9.3.2.2 Partial Penetration Joints. Where partial penetration welded joints are required, the weld shall be sized to develop the strength required by the design.

9.3.2.2.1 For class M-2 and class A applications, the thickness limitations of MIL-STD-22 do not apply.

9.3.2.2.2 Joints within the same design group may be interchanged without drawing changes provided weld joint efficiencies are not reduced.

9.3.2.2.3 Full penetration joint designs may be used where partial penetration joint designs are specified provided the required joint efficiency is maintained. When this is done, the inspection requirements for the partial penetration joint design apply.