TBA - NAVSEA TECHNICAL PUBLICATION

S9074-AR-GIB-010/278

TABLE IV. Preheat and interpass temperature for welded ferrous alloys. - Continued

Material group number

Material identification

Minimum preheat temperature °F 1/ , 2/ , 3/

Maximum interpass temperature °F

Supplementary provisions for preheat and interpass temperature

High alloy steel martensitic

400

-

For all S-6 materials except as permitted below

300

500

For 410 welded with 410NiMo For 410 welded with 410NiMo unless otherwise permitted below

200

500

S-6 5/

60 4/

500

For 410S welded by SMAW with 410NiMo, with 0.03% C maximum, or when using GMAW or GTAW for 410S with 410NiMo filler material

High alloy steel maternsitic

200

500

For all S-6A material except as permitted below

60 4/

500

For thickness less than 1.5 inches; and SMAW with 410NiMo electrode with 0.03% C maximum or when using GTAW or GMAW and 410NiMo filler material. Preheat is not mandatory - The preheat and interpass

S-6A

High alloy steel ferritic

-

-

temperature used in qualifying the welding procedure shall be am essential element of that procedure, to be applied in production welding Preheat and interpass temperature shall not exceed 350°F for all S- 8 materials except as provided for in footnote 2.

S-7

High alloy austenitic steel

-

350

S-8

See footnotes at end of table.

Original 56

Made with FlippingBook - Share PDF online