1122 Laurel Ave - Digital Brochure $215,000

Report Rating Key ( Where there are multiple rooms to a category, the Evaluator must specify the room to which a Comment is related )

H: Hazardous Condition

B: Below Minimum

C: See Comments NV: Not Visible

M: Meets Minimum NA: Not Applicable

Requirements N: No

Requirements

Y: Yes

CITY OF SAINT PAUL TRUTH-IN-SALE OF HOUSING REPORT

Zoning District: R4 Date of Evaluation: Feb 27, 2017 Address: 1122 LAUREL AVE Present Occupancy:

Client Name: DENISE JACKSON Owner: Denise A Jackson File Number: File#: 17-014830

Client Contact: 20 RAVEN FALLS LANE ,SIMPSONVILLE,SC 29

Number of Units Evaluated: Single Family Dwelling

Evaluator Contact: Work: 651-455-5888 gusbas@aol.com Evaluator Name: Mike Moser M. J. Moser

Basement/Cellar

1. Stairs and Handrails

B

B - Handrail(s): improperly installed. lacks guardrail,landing too small

2. Basement/Cellar Floor

M M

3. Foundation

4. Evidence of Dampness or Staining 5. First Floor, Floor System

Y

C - Stains evident

M M

6. Beams and Columns

Electrical Services 7a. Number of Electrical Services 1 7b. Amps 100 7c. Volts 240 Basement Only 8. Electrical service installation/grounding H

H - Extension cord(s) used in lieu of permanent

H - Improper grounding of electrical system.lacks jumper at meter , wate rmeter buried in dirt.

9. Electrical wiring, outlets and fixtures

M

Plumbing System

10. Floor drain(s) (basement) 11. Water and vent piping (all floors) 12. Water piping (all floors)

M M

B

B - Saddle type connections at laundry

13. Gas piping (all floors)

M M M M

14. Water heater(s), installation 15. Water heater(s), venting

16. Plumbing fixtures (basement)

Heating System(s) The Evaluator is not required to operate the heating plant(s) except during the heating season, between October 15 and April 15. 17a. Number of Heating Systems 1

1122 LAUREL AVE

Feb 27, 2017

Page # 3

Evaluator: Mike Moser M. J. Moser

Page 25 of 32

www.redfin.com