T9074-AS-GIB-010/271 Rev 1
Enter the information specified below in the corresponding blocks on the test record. NOTE: Numerical entries to be entered in decimal form, to the nearest 0.001 inch. BLOCK ENTRY 1 Enter the component number (i.e. flask no., URO MRC site etc.). 2 Enter the identification or joint number. 3 Enter the joint configuration. 4 Enter the technical work document, (i.e., TWD, FCP, CWP). 5 Enter the Hull Number. 6 Enter the material type (e.g., HY 80, HSS, etc.). 7 Enter the procedure identification number, revision and change number. 8 Enter the frame number; check either port or starboard for the side of the ship. 9 Scan surface (check applicable block, inside diameter or outside diameter). 10 Enter the instrument manufacturer. 11 Enter the instrument model number. 12 Enter the instrument serial number. 13 Enter the instrument qualification expiration date. 14 Enter the type of couplant used. 15 Enter the serial numbers of calibration standards used (blocks 1 through 4 provided). 16 Enter the indication number from the original inspection report. 17 Enter the distance from “A” or other specified location. 18 Enter the distance from “B” or othe r specified location. 19 Enter the length of the indication. 20 Enter the minimum depth. 21 Enter the maximum depth. 22 Enter the amplitude of indication in percentage of screen height. 23 Enter the beam direction. 24 Enter the serial number, beam angle, size, and frequency. 25 Enter the leg of the sound beam the defect was located. 26 Enter the serial number, size, frequency of longitudinal transducer. 27 Enter the depth measured to indication if detected, or N/A. 28 Enter the amplitude of the indication if detected with longitudinal transducer, or N/A (% DAC or db’s over DAC). 29 Check a block to indicate the longitudinal scan characterization as volumetric or planar. 30 Enter the serial number, size, frequency of shear transducers. 31 Enter the amplitude from the forward beam direction (% DAC or db’s over DAC). 32 Enter the amplitude from the aft beam direction (% DAC or db’s over DAC). 33 Enter the echo dynamics (ED) results (SM for smooth, MP for multiple peaks). 34 Enter the skew results (RD for rapid drop, CEA for constant echo amplitude). 35 Enter the Orbit results (SAD for significant amplitude difference, CEA for constant echo amplitude). 36 Check a block to indicate the shear characterizations as volumetric or planar. 37 Check a block to indicate the 30-70-70 (WSY 70) evaluation as yes/no for whether it is ID connected. 38 Check the appropriate blocks if volumetric reflector for the characterization summary. 39 Check the appropriate blocks if planar reflector for the characterization summary. 40 Enter the serial number, size, frequency of sizing transducers. 41 Enter if AATT or rapid drop (RD) techniques used for data collected. 42 Enter the top depth measured. 43 Enter the bottom depth measured. 44 Enter the height (through wall dimension). 45 Enter remarks, notes and sketches (sign, badge, & date entries). 46 Enter the actual wall thickness of the part. 47 Enter the length or area requested. 48 Enter the length or area inspected. 49 Check a block to indicate whether it is ID connected. 50 Enter the height (through wall dimension). 51 Enter the remaining ligament to the Top or OD surface. 52 Enter the remaining ligament to the Bottom or ID surface. 53 Enter the Inspector’s name , print and sign; enter certification level. 54 Enter the Inspector’s code or Dept. 55 Enter Inspector badge or ID number 56 Enter the Inspection date. 57 Enter the Independent UTCS Test Examiner’s name , print and sign; enter certification level. 58 Enter the Independent UTCS Test Examiner’s code or Dept. 59 Enter Independent UTCS Test Examiner’s badge or ID number 60 Enter the Independent UTCS Test Examiner’s review date.
B-7/(B-8 blank)
Made with FlippingBook - Share PDF online