracheal intubation with the same success rate. We therefore tested whether first-attempt intubation success is similar when using a newly introduced acute-angle blade, that is an element of an extended airway management system (C-MAC D-Blade) compared with a well-established acute- angle video laryngoscope (GlideScope ® ). METHODS: In this large multicentered prospective randomized controlled noninferiority trial, patients requiring general anesthesia for elective surgery and presenting with clinical predictors of difficult laryngoscopy were randomly assigned to intubation using either the C-MAC D-Blade or the GlideScope video laryngoscope. The hypothesis was that first-attempt intubation success using the new device (D-Blade) is no >4%, less than the established device (GlideScope), which would determine noninferiority of the new instrument versus the established instrument. The secondary outcomes we observed included intubation success with multiple attempts and airway-related complications within 7 days of enrollment. RESULTS: Eleven hundred patients were randomly assigned to either video laryngoscope. The first-attempt intubation success rate was 96.2% in the GlideScope group and 93.4% in the C-MAC D-Blade group. Although the absolute difference between the 2 groups was only 2.8%, the 90.35% upper confidence limit of the difference exceeded the predefined margin (4.98%), indicating a rejection of the noninferiority hypothesis for first-attempt intubation success. For attending anesthesiologists, and in cases requiring multiple attempts, intubation success rates did not differ between systems. Pharyngeal injury was noted in 1% of the patients, with no significant difference observed between the intervention groups. CONCLUSIONS: A head-to-head comparison in this large multicenter trial revealed that the newly introduced C-MAC D-Blade does not achieve the same first-attempt intubation success as the GlideScope in patients with predicted difficult laryngoscopy, except when used by attending anesthesiologists. Further research is needed to identify the potential causes for this difference . Intubation success rates were very high with both systems, indicating that acute-angle video laryngoscopy is an exceptionally successful strategy for the initial approach to endotracheal intubation in patients with predicted difficult laryngoscopy. (Anesth Analg 2016;122:740-50) First-Attempt Intubation Success of Video Laryngoscopy in Patients with Anticipated Difficult Direct Laryngoscopy: A Multicenter Randomized Controlled Trial Comparing the C-MAC D-Blade Versus the GlideScope in a Mixed Provider and Diverse Patient Population Michael F. Aziz, MD, Ron O. Abrons, MD, † Davide Cattano, MD, PhD, Emine O. Bayman, PhD, † David E. Swanson, MD, † Carin A. Hagberg, MD, Michael M. Todd, MD,* † and Ansgar M. Brambrink, MD, PhD*

GLIDESCOPE AT A GLIMPSE

TITANIUM CONSTRUCTION For lightweight strength and durability

HI-RES DIGITAL CAMERA - Full color with LED illumination and - Reveal™ anti -fog technology

LOW PROFILE BLADES - For improved maneuverability - 30% thinner than Stats

TRADITIONAL MAC-STYLE BLADE For a wide range of clinical needs

ERGONOMIC HANDLE Designed for added control and comfort

SIGNATURE GLIDESCOPE BLADE ANGULATION - Improves your view of the glottis - Decreases lift force on patient by 55%

Reference: 0270-0858

Description: GLIDESCOPE ® TITANIUM SYSTEM, PREMIUM CART

Inclusion: GlideScope ® Video Monitor (1); Glidescope ® Titanium Video cable (1); Premium cart (1); Glidescope ® Titanium LoPro, Reusable Video Laryngoscope T2 / T3 / T4 or GlideScope ® Titanium MAC, Reusable Video Laryngoscope T3 / T4 (Choose 1 as FOC)

FDA Reg. No.: CDRRHR-CMDN-2022-1061446

Reference: 0570-0368

Description: GLIDESCOPE ® GO ™

MONITOR, VIDEO LARYNGOSCOPE

Inclusion: GlideScope® GO ™ Monitor (1); Power Adapter (1); USB Flash Drive (1).

FDA Reg. No.: CDRRHR-CMDN-2021-874717

REUSABLE

0574-0119

Reference: 0574-0119

Description : GlideScope® Titanium LoPro, Re-usable Video Laryngoscope T2 1s Inclusion: Blade only

FDA Reg. No.: CDRRHR-CMDN-2022-890087

0574-0147

Reference: 0574-0147

Description : GlideScope® Titanium LoPro, Re-usable Video Laryngoscope T3 1s Inclusion: Blade only

FDA Reg. No.: CDRRHR-CMDN-2022-890087

0574-0148

Reference: 0574-0148

Description : GlideScope® Titanium LoPro, Re-usable Video Laryngoscope T4 1s Inclusion: Blade only

FDA Reg. No.: CDRRHR-CMDN-2022-890087

0574-0149

Reference: 0574-0149

Description : GlideScope® Titanium MAC, Re-usable Video Laryngoscope T3 1s Inclusion: Blade only

FDA Reg. No.: CDRRHR-CMDN-2022-875228

0574-0150

Reference: 0574-0150

Description: GlideScope® Titanium MAC, Re-usable Video Laryngoscope T3 1s Inclusion: Blade only

FDA Reg. No.: CDRRHR-CMDN-2022-875228

REUSABLE with SINGLE-USE

Reference: 0270-0970

Description: GLIDESCOPE® VIDEO BATON 2.0 LARGE (3-4) KIT Inclusion :Video Baton (1); GVL Stat 3 (1); GVL Stat 4 (1); Smart cable (1); Cradle for Video Baton (1)

SINGLE-USE

Reference: 0574-0166

Reference: 0574-0201

Reference: 0574-0194

Reference: 0574-0165

Reference: 0574-0195

Description: GLIDESCOPE ® SPECTRUM™ LOPRO, SINGLE-USE VIDEO LARYNGOSCOPE S2

Description: GLIDESCOPE ® SPECTRUM™ LOPRO, SINGLE-USE VIDEO LARYNGOSCOPE S2.5

Description: GLIDESCOPE ® SPECTRUM ™ LOPRO, SINGLE-USE VIDEO LARYNGOSCOPE S3

Description: GLIDESCOPE ® SPECTRUM™ LOPRO, SINGLE-USE VIDEO LARYNGOSCOPE S1

Description: GLIDESCOPE ® SPECTRUM ™ LOPRO, SINGLE-USE VIDEO LARYNGOSCOPE S4

I nclusion: Blade only (Box of 10s)

I nclusion: Blade only (Box of 10s)

I nclusion: Blade only (Box of 10s)

I nclusion: Blade only (Box of 10s)

I nclusion: Blade only (Box of 10s)

FDA Reg. No. :CDRRHR- CMDN-2022-892987

FDA Reg. No.: CDRRHR- CMDN-2022-892987

FDA Reg. No. :CDRRHR- CMDN-2022-892987

FDA Reg. No.: CDRRHR- CMDN-2022-892987

FDA Reg. No. :CDRRHR- CMDN-2022-892987

Reference: 0574-0203

Reference: 0574-0202

Reference: 0574-0187

Reference: 0574-0188

Description: GLIDESCOPE ® SPECTRUM™ MILLER, SINGLE-USE VIDEO LARYNGOSCOPE S0 I nclusion: Blade only (Box of 10s)

Description: GLIDESCOPE ® SPECTRUM™ MILLER, SINGLE-USE VIDEO LARYNGOSCOPE S0 I nclusion: Blade only (Box of 10s)

Description: GLIDESCOPE ® SPECTRUM ™

Description: GLIDESCOPE ® SPECTRUM ™

DIRECTVIEW ™ MAC, SINGLE-USE VIDEO LARYNGOSCOPE S3 I nclusion: Blade only (Box of 10s)

DIRECTVIEW ™ MAC, SINGLE-USE VIDEO LARYNGOSCOPE S4 I nclusion: Blade only (Box of 10s)

FDA Reg. No.: CDRRHR- CMDN-2022-881801

FDA Reg. No.: CDRRHR- CMDN-2022-881801

FDA Reg. No.: CDRRHR- CMDN-2022-885854

FDA Reg. No.: CDRRHR- CMDN-2022-885854

SINGLE-USE

0800-0608

Reference: 0800-0608

Description: GLIDERITE ® SINGLE-USE STYLET - LARGE, 1s Inclusion: Stylet only (box of 10s) FDA Reg. No.: CDRRHR-CMDN-2022-893012

0800-0654

Reference: 0800-0654

Description: GLIDERITE ® SINGLE-USE STYLET - MEDIUM, 1s Inclusion: Stylet only (box of 10s) FDA Reg. No.: CDRRHR-CMDN-2022-893012

0803-0118

Reference: 0803-0118

Description: GLIDERITE ® SINGLE-USE STYLET - SMALL, 1s Inclusion: Stylet only (box of 10s) FDA Reg. No.: CDRRHR-CMDN-2022-893012

OTHERS SKUs (SINGLE-USE)

Reference: 0574-0104

Reference: 0574-0026

Reference: 0574-0027

Reference: 0574-0110

Reference: 0574-0100

Reference: 0574-0101

Description: GLIDESCOPE ® GVL ® Stat, Single-use 0

Description: GLIDESCOPE ® GVL ® Stat, Single-use 1

Description: GLIDESCOPE ® GVL ® Stat, Single-use 2

Description: GLIDESCOPE ® GVL ® Stat, Single-use 2.5

Description: GLIDESCOPE ® GVL ® Stat, Single-use 3

Description: GLIDESCOPE ® GVL ® Stat, Single-use 4

Inclusion: GVL only (Box of 10s)

Inclusion: GVL only (Box of 10s)

Inclusion: GVL only (Box of 10s)

Inclusion: GVL only (Box of 10s)

Inclusion: GVL only (Box of 10s)

Inclusion: GVL only (Box of 10s)

FDA Reg. No.: CDRRHR-CMDN-2022- 882356

FDA Reg. No.: CDRRHR-CMDN-2022- 882356

FDA Reg. No.: CDRRHR-CMDN-2022- 882356

FDA Reg. No.: CDRRHR-CMDN-2022- 882356

FDA Reg. No.: CDRRHR-CMDN-2022- 882356

FDA Reg. No.: CDRRHR-CMDN-2022- 882356

ACCESSORIES

Reference: 0600-0616

Description; GLIDESCOPE ® TITANIUM VIDEO CABLE 1s Inclusion: Video Cable only

FDA Reg. No.: CDRRHR-CMDN-2022-888093

Reference: 0800-0544

Description: GLIDESCOPE ® TITANIUM SPECTRUM SMART CABLE Inclusion: Spectrum Smart Cable only

FDA Reg. No.: CDRRHR-CMDN-2022-887997

Reference: 0570-0338

Description: GLIDESCOPE ® VIDEO MONITOR Inclusion: GlideScope® Video Monitor Only

FDA Reg. No.: CDRRHR-CMDN-2022-949506

Reference: 0800-0537

Description: PREMIUM CART FOR GVM MONITOR Inclusion: Premium Cart

FDA Reg. No.: CDRRHR-CMDN-2022-1061446

ACCESSORIES

Reference: 0800-0566

Description: GLIDESCOPE ® GO™ LARGE CARRYING CASE

Reference: 0570-0373

Description: GLIDESCOPE ® GO™ POWER ADAPTOR KIT

Reference: 0570-0372

Description: GLIDESCOPE ® GO ™ CHARGING CRADLE 1s

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10

Made with FlippingBook Digital Publishing Software